• High quality All Aluminum Alloy Conductor(AAAC) System 1
  • High quality All Aluminum Alloy Conductor(AAAC) System 2
High quality All Aluminum Alloy Conductor(AAAC)

High quality All Aluminum Alloy Conductor(AAAC)

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
10000 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

All Aluminum Alloy Conductor(AAAC)


High quality All Aluminum Alloy Conductor(AAAC)


Introduce


This section deals with heat-treatable magnesium silicon type aluminium alloys to the applicable International Standard, the electrical and mechanical properties of which all fall within the values suggested by relevant standard.Conductors to all other recognized specification can also be supplied. The alloys referred to have higher strength but lower conductivity than pure aluminium. Being lighter,alloy conductors can sometimes be used to advantage in place of the more conventional ACSR; Having lower breaking loads than the latter,  their use becomes particularly favourable when ice and wind loading are low.


Bare homogeneous AAAC is concentric-lay-stranded consisting of aluminium alloy wires wrapped helically around a central aluminium alloy wire. It is similar in construction and appearance to AAC conductor.

AAAC conductor has many advantages. For example, higher strength to weight ratio than AAC conductor, better corrosion resistance than ACSR conductor, lower power losses than equivalent aluminium layer conductor, more simple accessories.

The aluminium alloy stranding consists of 7, 19, 37, 61 and 91 wires.


Application

AAAC is extensively used in overhead electric power transmission and distribution lines which required suitable mechanical strength and electrical conductivity.


AAAC is suitable for the long spans network.


Manufacturing Standard

GB/T 1179-2008, IEC 61089, EN 50182, DIN 48201 Part 6, BS 3242, ASTM B399, NF C 34-125


Introduction of our company


Our company  is a professional China Wire and Cable Manufacturers, mainly supply Aerial bundled cable,House Electric Wire, Insulated Overhead Cable,Aluminium Conductor Steel Reinforced, PVC Control Cables,XLPE Power Cables,BV Electric Wires,Nylon Sheathed Cable,Buried Cable,High Voltage Cable,House Electric Wire,Single Core Flexible Copper Cable,Civil Wire And Cable etc. series of wire and cable products, sincerely welcome everyone to visit.





Q:Decoration when the purchase of water pipes, wires and other items included in the account
KVV is the control cable, generally do industrial control; and RVS is twisted pair, generally used for weak system, to eliminate the interference requirements of the occasion, such as two-wire bus system, specifically, the electrical fire bus more Such as RS485 bus and so on.
Q:What brand of cable is good, what are the top ten brands of wires?
Mainly to distinguish the ground which is the ground, the color of the ground is generally yellow-green; wire two is the fire line L and zero line N, no ground wire, look at the plug on the LN mark, the corresponding good.
Q:I would like to ask my new workshop power consumption of about 500KW, injection molding machine, 60KW . 40KW . 20KW . the other 20KW, how much should the wire? Respectively how to use lines and switches more
A very practical proposal: to your local talent market, a large job fairs, and the best and your professional relevance, to see, look at what positions, pay how? You can also chat with hr, you will understand.
Q:Apple 6splus charge may not support this accessories how to do more
When the lighting circuit and the power circuit shared ladder, BV line is not allowed to put in the ladder, so it is recommended to use the wiring of the lamp ZC-YJV-3 * 2
Q:How to determine how much wire and cable should be used, the current load and how the corresponding wire, such as 4BV, under what circumstances, YJV240 what circumstances, the load is much more
The second floor of the formula is correct, my space also have this formula, with armor and no armor in the current no difference, there are differences in the installation, usually buried to armor, overhead or bridge without armor, you give the model is not Armor, YJV-4 * 240 without armor, YJV-22-4 * 240 armor,
Q:Wire and cable fire resistance to meet what standards, which can provide about, thank you!
Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...............
Q:Why does the bird stand on the wire without anything, but if people touch it,
Is not the home of the bus box? Generally put a cat, a router, a power outlet, two transformers, the other is the network cable and telephone, the key space to be enough
Q:Wire and cable model ZD what does it mean
Wire pipe water problem: In fact, this problem is very serious, then this line should be scrapped or replaced, if you continue to reluctantly use not only to bring you the safety of trouble and the insulation of the wire dropped sharply! Because there is water it will lead to internal leakage can also make the wire heat caused by wire burning and trivial trivial accident, so be sure to take the necessary replacement! Supplement: the wire out of all, with the wire to grab the absorbent gauze and the like back to the twitching, many times for the gauze to dry the water, hair dryer toward the tube to heat the tube to dry and then re-layout of the new line.
Q:Apple 6 Charging Why always show this cable has not yet been certified
And I answered the other person's question is very similar: . the line of the banding distance of not more than 1.2 meters, the two ends of the wire box outlet tube 15CM should be ligation; . casing embedded, then through the basement wall, the surface must be installed rigid Waterproof casing, that is, steel pipe + water ring; through the fire pool, living pool: flexible waterproof casing; (wing ring specific practices can be collected online related Atlas); through the floor, according to whether the design requirements , Under normal circumstances PVC casing on it. Note: . rigid waterproof casing, flexible waterproof casing is a one-time reserved in place, through the floor of the casing of the flower lamb to suppress the barge of Xi Jie Xi Xi shou, is the first stay hole, when the installation of riser Casing, because the floor casing has every layer, the location of the reservation will always be biased, in order to ensure vertical vertical pipe, and finally unified hanging line repair hole and then install the riser and casing. . now most of the bathroom are dirty, waste and diversion, and more of the riser, and so on, the air conditioning casing of all the shear wall should be embedded, to avoid the subsequent damage to the structure of drilling (no stay can only drill) Note that the location of the hole and the installation of the riser will affect the opening of the toilet window. . the casing is the casing, riser is the riser, casing than the riser model 1 to 2 level. . plate at the end of flat, board 2 to 5CM higher to see if you need to do leveling layer.
Q:IPhone6 This cable or accessories have not been certified how to solve
The color is easy to distinguish. General yellow on behalf of the video line, red white plug left and right audio.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords