High Medium Voltage Drive 11KV 500KW RMVC4000-A110/630 VFD

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
100000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Energy-saving Solutions for Enterprise
1
Program Overview
Saving energy achieves 10% -70%
The enterprises do not need to pay for expense of equipment manufacture and installation.
Enterprises only need to pay the saving electricity expense to our company according to the actual quantity of energy saving after the equipments put into operation.
According thousands of the projects’ implementation experiences, such projects recover the investments in three or four years. (Equipment service life is 15 years)
Our company will no longer charge the saving electricity expense after recovering the investment.

The significance of the program:
1
)、Concentrate on solving problems of energy conservation, make enterprises’ energy-saving work reach new level and take their social responsibility
2
)、Avoid the enterprises reactive power fine of low power factor caused by electric energy using (according to Ministry of Electric Power and Water Resources, State Price Control Bureau establish the " measures of power factor adjustment expense ").
3
)、Avoid the high-energy consumption enterprises are implemented differential prices because of the changes of national power regulation.
4
)、For the standard-conforming large-scale (saved energy equal 10 thousand tons standard coal or more) energy-saving technological transformation projects, China will reward the enterprises for energy saving which based on the "Financial Incentives Interim Measure for Energy-saving Technological Transformations" established by Ministry of Finance, the National Development and Reform Commission.( Amount of 200 yuan / ton of standard coal).
5
)、Equipments recovery period is generally 3-4 years, each period payment equal to the amount of current energy-saving benefits, and equipments service life are 15 years, so enterprises will gain huge energy-saving benefits.


2
Implementation Process
Energy Audit
Energy Saving Program Design
Construction Design
Equipments Manufacture
Construction and installation
Maintenance and Repair
Energy Monitoring and Efficiency Insurance
Recovery of Program Investment


3
Program Features
High energy-saving efficiency
The project saving rate is generally 10% -30%, highest is up to 70%.
Clients Zero Investment
All works of design, audit, manufacturing, construction, monitoring are handled by RXPE, clients does not require investment.
Energy-saving Guarantee
RXPE promises the amount of energy saving, ensuring that clients’ cost reduction immediately.
Short Investment Recovery Period
The investment recovery period is short, average period is 3-4 years.
Low Risk
Customers do not input large sums of money also can enjoy professional energy-saving products, technologies and services, and the investment risk is very low.
Improvement of Cash Flow
Customers with the support of RXPE approve energy-saving program to improve cash flow, invest the limited funds into other priority investment areas.
Enhance competitiveness through implementing energy conservation, improving energy-saving efficiency, reducing energy costs and enhancing the quality of environment, establish green corporate image and enhance market competiveness.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Will the motor suddenly stop when the inverter is suddenly powered down?
Generally in the absence of external brake or brake case, if the power, the motor is in a free stop state, uncontrolled,will gradually slow down to 0
Q:What is the working principle of high voltage electrodes and frequency converters?
High-voltage inverter is the input power supply voltage above 3KV high-power inverter, the main voltage levels are 3000V, 3300V, 6000V, 6600V, 10000V and other voltage levels of high-voltage high-power inverter High voltage inverter from high - low - high; low - high; high - high points.
Q:On the notebook power adapter output current and voltage issues
On the real virtual cable that adapter is rectifier filter output, no regulator, the notebook internal regulator, the adapter does not need to regulator. 3.25A is smaller than 4.5A, because the adapter has a power margin that can be used. Summer attention to touch the adapter surface is overheating. Conditional or buy a large number of good current.
Q:Laptop power adapter how to detect?
After opening to see what is burned, Estimated to be insurance and the like
Q:Inverter alarm a043, how is it
When there is a signal failure, if necessary, use DTI Board, if necessary, change P215 In addition, for the synchronous motor (P095 = 12): the inverter is released until the motor is at rest
Q:How to disassemble the notebook power adapter
4, between the shield and the circuit board is also separated by a layer of thick plastic film, and then cut off the knife after the United States, you can see the circuit board "Lushan true"
Q:Three-phase two-pole motor can be used to reduce the frequency of the inverter
Speed range adjustable, you can drop to any speed you want!
Q:Does the inverter set the number of poles to match the number of poles of the motor?
Variable-frequency (VFD) is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment. The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on.
Q:Inverter with 2.2KW 6 pole motor. 1 minute 8 times reversing often burn the motor, how to solve. For the 2 pole 4KW motor is the same.
1. Change to servo drive and servo motor. Should be frequent no problem. 2. Or in the machinery to find a way to let it repeatedly change.
Q:The Schneider inverter reports the nlp command
1, the inverter control circuit with an external 24V power supply, the main circuit did not power 2, PO and PA between the short film can not cause this failure.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range