Product Description:

Specifications

1.wide working voltage:38-96v
2.can be directly connected to solar panel
3.built-in MPPT,can make the best use of solar energy

Head:
100M
Flow:
20T/H
Voltage:
48V DC
Power:
7200W
Package Size:
1880*160mm
Weight:
55kg
Intake:
140mm
Outlet:62mm

  • By CE Certification

  • DC input, wide voltage(working voltage:38V-96V)

  • Built-in MPPT which can make the best use of the solar energy.

  • The pump can be directly connected to solar panels in sunshine without controller.

  • The pump include Over-voltage protection / Under-voltage protection / Over-current protection / Over-load protection.

  • Environmental protection, achieve zero carbon dioxide emissions.

  • Solved the water shortage problems of the area without electricity

  • Tank/Cistern filling

  • Village or family water supply

  • Water supply for farm

  • Garden/courtyard irrigation systems

  • Livestock watering

  • Swimming pool filling

  • Fountains

  • Water supply for bivouac or camping car

  • Solar water circulating system

  • Renewable energy projects

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Pump operator's responsibility Sharing the rules, responsibilities, etc..
3. master the operating rules of the pump operation, and make sure the pump position is reasonably determined. Do a good job of site investigation, find out, pay attention to.4. master the working principle and basic technical parameters of the delivery pump. Obey the command of production dispatcher to ensure the completion of production tasks.5., according to the number of tanker at the scene, determine the pumping speed, in order to ensure the continuity of pouring.6. normal pumping, the discharge rate should be uniform, to prevent uneven discharge, resulting in pressure pipe gas plug, and thus lead to pipe or pipe explosion accident.
Q:Is the centrifugal pump large or small?
NPSH is also called cavitation, cavitation is too big to be.3, pump the liquid when working in the impeller inlet will produce vapor due to a certain vacuum pressure, vaporization of the air bubbles in the liquid particle movement under the impact of erosion on the impeller, the metal surface, thus undermining the impeller and other metal, then vacuum pressure is called vaporization pressure, NPSH is excess vaporization pressure of surplus the energy position of the unit weight of the liquid in the pump suction port of. The unit with annotation, (NPSH) r with. The absorption process is necessary NPSH H: pump suction fluid allows the vacuum pump installation height is allowed, in meters.
Q:What is cavitation, centrifugal pump cavitation phenomenon how to solve?
The pump is in operation, if the over-current part of the local area (usually the impeller blade inlet somewhere later) for some reason, the absolute pressure of pumping the liquid was reduced to liquid vapor pressure temperature, liquid vaporization began in the area, produce a lot of steam, forming bubbles, when the liquid contains a lot of bubbles forward by high pressure impeller zone, high pressure liquid around the bubbles in the bubble decreases drastically and rupture. Condensation in the bubble burst at the same time, the liquid particle filled hole at a high speed, this moment has a very strong effect of water hammer, and with a high impact frequency against the metal surface, the impact stress of hundreds to thousands of atmospheric pressure, impact frequency can be up to tens of thousands of times per second, serious breakdown when the wall thickness will be.The process of cavitation in a pump is caused by the bursting of bubbles and bubbles in the water pump and the destruction of the over-current components. Water pump cavitation, in addition to the over-current components will have a destructive effect, but also noise and vibration, and lead to the performance of the pump down, seriously when the pump will be interrupted liquid, can not work properly.
Q:What are the reasons for sealing damage of centrifugal pumps?
Two, cavitation. Cavitation (mainly from a thermal centrifugal pump).Because the medium is hot water, the water temperature is too high to produce steam, the gas in the pipeline enters the pump cavity height, and the part of the gas can not be discharged, thus causing water shortage to run, the machine seal dry grinding is invalid, and the cavitation erosion device is not available.Process: replace the machine seal.
Q:What are the causes of pump shock?
3. the water pump set screws loose, adjust the concentric, fastening the foot4. pump into foreign body, open cover overhaul5. the flow is too large or too small, adjust the equipment to control the water output
Q:How many kinds of pumps are available and the operating principles of various pumps?
The volume type pump, depending on the periodic change of sealing liquid containing space volume, the energy is periodically transmitted to the liquid, the liquid pressure increased to force the liquid discharge, according to the motion form of work elements can be divided into reciprocating pump and rotary pump. Other types of pumps transmit energy in other forms. As the jet pump work on high-speed jet of fluid will be required to transport fluid suction pump after mixing for momentum exchange in order to transfer energy; water hammer pump by water when braking in the flow of energy transfer is to rise to a certain height; the electromagnetic pump is energized to make the liquid metal in the electromagnetic forces generated in the flow and transport. In addition, the pump can also be classified according to the nature of the transmission fluid, driving methods, structure, use and so on.
Q:Does the reservoir water heater press the booster pump (high marks)?
The outlet water pressure of hot water is the same as that of cold water. The water heater is pushed by cold water to push out the hot water. (of heating). Installation location about 2 meters away from the ground, the impact of water pressure is not large, in rural areas, the installation position in more than two buildings will have an impact. In the city, the installation position is above four floor to affect the water pressure.
Q:How to select hydraulic pump?
1. rpmOperating speed is the actual rotation speed of a pump (or motor) at work.Rated speed is the maximum speed that can operate normally for a long time under rated pressure. If the pump exceeds the rated speed, the work will cause insufficient oil absorption, vibration and noise, the parts will suffer cavitation damage, life expectancy.Minimum steady speed is the minimum speed allowed for normal motor operation. At this speed, the motor does not appear crawling phenomenon.
Q:Why is the sewage pump device coupler?
Automatic coupling installation of sewage pump is a sewage pump with automatic coupler and a guide rod guide chain fixed installation, convenient maintenance, manual maintenance can be directly hung up by the pump coupling device, ordinary sewage pump is generally Mobile
Q:Why do we need to stop the pump?
And the pump at the start, if the valve opening pump, then the pump outlet pressure (head) is very small, so the pump flow will be great, the pump power is very large, causing the start-up current is very large. In addition, the starting current of the motor itself is also very large. These two factors add up to the possibility of overloading the motor, resulting in failure to start or even burn the motor.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range