1.Description

Grade 4245G is specially used for 10kv below aerial hanging power cable, it is composed by 90% silane crosslinkable low density polyethylene (compound A) and 10% black catalyst (compound B). The product’s major characteristics are

◆Outstanding anti-ageing property

◆Low heat shrinkage rate

◆Wide range of processing temperature, simple processing technique.

◆Suitable for tubing style extrusion mould.

Standard

After crosslinked in the tepid water, the cable made from the product grade 4245G can comply with the standard of IEC60502-2004, GB/T14049-2008

2.Specification


Type

Density g/cm3

Elongation at Break %

Tensile Strength MPa

Hot Set Elongation(200°C15min 0.2Mpa)

Load Elongation

Permanent change in rate after cooling

Monosil method

Y101

0.92

620

21.5

60

-2.5

Sioplas method

101A

0.92

610

22.0

50

0

Sioplas method

101B

0.92

720

24.5

65

-5.0

Sioplas method

101C

0.92

595

22.5

50

-2.5

Low thermal shrinkage

101T

0.92

590

23..0

50

-2.5

High temperature resistant

101H

0.92

600

24.5

55

-2.5

Self-crosslinkable

101Z

0.92

390

19.0

40

-2.5

Self-crosslinkable of monosil method

Y101Z

0.92

500

22.0

40

-5.0

3.Major characteristics

1. Extremely low heat shrinkage rate, which can solve the disqualified cable shrinkage problem in the past.

2.Cables made from the product have excellent performance in smooth cable surface, high extrusion speed and production efficiency.

3. The processing temperatures for the product are comparatively low, which can save the energy and reduce the cost.

4. Initial melt point 113°C, final melt point 123°C.

5. Density 0.923±0.02g/cm3

4.Picture

Q:What are the varieties of wire and cable (detailed point)
Cable regardless of the definition of the number of elements in the definition of a few such as: YJV-3 * 50 + 1 * 16 calculated the number of lines is always a different, different wire rules Model input: bv-2 * 2.5 / bv-3 * 4 (different material), bv-2 * 2.5 + 3 * 4 (the same material)
Q:What brand of cable is good, what are the top ten brands of wires?
If you are talking about the three-core wire, black - ground brown - line of blue - zero line. If it is 3 plugs, your wire is only 2 lines. Then the yellow received L, black received N. The above is the ground wire.
Q:What is the difference between "wire" and "cable"?
Simple point, the plotter is generally used to out of the line map, the general is the Academy of Engineering, the Bureau of the use of a CAD map, and some can also be some effect of the general effect of the map, generally suitable for color requirements are not very high, but right Print accuracy requires a high place. Inkjet machine can be divided into indoor and outdoor ink, outdoor irritating smell, for outdoor advertising like the effect of the map, the indoor no irritating smell, the general subway, as well as other indoor advertising are used this out of
Q:Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
This is too difficult to give you a way to just try: with a fine wire rope, that is, lift the clothes on the stick so thick, the end of a bend, with a tape wrapped around the head, try can not wear, wear When the possibility of rotating wire rope, if you can go through the success of the half, the key is to use the wire through the more difficult, can only use the cord, hard-line 100% make life difficult.
Q:How to determine how much wire and cable should be used, the current load and how the corresponding wire, such as 4BV, under what circumstances, YJV240 what circumstances, the load is much more
Can not be removed, and so on after the first line of fluoride, and then demolition of air conditioning.
Q:Remove the computer and wash it off. What the motherboard did not move it, that is, the dust of those dust sasses, as well as the other wire of the skin what Sassafras wash, but the computer re-connected to the Internet when the old mistakes . and the lower right corner of the red Fork appears, disappeared after the emergence. The The Said the network cable is not plugged in, but the MODERN that POWER, LINK, LINE, 3 lights are normal display. The The This is how the matter, and just also appeared keyboard and mouse just start the machine can also be used normally, but in a moment to fall, and then plug their plug re-plug the mouse lights can be displayed, but the lights on the keyboard simply do not Bright, restart the computer but good, what is going on? bother. The The I hope the master quickly to help me, and this machine is relatively old ah No problem added: on a machine, just tried to re-create a connection in the network neighborhood, useless more
Galvanized itself on the anti-corrosion, no need to do anti-corrosion treatment.
Q:Wire and cable fire resistance to meet what standards, which can provide about, thank you!
Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...............
Q:Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
At the same time, security monitoring line itself is a weak line
Q:Wire and cable model ZD what does it mean
Put the water clean, with a table to measure the insulation resistance between the lines, as long as no less than 1.5-2 can.
Q:Apple 6 Charging Why always show this cable has not yet been certified
And I answered the other person's question is very similar: . the line of the banding distance of not more than 1.2 meters, the two ends of the wire box outlet tube 15CM should be ligation; . casing embedded, then through the basement wall, the surface must be installed rigid Waterproof casing, that is, steel pipe + water ring; through the fire pool, living pool: flexible waterproof casing; (wing ring specific practices can be collected online related Atlas); through the floor, according to whether the design requirements , Under normal circumstances PVC casing on it. Note: . rigid waterproof casing, flexible waterproof casing is a one-time reserved in place, through the floor of the casing of the flower lamb to suppress the barge of Xi Jie Xi Xi shou, is the first stay hole, when the installation of riser Casing, because the floor casing has every layer, the location of the reservation will always be biased, in order to ensure vertical vertical pipe, and finally unified hanging line repair hole and then install the riser and casing. . now most of the bathroom are dirty, waste and diversion, and more of the riser, and so on, the air conditioning casing of all the shear wall should be embedded, to avoid the subsequent damage to the structure of drilling (no stay can only drill) Note that the location of the hole and the installation of the riser will affect the opening of the toilet window. . the casing is the casing, riser is the riser, casing than the riser model 1 to 2 level. . plate at the end of flat, board 2 to 5CM higher to see if you need to do leveling layer.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords