Gel Technology Battery Ares(OPzV) Series 8OPzV 800

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
5000000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:


Gel Technology Battery Ares(OPzV) Series Introduction

Ares(OPzV) range battery adopts traditional gel technology .
The products are designed as standby power for communication, power, military and broadcast and television system with excellent deep cycle performance. The design float life is 18+ at 77oF(25oC)
The Ares(OPzV) range batteries are ensured the quality with NARADA's QA system according to the ISO9001 and ISO14001 standard.

 

Gel Technology Battery Ares(OPzV) Series   8OPzV 800

Gel Technology Battery Ares(OPzV) Series   8OPzV 800

Gel Technology Battery Ares(OPzV) Series   8OPzV 800

 

Type:

  8OPzV 800

Voltage:

  2V

Nominal Capacity:

  800Ah(C10)  800Ah(10 hours rate:)

Length:

  191mm

Width:

  210mm

Height:

  646mm

Height   with termial:

  678mm

Weight:

  65Kg

Gel Technology Battery Ares(OPzV) Series Technical Feature:

  • Traditional gel technology

  • 18+ years design life under floating application   and cycle life is above 1200 at 80% DOD   under temperature 25 oC.

  • Reliable seal performance, no acid spillage, recombination efficiency reach 99.9%

  • Initial capacity above 100%, the remaining capacity above 94% after storage for 3 months (25oC)

  • low float charge voltage. design (2.23V/cell, 25oC), extremely consistent float charge voltage
     Flexible connectors and convenient installation

Gel Technology Battery Ares(OPzV) Series Compliant Standards :

  • IEC60896-21/22

  • Din standard

  • UL

  • Manufactured under system ISO9001(TUV) and ISO14001(DNV) by Narada

Gel Technology Battery Ares(OPzV) Series Battery Installation Compliant with:

  • EN 50272-2 or local equivalents

Gel Technology Battery Ares(OPzV) Series Main Application:

  • Telecommunications

  • Motive power applications

  • Railway and mining markets

  • Uninterruptible power supply (UPS)

  • Solar energy storage application

  • Other applications to provide integrated stored energy system

Gel Technology Battery Ares(OPzV) Series Products Characteristics:

  • Recommended float charge voltage for 2V battery: 2.23Vpc at 25oC(77oF)

  • Self discharge rate :< 2% per month  at 25oC(77oF)

  • Design life: 18+ years at 25oC(77oF)

  • Shelf life: 6 months at 25oC(77oF)

  • Valve regulated system, no water addition needed

FAQ


What is sulfation of batteries?

Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to repair the battery?
Maintain the battery before, first of all to clean up the battery appearance of the dust, remove the terminal above the stain and corrosion.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Q:How does the battery increase the voltage?
With the same battery pack in series; if the required current is relatively small, you can use DC-DC module.
Q:What is the meaning of the battery above 12v65Ah?
12V is said to be the voltage, 65Ah is the current. (A is the unit of current. H is the time unit .1 hours.)
Q:How is the capacity of the battery defined?
General circuit has a battery protection circuit, once the battery voltage is less than 10.8V will automatically cut off the electricity to prevent the battery because of over-discharge and damage. (Nominal value of 12V battery internal six cell grid) with the battery discharge current multiplied by the discharge time to express how much energy the battery can store, is a very image of a measure. The greater the value of the battery, indicating that the battery can store more energy. But does not mean that the battery can use such a large current discharge.
Q:What are the technical parameters of the battery?
Usually the capacity of the power supply is expressed by kV · A or kW. However, as a power supply VRLA battery, the use of security (A · h) that its capacity is more accurate.
Q:How to deal with waste batteries?
The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.
Q:Maintenance-free battery how to detect it?
Check the height of the electrolyte at least once a month. There is no mark line of the battery, the electrolyte added to the plate 10-15mm can be higher; there are two red line of the battery, the electrolyte can not exceed the red line above.
Q:What battery does the van use?
General use of lead-acid batteries. Electrode is mainly made of lead and its oxide, the electrolyte is a sulfuric acid solution of a battery. English: Lead-acid battery Discharge state, the main component of the cathode is lead dioxide, the main component of the negative lead; charge state, the main components of the positive and negative are lead sulfate. Divided into exhausted batteries and maintenance-free lead-acid batteries.
Q:The role of the battery?
Battery is a kind of battery, its role is to be able to save the limited power, in the right place to make 6v4ah emergency light battery. Its working principle is to convert chemical energy into electricity.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range