 Range summary:

The MPG range gel batteries are designed with front terminal structure. The perfect design ensures MPG series battery the high reliability and makes the installation quite simple and safe when placed on a standard relay rack tray or in a closed cabinet. Adopt Flat plates with gel electrolyte.

This new technology leverages on the advantages of the AGM and Ares technology to provide better cycle performance versus the AGM technology and a shorter time discharge performance as compared with the Gel technology.

MPG range gel battery is designed with high energy density and suitable for 19", 23" rack or cabinet, and also offers options of top connection and side of monoblocs connection. MPG range battery can be equipped with central gas collection system according to the requirement of customer.

The MPG batteries are ensured the quality with the ISO9001 standard.

Gel  Battery MPG Series Battery MPG12V150F

Technical feature:

  • Gel technology applied in MPG range batteries.

  • Front-access terminal connections for fast and easy installation and maintenance

  • Suitable for 19", 23" rack or cabinet

  • Excellent special lead-tin-calcium formula alloy for Grids and plates

  • Mircoporous glass mats in low resistance as separator

  • Self-regulating pressure relief valve

  • 12+ years expectant Life under full float service at 25oC(77oF)

Type:

  MPG12V150F

Voltage:

  12V

Nominal Capacity:

  150Ah(C10)  150Ah(10 hours rate:)

Length:

  558mm

Width:

  125mm

Height:

  310mm

Height  with termial:

  310mm

Weight:

  52Kg

Compliant standards :

  • IEC60896-21/22

  • Din standard

  • UL

  • Manufactured under system ISO9001(TUV)

Battery installation compliant with:

  • EN 50272-2 or local equivalents

Main application:

  • Telecommunications

  • Uninterruptible power supply (UPS)

  • Switchgear / utility

  • Other applications to provide integrated stored energy system

Products characteristics:

  • Recommended float charge voltage for 12V  battery:

  • 2.25Vpc at 25oC(77oF)

  • Self discharge rate: < 2% per month at 25oC(77oF)

  • Shelf life: six months at 25oC(77oF)

  • Valve regulated system, no water addition  needed.

FAQ


What is sulfation of batteries?

Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

How can I evaluate the health and charge state of a battery?

Routine battery examinations divulge irregularities in the charging system as well as in the batteries. The principle method is to examine the electrochemistry of the battery through hydrometric electrolyte inspection. As previously discussed, this important examination cannot be accomplished with sealed absorption or gel batteries. Voltage readings alone require experience to interpret. Hydrometric readings will uncover early warnings of overcharging or overdischarging before batteries are damaged. The state-of-charge and reliability of a lead acid battery can best be determined by the specific gravity of the electrolyte measured directly with a common bulb-type hydrometer with a glass float. We do not recommend the ball float type hydrometer. Specific gravity is a unit of measurement for determining the sulfuric acid content of the electrolyte. The recommended fully charged specific gravity of marine batteries is 1.255 to 1.265 taken at 80ĄăC More than .025 spread in readings between fully charged cells indicates that the battery may need an equalization charge. If this condition persists, the cell is failing and the battery should be replaced. Since water has a value of 1.000, electrolyte with a specific gravity of 1.260 means it is 1.260 times heavier than pure water while pure concentrated sulfuric acid has a specific gravity of 1.835.


 

Q:What is a maintenanceable battery?
It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
Q:Battery 200ah / 104 what does that mean?
2V battery capacity (from 200AH-3000AH have) long design, good stability, the price is also expensive; 12V battery capacity is generally the largest 250AH, design life as 2V, price economy, high current discharge better.
Q:How to determine the battery is good or bad?
Observe the battery electrolyte is turbid, turbidity that the battery positive plate softening. Observe the bottom of the battery whether there is sediment, if the plate off the battery capacity has been inadequate. Hand hit the battery two electrode piles If you hear an empty voice that pole pile and plate break. With a thick wire short-circuit positive and negative pile observation of the battery filling holes, such as the discovery of a bubble appears that the interval has been damaged.
Q:What is the difference between a maintenance-free battery and a conventional battery?
As a result of maintenance-free batteries using lead-calcium alloy grille, the amount of water generated when charging less water evaporation, coupled with the shell with a sealed structure, the release of sulfuric acid gas is also very small, so it compared with the traditional battery, With no need to add any liquid, the wiring pile head, wire and body corrosion less anti-overcharge capacity, starting current, power storage time is long, by the car people welcome.
Q:What is the meaning of the battery above 12v65Ah?
Voltage 12V, current 65AH, that is the capacity of 65A. (A is the unit of current. H is the time unit)
Q:How to repair the battery?
Charge the battery at constant voltage. It is the beginning of the time, using 0.1C ~ 0.25C current charge, to 16.2V later, by reducing the current method to maintain the charging voltage, until the charge current drops to 0.03C when the stop charging.
Q:How to deal with waste batteries?
The rest of the various types of waste batteries are generally shipped to a special toxic, hazardous landfill, but this approach not only cost too much but also cause waste, because there are many useful raw materials available.
Q:80ah how much battery storage capacity?
Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
Q:What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q:How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords