1.Structure of Gate Valve Description

A gate valve, also known as a sluice valve, is a valve that opens by lifting a round or rectangular gate/wedge out of the path of the fluid. The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. For extremely thick fluids, a specialty valve often known as a knife valve is used to cut through the liquid. On opening the gate valve, the flow path is enlarged in a highly nonlinear manner with respect to percent of opening. This means that flow rate does not change evenly with stem travel. Also, a partially open gate disk tends to vibrate from the fluid flow. Most of the flow change occurs near shutoff with a relatively high fluid velocity causing disk and seat wear and eventual leakage if used to regulate flow. Typical gate valves are designed to be fully opened or closed.When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low friction loss.

 

2. Main Features of the Gate Valve

• Valve body cavity using non-toxic epoxy resin,both inside and outside flashboard completely is coated with rubber

•  Free of water pollution

• High manufacturing accuracy

• High strength

• Environmental protection and energy saving

• Good visual effect

 

3. Images

Gate Valve, Various Model, Professional Leading Manufacturer

Gate Valve, Various Model, Professional Leading Manufacturer

 

4. Gate valve Specification

 Gate Valve, Various Model, Professional Leading Manufacturer

5.FAQ

1. What's are the characteristics of gate valve?

The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. 

2. What is the work principle of gate valve

 The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. 

3.  What is the structure?

Bonnets provide leakproof closure for the valve body. Gate valves may have a screw-in, union, or bolted bonnet. Screw-in bonnet is the simplest, offering a durable, pressure-tight seal. Union bonnet is suitable for applications requiring frequent inspection and cleaning. It also gives the body added strength. Bolted bonnet is used for larger valves and higher pressure applications.

 

Q:Why? God, can you explain to me in detail why?
Pump outlet, check valve, gate valve.Gate valve plays a regulatory role, is the main pipe. Such a sequence can ensure that the water flow during power failure does not cause damage to the gate valve.
Q:The difference and use of gate valve and stop valve
Generally large and nominal caliber DN50 mostly with gate valve, especially industrial high temperature, high pressure, highly toxic and so on.Stop valve is able to stop and adjust flow, small footprint, small size, generally less than the nominal diameter, DN50 occasions use it. Two can be closed, in the flow of linear requirements are not high, you can adjust the flow. Just because of its structural characteristics of the valve to make its flow resistance, so there is a demand for throttling with a little more than the gate valve. In addition, the cut-off valve, whether it is a formal or reverse installed, in the opening and closing process, there is always a very difficult, and therefore can not do a great deal, or it is not easy to open and close. In addition, the cut-off valve has a one-way sealing effect of good features, so in the prevention of reverse flow of the working fluid, it also has a place to play.Hope to be of some help to you!
Q:Function of gate valve
The valve (including the valve and valve) is a fluid pipeline control device, its basic function is to connect or cut off the pipeline medium circulation, changing the medium circulation, change the direction of the flow medium, medium pressure and flow regulation, to protect the normal operation of pipeline equipment.
Q:Valve flange drawing n- up to what
A bolt hole used to indicate a flangeThe value of N indicates the number of bolt holesUp to the numerical representation of bolt hole size
Q:What do you mean by gate valve type RVHX-0150-10 and Z45X-16Q?
Z45x-16q, Z means gate valve, 4 means flange connection, 5 refers to dark rod gate valve, X means rubber seal, 16 refers to nominal pressure 1.6MpaRVHX means manual gate valve, 150 refers to the caliber of DN150, and 10 indicates nominal pressure of 1.0MPa
Q:What's the difference between a soft seal gate valve and a hard sealed gate valve?
Soft sealing gate valve is rubber seal, F sealed, hard sealing gate valve is the medium of particles.
Q:Why the valve can only be fully open and fully closed valve can adjust the flow?
Gate valve, stop valve are switching type valve, adjust the flow can not talk about, can only do so called throttle.You say "stop valve" or "translation" problem, in English, globe valve and valve word is often the same.
Q:Why can't the pressure measuring point be set at the two ends of the gate valve when measuring the resistance loss of the gate valve?
Because of the unsteady flow of fluid near the inlet and outlet of the valve, the measured data cannot be obtained relatively accurately.
Q:What type of flange does it fit with the gate valve?
This depends on the type of gate valve, valve standards are marked with matching flange standards. Different types of flanges for different gate valves are also different.The flange of General GB gate valve is GB/T9113 series.
Q:Gate valve is gate valve, gate valve specifications, model code is generally what?
Gate valve is not gate valve, gate valve does not have a fixed specific model

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products