Gate Valve Ductile Iron Rising Stem Resilient Seated

Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
200 m.t.
Supply Capability:
10000 m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Item specifice:

Material: Cast Iron Pressure: High Pressure Temperature of Media: Normal Temperature
Power: Manual Media: Water OD(Outer Diameter: inch): 400
Size(inch): DN300 Pressure(LB): 400 Net Weight (kg): 177

Product Description:

1.Structure of Gate Valve Description:
Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. For extremely thick fluids, a specialty valve often known as a knife valve is used to cut through the liquid.This means that flow rate does not change evenly with stem travel. Also, a partially open gate disk tends to vibrate from the fluid flow.

2.Main Features of the Gate Valve:
The sealing surface of valve seat and gate is overlaid (surfaced) with hard alloy, resistant to corrosion and abrasion.
Valve seat, gate and stem are sealed with imported lip-shaped combined seal structure, so they are safe and reliable, and the switching torque of valves is low.
Simple and safe design of valve gate and seat, makes it easy to change without special tools.
Non-rubber seal effectively protects valve chamber from mud, sand and rock, etc.
Stem sealing can be changed under pressure.
Stem is designed to be rising stem and non-rising stem, with a clear sign for valve opening.
Drive mode falls into manual, hydraulic and gear.
Combining type falls into flange, thread and hub.

3.Images of the Gate Valve
 Gate Valve Ductile Iron Rising Stem Resilient SeatedGate Valve Ductile Iron Rising Stem Resilient Seated

4.Specification of the Gate valve
Working medium: water, non-corrosive liquid, saturated vapor (≤ 0.6MPa)
Operating temperature: -20 °C ≤ t ≤ 135 °C
Stem: non-rising stem
Body material:Brass/Gray Cast Iron
(1)Forged Brass Screw Gate Valve, Brass valve, Brass Gate Valve
(2)Forged body, cast iron handle
(3)Can be changed to allum. handle
(4)Cast Iron Wheel Handle, can be changed to allum. handle
(5)Screw Ended
(6)Material: CW614N, CW617N, C37700 as per request.
(7)Thread: BSP, NPT as per request
1. What's are the characteristics of gate valve?
The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel.
2. What is the structure?
Bonnets provide leakproof closure for the valve body. Gate valves may have a screw-in, union, or bolted bonnet. Screw-in bonnet is the simplest, offering a durable, pressure-tight seal. Union bonnet is suitable for applications requiring frequent inspection and cleaning. It also gives the body added strength. Bolted bonnet is used for larger valves and higher pressure applications.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What kind of valve is it? How do you see the status of the switch?
This is called gate valve. The core is opened and the core is screwed down. Turn left and right.
Q:What's the advantage of using three way valves?
A valve can be used to turn on and off and change the flow direction of the medium.
Q:What does 3/4''mean in the name of the valve?
Valve diameter, that is, we often say 6 points valve, used in English units, with metric units should be DN20.2 points DN84 points DN156 points DN20 (3/4'')1 inches DN251.2 'DN321.5 'DN402 'DN502.5 'DN653 'DN804 'DN1005 'DN1256 'DN1508 'DN20010 'DN25012 'DN300Nominal diameter (nominal, diameter), also known as the average diameter (mean, outside, diameter).The tube is thin from the metal tube, and the outer diameter of the tube is almost the same as the inner diameter of the tube, so the average value of the outer diameter of the tube and the inner diameter of the pipe is called the diameter.Because the units have metric (mm) and British (inch) distinction, there are the following methods of address.1., based on the metric system (mm), called DN (metric unit)2., on the basis of the British system (inch), called NB (inch unit)DN (nominal, diameter)NB (nominal, bore)OD (outside, diameter)
Q:Valve difference
That depends on where it is used! No one knows how many kinds of valves. If you have water, you can use gas, food, and so on.
Q:What's the valve as a unit?
Business now there are many valve manufacturers, with the rapid expansion of SMEs, SMEs are more ~!
Q:How do you calculate the valve wall thickness, pressure, and other valve design calculations in a spreadsheet?
Which standard does the wall thickness refer to? ASME B16.34?Design and calculation depends on what standard you chooseOr have you found the standard yourself and read it yourself?You choose what standards, design parameters reference, interpolation or fitting, how to fit, are their own sayI wrote a excel series of valve calculations, it does not take long to writeFor long-term useIn order to improve efficiencyOr write your own database program is better
Q:Is there any problem with connecting the geothermal valves with other geothermal pipes?
Can be universal,Material is the same, the fuse will not cause shrinkage when you can use
Q:Valve pressure test
The standard is different, the test is not the same, what kind of valve you, a domestic valve only do stress testing, in fact, the pressure can generally be guaranteed, many are bad at high temperature or life testing above
Q:Why is copper used in cryogenic valves?
Contact with water does not corrode easily。he influence of temperature on copper is smaller than that of steel. Especially in the valve stem, there is also the important gear part, copper!
Q:What is the normal temperature on the valve?
3. classification by operating temperature(1): ultra-low temperature valve for medium temperature of t< DEG C; 101 valve.(2): used for medium temperature valve operating temperature 101 C = t = 29 C valve.(3) at room temperature for medium temperature valve: the valve 29 425 degrees celsius.If it helps, see it

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range