Galvanized steel Galfan wire 5% al-zn alloy coated wire
- Ref Price:
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 m.t.
- Supply Capability:
- 10000 m.t./month
- OKorder Service Pledge
- Quality Product
- Order Online Tracking
- Timely Delivery
- OKorder Financial Service
- Credit Rating
- Credit Services
- Credit Purchasing
Quick Details
Place of Origin: Tianjin, China (Mainland)
Model Number: 6#-22#
Surface Treatment: Galvanized
Galvanized Technique: Electro Galvanized
Type: Loop Tie Wire
Function: Baling Wire
Wire Gauge: 0.7-6mm
Business Type: Business Type
Raw material: Low carbon steel, Structural Carbon Steel,Q195
Elongation: 10% -12%
Zinc Coating: 10-270g/sqm
Standard: EN,BS,ASTM,GB
Packaging & Delivery
Packaging Details: | 25kg or 50kg for each coil,According to customer's requirements |
---|---|
Delivery Detail: | 15 |
Product Description
Business Type | Manufacturer | |||
Wire Type | Zinc coated wire/Galvanized wire | |||
Usage & Performance | Baling wire,Binding wire.weaving wire mesh, construction, handicrafts, express way fencing mesh, packaging of products, equipment, medical equipment, brushes, cables, | |||
Wire Gauge | BWG 4-22 Galvanized Wire Diameter: 0.7-6mm | |||
Zinc-plated | Hot dipped Galvanized or Electro Galvanized | |||
Raw material | Low carbon steel, Structural Carbon Steel,Q195 | |||
Tensile strength | >350 MPa | |||
Elongation | 10% -12% | |||
Zinc Coating: | 10-270g/sqm Electro Galv. Wire-Zinc coating: 10g-25g/m2, Hot Dipped Galv. Wire-Zinc coating: 40g-70g/m2/200g-270g/m2 | |||
Standard | EN,BS,ASTM,GB | |||
Certification | ISO9001:2000, CE, | |||
Packing | Standard Coil Packing Unit | Weight | 25kg or 50kg for each coil | |
Inner Dia. (φ/mm) | 200/400 | |||
Inner Wrappage | Plastic film | |||
Outside Wrappage | Woven bag or Hessian cloth | |||
Export Bulk Packing | Export Packing | 500kg or 1,000kg for each coil | ||
Customized Packing | 5kg to 500kg for each coil | |||
Bulk Packing | 500kg/ Bulk coil | |||
Inner and Outside Dia. (φ/mm) | According to customer's requirements | |||
Wrappage | According to customer's requirements | |||
Loading Quantity | 20’GP | 20-25 Tonne/Tonnes | ||
40’GP | 25-27 Tonne/Tonnes | |||
40’HQ | 25-27 Tonne/Tonnes | |||
MOQ | 1 kg for trial order | |||
Supply Ability | 10,000 Tonne/Tonnes per Year | |||
Payment Terms | T/T or L/C at sight | |||
Delivery Time | Within 15 days after receiving deposit or original L/C at sight | |||
Remark | Customized order and specific requirements is available. |
- Q:Just got a 540 wat sound system but the speaker wires are only 5 feet, so I want to add about another 10 or 15 feet.
- The tape won't make a good sufficient - stable connection. A unfastened connection gets very heat. #4 can carry quite some amperage. acquire some copper - chop up bolt - kearney connectors, which would be put in with 2 wrenches, it could have a divider interior the middle so each cord would be clamped in my view, (might desire to be tight) and wrap a minimum of three wraps of a good grade of electric powered tape - a brilliant ironmongery shop can help you.
- Q:I have two kicker cvr 12s looking to wire them to an acoustic 601se amp can someone please tell me how to wire them like by matching the dots up and stuff.
- Wire okorder / You want the series coils /woofers in parallel option.
- Q:ok so i wired the subs to the amp now, the positive (Red) goes to the battery, the ground (Black) is currently grounded to the metal under my drivers seat. My question is does it matter the color wire is that goes to the stereo? Can i use a red or black? Does it really matter? If not, where exactly would i hook it up behind my aftermarket sony headunit?
- I was once considering of tapping into the 12v constant on the HU like I do in 95% of the installs i've ever achieved. Are you talking about the far flung wire connection? If so, you commonly mean the accessory wire, now not the steady wire; and to be able to be a hindrance within the Trailblazer in view that there is no accent energy wire in the radio harness. I might recommend using a line output converter that has a developed-in trigger circuit, so it will flip the amp on when it detects an audio signal coming from the head unit. There's no excellent position to connect a faraway wire in a Trailblazer with a manufacturing facility head unit. You could hook up with the accessory vigour output on the key change harness (a thick brown wire) however then the amplifier will flip off with the important thing, alternatively of staying on unless the door is opened like the radio does. The Motorola box is for the Onstar procedure, and there isn't a motive to do something with it at all. Sixteen feet of vigor wire maybe sufficient or would now not; depends upon where you position the amp. The battery and firewall access is on the motive force's part, so in case you maintain the amp on the driver's aspect of the vehicle, you'll in most cases have ample wire.
- Q:my speaker makes a fuzzy or static noise while the scene has high or low sound. I cut my wire in half because I bought a subwoofer and we didn't get the wires with it. So I cut it. After all I didn't need the wire for the subwoofer. Could my speakers make such noises because of cutting a wire?
- Shortening your speaker wire will not cause this problem. In fact, shortening your speaker wires should give you less static since there is less resistance. Most than likely, it's not your speakers causing the static sound, but your amplifier or receiver. You may be looking for a new one soon.
- Q:How can I stop my cat from chewing wires? He does it all the time, and the wire he ends up being important.
- Get yourself a little spray bottle/squirt gun and spray him when he bites on the wires. hopefully that will condition him not to do that....I have 2 cats that both chew on wires and that worked on the first one, but not so much the 2nd yet.
- Q:my dogs have chewed my central air contactor wire.my ac will not cut on. does anyone knows how to replace them and where to buy replacement wires locally( i live in Dallas TX.) i would like to do it myself instead of spending a lot of money.
- You shouldn't need to replace the wires, only splice them back together, color to like color. If you decide to replace them, they are 18 gauge. Depending on the unit that you have, there may be 2, 3, 5, 7, or 9 wires. Install the wire in 3/8 flex to prevent a repeat. Lowes and Home Depot will sell you the wire by the lenght you need. Ask for jacketed wire.
- Q:I notice my 10/100 Ethernet wire uses 4 wires (2 twisted pairs). I'm curious what each wire is used for. I understand one pair is for Tx (transmit) and the other for Rx (receive) but why does it need 2 wires for each? I assume bits of data cross on one, but what of the other?
- This is an ethernet only cable. A full patch lead has 8 cables. Yours is STILL an ethernet cable. The additional blue pair would be telephone and the brown pair was unused, but is commonly used for power over ethernet now. ANY data connection requires 2 cables to balance the signal. In effect one is pushing voltage while the other is pulling and vice versa. One is signal, in effect the other is a ground, bur the idea is that by using twisted pair cables the inductive voltage created in one polarity on one is cancelled by the inductive voltage returning on the other in opposite polarity. The same rule applies to external interference from other equipment as these are also cancelled. If it used one cable and a common ground you can never guarantee this immunity to interference.
- Q:When was the hot-wire anemometer invented? and who was it?
- Who Invented Anemometer
- Q:I know what spark plugs are and where they are... but not sure what is meant by wires...For example checking/replacing spark plugs and wires to see if a problem is fixed..Are wires what hookup to the spark plugs from the (distributor?)
- complicated issue. lookup onto bing and yahoo. it could help!
- Q:One hundred meters of a certain type of wire has a resistance of 7.2 Ω. What is the resistance of 2.5 m of this wire?I figured it would just be a proportion so (7.2 * 2.5) / 100 = 0.18 Ω. Is this the correct approach?
- yes, it's a proportion. (2.5/100)7.2 = 0.18 ohm A little more analytical approach is dimensional analysis. I sometimes get proportions backwards, but dimensional analysis prevents that. 7.2Ω/100 m = 0.072Ω/m 0.072Ω/m x 2.5m = 0.18Ω .
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Similar products
New products
Hot products
You Might Also Like