Product Description:

Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:In the case of the inverter, why can not the normal operation after removing the gearbox? The motor is 4 pole.
If there is a load, it may be less than the torque. So it can not run.
Q:Do you need to rectify before switching?
Need to rectify. The inverter is actually an inverter, which first turns the alternating current into direct current, then switches the DC power with the electronic components, changes to alternating current, and the general-purpose inverter is equipped with a thyristor and an adjustable frequency The frequency is adjustable in a certain range, and it is used to control the number of revolutions of the motor, so that the number of revolutions can be adjusted within a certain range.The frequency converter is widely used in the speed regulation of AC motor. Technology development direction, with the development of power electronics technology, AC frequency conversion technology from theory to practice gradually mature. Inverter not only smooth speed, large range, high efficiency, start current is small, smooth operation, and energy saving effect is obvious. Therefore, the exchange frequency control has gradually replaced the traditional traditional slip speed, variable speed control, DC speed control system, more and more widely used in metallurgy, textile, printing and dyeing, smoke machine production lines and buildings, Water supply and other fields. Generally divided into rectifier circuit, flat wave circuit, control circuit, inverter circuit, and so on several major parts.
Q:Will the motor suddenly stop when the inverter is suddenly powered down?
but there are exceptions, such as head pump, water hammer effect after power failure will make the motor Reversal
Q:How to learn the inverter debugging and design parameters
Personally think it is relatively simple, and now the inverter has been more intelligent, and some simple applications, and even do not need to set the parameters.
Q:Laptop adapter heat
In fact, as long as the power adapter temperature is within the design range, that is, the temperature in the normal range, the general is not dangerous! So why is the power supply hot? What kind of temperature range is the normal range? Switching power supply conversion efficiency can only reach 75% -85% or so. The answer is here. Switching power supply conversion efficiency is high enough, it is still difficult to find a better way to convert. Switching power supply in the voltage conversion, a part of the energy loss, in addition to a small part of the loss in the form of waves, the majority of the way out of the heat. Switching power supply power is missing, the loss of energy is also missing, the power of the heat is also large. This is why the desktop power supply to add a fan for cooling reasons. We may wish to count, a 100W switching power supply, in the use of how much energy loss in the above!
Q:Will the asynchronous motor pole change the number of speed control can also be combined with the frequency converter
but the use of the inverter is based on changes in the load by changing the frequency of power into the motor at any time speed control, you can achieve a smooth and accurate stepless speed control is Now widely used in a speed control method, especially for the load often change or often in the light load operation of the motor.
Q:Motor nameplate on the standard 2P, I set the number of motor pole in the inverter, is set 2 or 4 pole?
n the motor pole, an Antarctic (S pole), an Arctic (N pole), calculate a pair of poles, the number of pole pairs is how many such "pairs" (S pole + N pole). 2 pole motor --- pole pairs 1 = P = 1,4 pole motor --- pole pairs 2 = P = 2, and so on.
Q:380V motor addition to the inverter, but also how to change its speed?
Use the star connection to reduce the speed by changing the torque
Q:55 瓩 4 pole motor with a frequency of one hour can save much electricity
it is used in the fan pump load can save about 14-22 kWh, used in the general category, on Multiply your number by 55.
Q:Yaskawa inverter reported base blockade what is the reason?
Yasukawa compared garbage on the signal board on the small line of poor oxidation, and get like, this is a weak signal, and safety relays connected, do not use high-grade security circuit with a small line short, Yasukawa A 1000 factory is short for a long time after the oxidation of the base blockade

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range