Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to choose the right inverter?
Inverter selection science or not for the normal operation of the frequency conversion system is essential. Many beginners on the general inverter selection method is not enough understanding, or even know the method, not sure the choice of the inverter model is positive solution, the following for everyone to solve the mystery. Inverter selection first look at the AC motor. Because the frequency conversion system generally first determine the motor, then select the inverter. In principle, it is necessary to determine the inverter model based on the actual current at which the AC motor is operating for a long time, and not on the motor nameplate. Inverter selection next depends on the load type. Frequency conversion system driven load equipment can be divided into three types: constant torque load, constant power load, fan, pump load, different load type select the inverter model is different.
Q:What is the laptop adapter
2, the basic composition: input line + charger main body + output line + connector such as Acharger single-band notebook charger composition, which constitute the basic elements of the notebook charger, as inside the internal parts is very complicated.
Q:Do you need to rectify before switching?
There are two ways to convert frequency, that is, cross and cross the intersection, the latter need a direct current, need no rectification, depending on your DC situation.
Q:What is the common COM point of the PLC and the inverter? Is it positive?
Generally refers to the common, and most of the negative
Q:My laptop can not use the power adapter, and can only use the battery, how is it ah,
1, laptop power adapter can not be used, first check the power outlet, plug, cable has no virtual state, if you can tell the normal equipment damage. Should be repaired. 2, the laptop battery must be charged through the power adapter or directly for the computer power, the power adapter is not missing, if you have experience can turn on the power adapter to see if the fuse is broken, try to update the fuse can be restored. If the integrated circuit is damaged, only updated.
Q:What is the working principle of high voltage electrodes and frequency converters?
The general high and low methods are used in low-power high-voltage motor to do with energy-saving energy. Low-high-mode high-voltage inverter is controlled by a low-voltage inverter, the voltage directly to the motor with a step-up transformer voltage. Low-high mode is also used in low-power high-voltage motor to do with energy-saving energy.
Q:How does the variable frequency motor output torque at very low frequencies?
50hz the following frequency, u constant, current and frequency is proportional to the frequency down the output current is also down, and torque and current is proportional to the natural torque is small
Q:Does the inverter set the number of poles to match the number of poles of the motor?
The inverter will adjust the voltage and frequency of the output power by the breaking of the internal IGBT, according to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition, the inverter has a lot of protection , Such as overcurrent, overvoltage, overload protection and so on. With the continuous improvement of industrial automation, the inverter has also been a very wide range of applications.
Q:Laptop power adapter (no power supply, but indicator light)
There may be reasons for the power adapter, there may be a computer can not identify the power supply is battery-powered or AC power. These are just speculated by your phenomenon, if you are better in the warranty period to the customer service test, so the best
Q:I have a 11KW-4 pole inverter, now with the 4KW-4 pole motor, what impact?
11KW the following can be brought, the inverter rectifier module may be broken,

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range