Product Description:


SVF-M mini vector variable frequency drive for water pump

 

Technical Specification

Control Characteristics

Control Mode

SPWM (Sinusoidal Pulse Width Modulation) control (V/F sensorless vector control)

Freq. Setting Resolution

0.1Hz

Output Freq. Resolution

0.1Hz

Torque Characteristics

Including the auto-torque, auto-slip compensation, starting torque can be 150% at 5.0Hz

Overload Endurance

150% of rated current for 1 minute

Skip Frequency

Three zones, settings range 0.1~400Hz

Acc/Dec Time

0.1~600s (Independent settings)

V/F Curve

Arbitrary V/F curve setting

Stall Prevention Threshold Frequency Setting

20~200%, Setting of Rated Current

DC Injection Braking

Operation frequency 0.01~60Hz, output 0~100% rated current, start time 0~5s, stop time 0~25s

Braking Torque

Approx. 20% (up to 125% possible with option brake resistor or brake unit externally mounted)

Operating Characteristics

Frequency Setting



External Signal

Potentiometer 5kΩ/0.5W 0~+10VDC, 4~20mA, interface RS485; Multi-function Inputs (7 steps, Jog, Up/Down)

Operation Setting Signal

Keypad

Set by RUN, STOP

External Signal

S0~S5 can be combined to offer various modes of operation, RS485 serial interface (MODBUS)

Multi-function input signal

Multi-step selection 0 to 7, Acc/Dec inhibit, two Acc/Dec switches, External Counter, Jog, PLC operation, External Base Block, auxiliary motor protection, auxiliary motor control is invalid, drive reset, UP/DOWN key settings

Multi-function output signal

AC drive operating, frequency attained, zero speed, PLC operation, counter attained, over torque, base block, operation mode, fault indication, drive is ready, overheat alarm, emergency stop

Analog output signal

Indicate output frequency, current, voltage, frequency command, speed, power factor output signal

Alarm Output Contact

Drive is fault, the contact will be ON

(One form C contact or 3 open collector outputs)

Operation Functions

AVR, over-voltage, over-current stall prevention, 3 fault records, reverse inhibition, momentary power loss restart, DC injection braking, auto torque compensation, slip compensation, S-curve, auto tuning, adjustable carrier frequency, frequency limits, parameters reset, vector control, PID feedback control, external counter, PLC, MODBUS communication, abnormal reset, abnormal restart, digital frequency output, sleep/revival function, 1st/2nd frequency source selections

Protection Functions

Over voltage, over current, under voltage, external fault, overload, contact protection, overheating, electronic thermal, ground fault

Display Keypads

6-key, 4-digit, 7-segment LED, 4 status LED, master frequency, output frequency, output current, custom units, parameter values for setup, review and faults, RUN, STOP, RESET, FWD/REV

Built-in brake chopper

Built-in for all models

Environment Condition

Protection threshold

IP20

Pollution Degree

2

Installation location

Altitude 1000m or lower, keep from corrosive gasses, liquid and dust

Ambient temperature

-10°C~50°C non-condensing and not frozen (-10°C~40°C for above 5.5KW)

Storage/Transportation temperature

-20°C~60°C

Ambient humidity

Below 90%RH (non-condensing)

Vibration

9.80665m2(1G) less than 20Hz; 5.88m/s2(0.6G) at 20 to 50Hz

Approvals


 

Technical Parameter

 

  

VFD Capacity

Input Voltage (V)

Power Capacity (KVA)

Input Current (A)

Output Current (A)

Adapter Motor(KW)

3.7S/T2B

3 Phase 230V

5.9

19.6

18

3.7

 

 Model Size

 

VFD Model

W1

H1

W

D

H

Installation Aperture  

Weight (Kg)

SVF-MN3.7S/T2B

110.0

205

125

166

220


3.2

 

 


Accessories

 

 

Company Introduction                         

 

 

 

Shandong Chinsc Electric Technology Co., Ltd. is a manufacturer of professional inverters integrating research and development, production and sales. With advanced technologies, excellent quality, scientific management and perfect services, we are building a first-class inverter manufacturer gradually.

 

Currently, our company has introduced CHINSC inverter models such as SVF3000 series, SVF-M series, SVF-EV series, SVF-G7 Series 0.4 ~ 630KW, to the markets. With excellent product quality, excellent technology development capabilities and comprehensive after-sales services, CHINSC inverters have won praise among agents and customers across the country.


 




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Inverter signal line analog 4-20mA connection positive and negative can be reversed?
Theoretically reverse seems to be possible, but the operation will be normal, you can do experiments to try what is the result. Various manufacturers of the inverter may be the treatment of this problem will be different.
Q:Speed regulation method of three - phase asynchronous motor
Change the number of pole pairs can be adjusted, in the way around the stator coil through the tap method can achieve two-speed. With the popularity of the inverter, three-phase asynchronous motor speed mostly with the inverter.
Q:Notebook plug in the power adapter lights, but can not open the machine
This is a contradictory problem: First, the power adapter lights because the power is good, but does not mean that the computer is good; Second, can not open the machine with the power adapter is lit, it is your computer reasons. Recommendation: Check the computer hardware. Asked: But the battery can be used to start ah answer: Remove the battery plug in the adapter or put the battery installed plug in the adapter, if you can not open the machine, then it is a hardware conflict. The solution to the hardware conflict is that you try another adapter. Asked: the battery removed to die, but as long as there is a battery can answer: it shows that your adapter is bad. Asked: the more magical is plug in the adapter and the battery, the battery will not consume Answer: get you electronic city so that they give you a test. You can say to buy an adapter, and then try, you can use the words to buy, can not use the words and then think of other methods.
Q:How to lift Yaskawa inverter base blockade?
Note: the base blockade is to deal with ul or ce such a special application of security agencies, meaning that when the parking limit action after the base blockade even if the program can not malfunction, relative to the emergency stop loop more harsh, they will directly cut off the power power supply. In fact, it is a white protection function, if we are not difficult to find the analysis, when over-voltage or undercurrent, the panel will show BB alarm, BB is the base block, is the base blockade.
Q:Fuji inverter motor set the number of poles will not have any effect?
The number of motor poles set incorrectly, self-learning when the motor parameters are not correct, not the correct parameters of the motor. Inverter control speed is not accurate, and the motor will heat, can not work properly.
Q:Motor a speed, the inverter will burn what is going on, the inverter is a large yuan
Note that the quality of the inverter is not ye, and now this situation is already very rare, it is recommended to replace the inverter brand, you can use Bosch Rexroth, the British Witten, Huichuan, Senlan, Haili Pu, Ou Rui, etc. Branded.
Q:Lenovo g450 laptop power adapter specifications is what?
Lenovo g450 laptop power adapter specifications is what? Wrqwgp520 | viewed 4426 times Recommended at 2016-05-26 08:52:41 Best answer Lenovo Lenovo 19V4.74A G450 G470 Laptop AC Adapter: 【Power supply technical parameters】 1. Input voltage: AC100-240V.50-60Hz.1.5A 2. Output voltage: 19V 3. Output current: 4.74A 4. Work efficiency:> 85% 5. Output power: 90W 6: Input interface: Plum triangular interface 7: Output interface: 5.5 * 2.5
Q:ASUS and dell notebook power adapter can be universal?
I can not remember to insert into the ah. The Looks like DELL that interface is very special
Q:11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
First, the inverter is no problem, I used so much to meet your needs       But to see if your motor can run at high speed, or whether the load is small, the power to have a general amount of redundancy. 6-pole motor synchronous speed of 1000, to meet your use to be transferred between 2000 or 1900, that is to say the frequency converter output frequency to be transferred to 90 to 100HZ.       Constant torque load is no problem, but the fan torque load to be a small job.
Q:What is the principle and implementation of the inverter?
How the inverter works: 1. DC can be converted into alternating current through the oscillation circuit 2. The resulting AC power is then boosted by the coil (in this case, the alternating current of the square wave) 3. Rectify the resulting alternating current to obtain a sine wave

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range