• Frequency Drive for 3 Phase  0.4kw AC Variable System 1
  • Frequency Drive for 3 Phase  0.4kw AC Variable System 2
Frequency Drive for 3 Phase  0.4kw AC Variable

Frequency Drive for 3 Phase 0.4kw AC Variable

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 ac variable frequency drive for 3 phase water pump and blower with best quality and price

 

Introduction of SVF-G7 Series High-performance Vector General-purpose Frequency Inverter

 

 

1. Voltage class: 380V

 

2. Range of power: 0.4KW~450KW

 

3. Stable and reliable Control Mode

 

(1) VF control: Multiple curve could been chosen, Linear V/F curve, 2.0 times power drop torque V/F curve, custom V/F percentage(can realize manual energy saving control), multipoint VF curve. This apply to the situation that one frequency inverter drives multiple motors, such as fan, water pump, engraving machine, injection molding machine etc.

 

(2) Open-loop vector control: Steady speed with high precision, wide range of speed governing, as the speed ratio is 1:200 and 180% rated torque could be output in 0.5Hz. Good dynamic performance.

 

Open-loop vector is suitable for high-Performance universal occasions such as machine tools, centrifuges, cranes and handling equipment, rolling mill and other loads.

 

(3) Torque control: Fast torque response,<20ms, precision torque: <5%, applied to winding, drawing and other occasions.

 

 

Technical Parameter

 

VFD Capacity

Input Voltage (V)

Power Capacity (KVA)

Input Current (A)

Output Current (A)

Adapter Motor(KW)

0.4T4B

3 Phase 380V Range:-15%~20%

1.0

2.4

3

0.4

0.75T4B

1.5

3.4

4

0.75

1.5T4B

3.0

5.0

5

1.5

2.2T4B

4.0

5.8

6

2.2

 

 

Model Size

 

VFD Model

W1

H1

W

D

H

Installation Aperture  

Weight (Kg)

SVF-G7-G0.4T4B

96

190

105

154

200

Φ4

2.2

SVF-G7-G0.75T4B

SVF-G7-G1.5T4B

SVF-G7-G2.2T4B

 

 

 

Trade terms

 

a. Delivery term

We will delivery for you after you done the full payment within 3 to 15 working days.

b. Payment

For small order by air or by express, it is 100% T/T in advance.

For large order by ocean, 30% deposit of the order value should be paid, 70% of the balance payment should be done before delivery.

c. Packing                            

Unless otherwise stated in the offer, the prices include packing in accordance with CHINSC’S customary standard of packing.

 

Frequency Drive for 3 Phase  0.4kw AC Variable

Frequency Drive for 3 Phase  0.4kw AC Variable

Frequency Drive for 3 Phase  0.4kw AC Variable

 

Q:The laptop power adapter is burned
If the power adapter is burned, you should check the laptop's power outlet, if the socket short circuit will lead to the power adapter burned. Maintenance method is not a power adapter and only use the battery boot try, can not boot, then the laptop itself is a problem, to send maintenance department maintenance; if you can boot, you can confirm that the power outlet is short, can be opened Laptop case, swap a new power outlet to solve the problem.
Q:Laptop computer about electricity no electricity, is the power adapter problem?
To judge this is very simple: 1. The computer is in the battery state to see if it works properly. If it does not work, the battery has a problem 2. Remove the battery from the computer with a power adapter to see if it is working properly. If not, there is a problem with the power adapter 3. If the two states can work that is the computer charge management part of the poor contact and other issues.
Q:What is the working principle of high voltage electrodes and frequency converters?
The general high and low methods are used in low-power high-voltage motor to do with energy-saving energy. Low-high-mode high-voltage inverter is controlled by a low-voltage inverter, the voltage directly to the motor with a step-up transformer voltage. Low-high mode is also used in low-power high-voltage motor to do with energy-saving energy.
Q:A 4-pole AC motor into a 2-pole AC motor, the motor is controlled by the inverter, to make the maximum speed of the 2-pole motor and the original 4-pole
First reduce the frequency of about one-third of the test, not the case, then appropriate adjustments!
Q:Please recommend a high performance laptop power adapter?
See what model you notebook ah, according to your power adapter voltage, rated current to match.
Q:Will the 75KW4 pole motor can be used to increase the speed of the inverter?
can! The output frequency of the inverter is higher than 50HZ, the speed of the motor is higher than the rated speed. In a certain range, the higher the frequency of the inverter, the faster the motor speed.
Q:Why G120 inverter to be equipped with 4-pole motor?
On the upstairs that the motor parameters to be set on the possible, such as voltage, current, power, power factor, rated efficiency, rated frequency, rated speed, motor overload factor
Q:How to choose the inverter
I was doing the inverter, you choose the words, as long as 75KW can be selected, huh, huh, because the 1440 speed is fixed, the connection can be set in the inverter itself,
Q:Fuji inverter motor set the number of poles will not have any effect?
The number of motor poles set incorrectly, self-learning when the motor parameters are not correct, not the correct parameters of the motor. Inverter control speed is not accurate, and the motor will heat, can not work properly.
Q:Three sets of batteries (540V) DC power supply U / f inverter.
It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products