Product Description

 

 

Flexible Cables

 

1.Flexible Cables in different technical specifications are available with us.

 

2.These cables have a contact construction, they are rugged, but flexible for industrial use and have high temperature insulation.

 

3.Our range of Multicore Flexible Cables can be availed in different types of insulation like Standard .

 

4.Heat resistant PVC up to105° C and Standard PVC Of FRLS, which finds varied application in the electrical industry.

 

5.Available in standard width, these multicore flexible cables are offered at competitive prices.

 

Features

 

1. Service Conditions for Flexible cables

This product is suitable for A.C voltage 450/750V or below domestic appliances,power-operated tlls and various portable electric equipments .

2. Performance Characteristics for Flexible cables

1) YZ model rated voltage U0/U is 300/500 V, YC model is 450/750 V .

2) Long time allow working temperature of wire core is not more than 60 .

3) W model cable has the property of durability , so it is suitable for outdoor work touching oil pollution .

4) ZR-model cable has the property of fire-resistance.

 

3. Model Name and Usage for Flexible cables

Model

Name

Main Usage

YQ YQW

Light Model Rubber Sheath Flexible Cable

Used for light portable electric equipment and tools

YZ YZW

Middle Model Rubber Sheath Flexible Cable

Used for various portable electric equipment and tools

YC YCW

Heavy Model Rubber Sheath Flexible Cable

Used for various portable electric equipment which can bear larger mechnical force effect .

 

Other special characteristics: design and manufacture according to customers' request

 

The flexible cable is made from copper conductor, rubber insulation and rubber sheath.

 

1.The rubber sheathed flexible cable with rated voltage up to 450/750v is in accordance with the standard GB5013-1997.

2.Rubber insulated flexible wire and cable with rated voltage up to 450/750v is in accordance with the standard JB8735-1998.

 

Application

1.The long time permissible working temperature of conductor is 60 degree.

2.The product is applied to the drive devices, household electric instruments,

3. electrical equipments and electromotive tools at AC rated voltage up to and including 450/750v.

 

 

Model

Name

Core No.

Section area(mm)

Rated voltage(V)

227IEC01

(BV)

General-purpose, single core, hard conductor cable without sheath

1

1.5-400

450/750

227IEC02

(RV)

General-purpose, single core, soft conductor cable without sheath

1

1.5-240

450/750

227IEC05

(BV)

Inner wiring purpose, single core, solid conductor cable without sheath(conductor temperature:70°C)

1

0.5-1.0

300/500

227IEC06

(RV)

Inner wiring purpose, single core, soft conductor cable without sheath(conductor temperature:70°C)

1

0.5-1.0

300/500

227IEC07

(BV-90)

Inner wiring purpose, single core, solid conductor cable without sheath(conductor temperature:90°C)

1

0.5-2.5

300/500

227IEC08

(RV-90)

Inner wiring purpose, single core, soft conductor cable without sheath(conductor temperature:90°C)

1

0.5-2.5

300/500

227IEC10

(BVV)

Light PVC sheathed cable

2-5

1.5-3.5

300/500

227IEC52

(RVV)

Light PVC sheathed soft wire

2, 3

0.5, 0.75

300/500

227IEC53

(RVV)

PVC sheathed soft wire

2-5

0.5-0.25

300/500

BV

PVC insulated CU-core cable

1

0.75, 1.0

300/500

BVR

PVC insulated CU-core soft cable

1

2.5-7.0

450/750

BVV

PVC insulated and sheathed CU-core circular cable

1

0.75-10

300/500

BVVB

PVC insulated and sheathed CU-core flat cable

2, 3

0.75-10

300/500

RVVP

PVC insulated and sheathed, screened CU-core soft cable

1-24

0.3-2.5

300/300

 

PICTURE

 Flexible xlpe/pvc insulated UL1015 power cable AWG 1/0 2/0 3/0 electric copper wire cable

Q:I am trying to run the power cable leading to the amplifier in my car but can not seem to find a hole or firewall to pass the wire through. My car is a 91 Toyota Tercel. Please and Thank you
The Tercel will have a couple of un-used holes that are covered with black solid rubber grommets. You can poke a hole through one with a pen or screw driver and just push the wire through. You should find these holes one the left and right symmetrically, and they will be near half way down, but closer to the top than bottom. If you can't see them, maybe you can feel for them.
Q:some one told me that cisco get this router without AC power it get the power from the network cable?
You need to make sure your Switch supports POE (power over Ethernet).
Q:I need a longer power cable for my xbox 360 dvd drive, can anyone tell me where I can find out on OKorder?Or what its called? I type in dvd drive power cables on OKorder, but only the short stock ones show up I need one with about 10 inches or so.Thanks!Can these be found in radioshack?
They will ban you, but only if you try and go online with the sata disconnected, or disconnect it when you are online. Provided you haven't tampered with the drive and put it back properly BEFORE you go back online it should be fine. At least, it was fine for us. Disconnect the Ethernet cable while you carry this out to be on the safe side.
Q:I am getting a new 160 amp high output alternator for my 2005 Mazda 3 2.3L. I am running a 1000w amp with two subs. I have the stock alternator in it right now. There are two power cable kits available for me to get. One that has 4 gauge wire with a 100 amp fuse and the other, 1 gauge with 150 amp fuse. Which kit should I get? Can I just add 4 gauge wire along with my stock wire instead of the 1 gauge kit? What are the fuses for and which one would work better? I know nothing about this. Thanks.
I would go with the 1 ga wire. The fuse keeps the wire from setting your car on fire. The size of the alternator does not matter. The battery should supply 700 amps or so.
Q:Since the ps3 uses a universal power cable can any of those cables workthe original cable says 10A and 125v and the other non original says the same it fits however is it safe???
If you are talking about the HDMI cable that goes from your HD TV to the ps3 - then you have to find out the resolution that your tv supports and then find a HDMI cable that matches that resolution you can get these cables at major electronics stores It is best to have a HD TV with the HD cable (improves graphics)
Q:My ac jack is screwed up and I can't plug in the ac adapter. I have heard that there is a power cable that will plug into one of the other ports on the side of the computer to, but I don't know where to find one or what they are called. Also, I have heard there are a million problems with the R3000 - and some can be fixed by taking it apart. I do NOT want to do this. I just need an alternative power cable. The laptop works perfect - if it had power. Thanks in advance. :)
Well, you could try the compag website for costumer support, they will help out.
Q:Hi,I recently bought a daewoo l700c monitor second hand.Its cheap because It didn't come with a power supply/power cable.I know that It requires one of those one point plugs..like the ones that go into some laptops.Help please?
notice the info to the left of the port this is importent take this info with you when you look for one of these
Q:Explain why a bird sitting on a 400 kV power transmission cable is not electrocuted?
Electrocution is created by the passage of electric current through living organs. A bird sitting on a 400 KV power line is charged at 400 KV but it takes a *potential difference* to cause current to flow. As the bird is only touching one side of the 400 KV line there is no potential difference across the bird therefore no current flows thru it. Hence bird isn't electrocuted.
Q:hey guys, i recently bought a new desktop computer however when i unpacked it and put it all together i discovered that i had not received a power cable for the tower. i discovered an old one in the mess that is my bottom drawer and was wandering does it matter what power cable is used for the tower? or are there different power cables for different PSU's?
As long as it fits, it should work.
Q:I need a replacement power cable for an ASUS VH222H monitor ASAP.Would this work?
the end that goes into your computer... compare that to what you see in the package.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords