flexible insulation air duct expandable flexible insulation air duct High-tensile steel wires
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 m.t.
- Supply Capability:
- 1 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Place of Origin: | Shanghai China (Mainland) | Brand Name: | cnbm | Model Number: | Aluminum Flexible Range Hood Vent duct |
Type: | Ventilation | material: | 2 piles aluminum foil and sprial wire | size: | customized |
length: | 4m | diameter: | customized Aluminum Flexible Range Hood Vent duct | application: | range hood ,ventilation kit |
fire resistant: | Class B1 (GB8624) | flexible and compressible: | 10:1 | Temperature range: | -30°C ~+140°C |
Max air velocity: | 30M/S | Working pressure: | 2500Pa |
Packaging & Delivery
Packaging Detail: | single cardboad box Aluminum Flexible Range Hood Vent duct |
Delivery Detail: | 15 days after deposit Aluminum Flexible Range Hood Vent duct |
Specifications
Aluminum Flexible Range Hood Vent Kit Duct
1 .size customized flexible pipe
2. fire resistant
3. for range hood
Aluminum Flexible Range Hood Vent Kit Duct Specifications:
1 Expandable aluminum ducting,aluminum foil ventilation ducting
2 Fire retardant,connect to absorber with clamps
3 diameter customized
Materials:
Two layers of aluminum foil reinforced with high tensile spring steel wire
Number of piles is up to customer's requests
Features:
1 Heat and fire resistant: Class B1 (GB8624)
2 Highly flexible and compressible: rate: 10:1
3 Max air velocity: 30M/S
4 Working pressure: 2500Pa
5 Temperature range: -30°C ~+140°C
Applications:
1 Ideal for range hood
2 As ventilation hose for equipments
- Q:wiring diagram
- Hunter Ceiling Fan Wiring Diagram
- Q:i have an amp (sony xm 2002gtr) that says it requires 4 gauge wire..but they cost $100+ and i have plenty of 8 gauge wires. can i use two 8 gauge wires as a substitute for one 4 gauge wire?and also, i have my capacitor grounded to unpainted metal of my car AND the ground port of my amp..is that incorrect?
- Two 8-gauge wires combined are equal to a 5-gauge wire, but that should be close enough for that amp. Make sure each wire has its own fuse near the battery; 40-amp fuses would be a good choice. If you capacitor is connected to ground, and your amp is grounded, then you don't really need a wire between the capacitor's ground terminal and the amp's ground terminal. It doesn't hurt anything, though. If the only ground wire at the amp is the one that runs to the capacitor, then you're better off connecting the amp ground directly to chassis metal.
- Q:You have a 3 foot wide wire, vs a .3 inch wire. They are equal length. There is 3 volts going through each wire, to power your 1 volt LED. So, would the 3 foot wide wire have less resistance ? I don't even think it would work.
- Because there are a lot more electrons available in that ridiculously large wire.
- Q:have 0 gauge power wire, but don't have a ground wire! can I use the power wire as a ground wire if I cut a piece off?
- The only difference between ground wire and power wire is the color of the jacket. Otherwise it's identical. If you have leftover power wire, go ahead and use it for the ground. Just wrap some tape around the end so you can tell it from the power wire if you need to disconnect and re-connect the amp.
- Q:ok...all the wires in my quot;atticare encased in this silver metal casing....when i opened a bathroom wall...the wires were also like that.....at the fuse box...they all leave like that........sooooo, can i assume all my wires are encased like that? does that make them pretty safe from rodents chewing? (yup-been watching Billy the Exterminator) why were they done like that? tx for any info....
- In the U.S. it WAS called BX and is now called MC, standing for metallic clad. (If the lines are flex-able). This stuff was used to protect from damage. This is usually used in commercial applications, but is perfectly legal (if the proper connectors were used) in residential applications. It sounds like you are doing a remodel. If so, you will need a EXPERIENCED electrician to modify the runs for you. Don't let anyone tell you it is against code. It is simply overkill.
- Q:My father changed out a 3 prong plug to a 4 prong plug and crossed the wires by mistake. So the red wire on the plug was connected to the black wire to the dryer and visa-verse. What would happen to the dryer if it is turned on with these wires crossed? Consequently, my dryer's motor is not responding, however the heating element is working. Was there a short? Did the motor get fired?
- My first question is did he run a new line ? With the old three prong, there was only three wires. There shall be four wires to use a four prong. So, if he didn't and plugged in the dryer in, any warranty is null and void. As far as the black and red being crossed, no it does not matter with these two wires.
- Q:other than soldering and using a T-tap (wire tap), what are other common ways of connecting two wires together? Also, what does the following video say at the 1 minute 10 second mark? It's a something-set that helps to attach wires.
- Synyster Gates is on your record yet Chuck Schukdiner, Dave Mustaine, Marty Friedman, Tony Iommi, Jeff Waters, and Alex Skolnick are not? accurate 10 maximum proper metal Guitarists. a million. Chuck Schuldiner 2. John Petrucci 3. Steve Vai 4. Marty Freidman 5. Dave Mustaine 6. Jeff Waters 7. Joe Satriani 8. Alex Skolnick 9. Ol Drake 10. Tony Iommi Chuck and Jeff are very Skillful and their kinds are unique. have you ever heard of lack of life or Annihilator, Synyster Gates is mediocre and tries to play like Kirk Hammett, he's a propose Guitarist and all his solos sound an same. please tell me how can Synyster Gates be extra effective than Chuck and Jeff Waters provide me causes.
- Q:I have a 98' F-150 and need to add a 4 flat trailer wire connector to it. What all do I need to do? Is their a special connector?
- Your friendly neighborhood auto parts store should have a wiring kit for your truck... complete with instructions and diagrams.
- Q:I notice my 10/100 Ethernet wire uses 4 wires (2 twisted pairs). I'm curious what each wire is used for. I understand one pair is for Tx (transmit) and the other for Rx (receive) but why does it need 2 wires for each? I assume bits of data cross on one, but what of the other?
- Your okorder /
- Q:why do we use copper wires as connecting wires
- copper has a physical property that is a very good conductor of electricity.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
flexible insulation air duct expandable flexible insulation air duct High-tensile steel wires