Flake Graphite With High Purity And Good Quality

Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
50 m.t
Supply Capability:
5000 m.t/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Flake Graphite With High Purity And Good Quality


High-purity graphite,
High carbon graphite,
Medium carbon graphite.


Crystalline flake graphite is widely used as an essential nonmetallic material in almost all industries. It can be used as high quality refractory material or coatings in metallurgical industry, black lead in light industry, and carbon brush in electronics industry, electrode in battery industry and catalyst in chemical fertilizer industry. After being deep processed, crystalline flake graphite can be used to produce TV tube coatings, graphite friction reducing additives and many other high tech product.


Perfect crystallization, thin flake, good flexibility, excellent chemical and physical properties, superior conductivity, self lubricity and resistance to temperature, corrosion and hot shock etc.






Medium Carbon

High Carbon

High Pure






45 μm-500 μm   (325mesh-35mesh)








Black Shiny,




Flake Graphite With High Purity And Good Quality

Flake Graphite With High Purity And Good Quality

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How is grade of fire endurance divided?
Fire resisting shutter is divided into Class A / B / C, and the relevant fire endurance are not less than 1.2 /0.9 /0.6 hours, see "General technical conditions for steel fire resisting shutter GB 14102-93". 4.3 4.3.1 Classification according to time of fire resistance 4.3.1 Ordinary steel fire resisting shutter (see Table 3) Table 3 and Category Code Refractory time hF1 1.5F2 Composite steel fire resisting shutter (see Table 4). Table 4 and Category Code Refractory time hF3 2.5F4 3.04.4 Classification according to refractory time and smoke prevention performance 4.4.1 Ordinary steel fire and smoke resisting shutter (see Table 5) Table 5 category and code refractory time h smoke leakage (20Pa differential pressure) FY1 1.5 ≤0.2m3 / m minFY2 2.0 ≤0.2m3 / m min4.4.2 composite steel fire and smoke resisting shutter (see table 6) table 6 category and code refractory time h smoke leakage (20Pa pressure) FY3 2.5 ≤0.2m3 / m minFY4 3.0 ≤0.2m3 / m min Excerpt completed. Fire shutter used as fire compartment has a fire resistance of 3 hours, and fire shutter set on the upper opening part on the firewall has a fire resistance of 1.2 hours. **** Materials with fire resistance of 3.0 hours are called AAA refractory material (back fire surface). "Building Conventions" have mentioned in places where it is really difficult to set a firewall, fire shutters can be used to separate fire compratment. When using fire shutters whose back surface temperature rise is included as the judging criteria of fire resistance, its fire resistance should be not less than 3.00h; When using fire shutters whose back surface temperature rise is not included as the judging criteria of fire resistance, independent protection of closed automatic water spraying system should be set on the both sides of the shutter, and the duration of water spray should be not less than 3.00h. In summary: Fire shutter is divided into: Grade AAA, A, B and C
Q:The principle of choosing fire-resistant material in Thermal Energy and Power Engineering equipment.
Different thermal technology equipment has different operation condition and select different refractory material. We should take economical and practical as principle.
Q:What's the material of fireproof and wear-resisting floor?
1. It is the kind of special concrete floor, and its production process is the same with that of the common concrete floor, but it uses different material which needs to be the pebbles and sand after processing with marbles and dolomite. 2. Fireproof floor is a kind of decorative material which is laid on the ground of the factory or large areas of floors. It does not support combustion or it is composed of flame retardant materials. Fireproof floor has two categories. One is composed of aggregate wear-resistant material which is solid particulate matter. Its construction method is to evenly spread aggregate wear-resistant particles on the surface layer of the concrete when the floor is just pouring concrete and solidified, and then a firm flame retardant layer will be formed on the surface layer. This is the the so-called carborundum wear-resisting floor. But this kind of material has many limitations and can only be used on the surface of the just poured concrete. In addition, it is easy to fade in color and not beautiful in appearance. So this is not fireproof floor in the strict sense. Here we focus on a new liquid coating fire protection floor, which is environment friendly, widely used and beautiful in appearance. 3. Wear-resistant floor has the characteristics of pressure resistance, strong wear resistance,oil resistance, and anti-infiltration. It is also dust-free and easy to clean. After entering the initial setting of concrete, construction can be started immediately. Construction period is usually longer, but better using effect will arise.
Q:what's the fireproof levels of fireproof and thermal inuslation matertial?
1, organic materials: B level material is flammable, B1 level material is flame retardant. 2, inorganic materials: Grade A flame-resistant materials are divided into three classes and two kinds of materials.
Q:Which kind of external wall fire barrier zone material is better?
I recommended foam cement and particulate thermal insulation composite waterproof material, which is fire isolation area product, which uses surface of vertical plate arranged fiber technology to make the compressive strength in the vertical direction up to above 80KPa. At the same time, under the conditions of both exterior heat insulation and effects of humiture in the long-term, it can still maintain the non-aging performance of various aspects, and safety (reliability), fire resistance and excellent durability.
Q:Can anyone say something about the curtain wall fire-proof material key sealing point?
When sealing the gaps between glass curtain wall and floors of all layers and the outer edge of the partition with rock wool or mineral wool, its thickness should not be less than 100mm and should be filled densely; Rock wool or mineral wool for horizontal smoke prevention zone between floors should use galvanized steel sheet whose thickness is not less than 1.5mm to support; The gaps between supporting plate, major structure, curtain wall structure and supporting plate should be filled with fire-resistant glass, whose fire endurance should meet the design requirements. Fire-resistant glass for curtain wall are mainly include monolithic fire-resistant glass as well as the hollow glass and laminated glass made by monolithic fire-resistant glass.
Q:What are included in wall fireproofing material?
External wall thermal insulation materials are divided into A and B according to combustion level. Grade A is incombustible material, while grade B is combustible material. A few years ago, fires in CCTV building and Shenyang hotel resulted from grade B material. Currently grade A is usually used, and some are even cheaper than the grade B material. Grade A is roughly divided into insulation mortar, phenolic board, rock wool board, foam cement board, etc. Insulation mortar is quite good. It is easy and convenient to construct, has low cost, but the production is too simple and it is easy to fake.
Q:which kind of material is chosen for fireproofing window?
(1) the inside filler material of steel, wood frame should use incombustible material. (2) window frame uses steel frame or wooden frame with certain strength that can safeguard the integrity and stability of the components. (3) steel frame and mound layer can choose galvanized steel sheet or stainless steel plate. Its selection criteria conform to the article 5.1 in GB12955 Steel Fireproof Door General Technical Condition. (4) the selection criteria of wooden frame and mound layer should conform to the article 5.1 in GB12955 Wooden Fireproof Door General Technical Condition. (5) fire-resistant glass can choose test approved products without affecting the fire resistance of fireproofing windows . Light transmittance of glass should not be less than 75% of same layers commom sheet glass. (6) the sealing material between the frame and the fire-resistant glass should use flame retardant materials, it can play a role of fireproofing and smoke insulation in the fire. (7) hardware accessories should be tested qualified approved supporting product.
Q:What kinds of refractory materials that uses a-Al2o3 powder? What are the purpose of it?
04La-Al2O3 powder is a alumina powder whose raw material is industrial aluminum oxide which has been calcined at high temperature. It is a good polishes for ceramics and jade, meanwhile, it is also an important raw material for high-end refractory materials. The technical indicators parameters A1023 mark A1535 chemical composition AL2O3≥ 99.92 3%, ≥ 3.10FE203≤ 0.799 Refractory calcined alumina powder (a-Al2O3) 1.2 true density (g & # 47, by fully ground powder made of different fineness .O.10 0.07 0.04NA2O≤ 0.93a-Al2O3 (%) ≥ 95 95 primary crystallization average grain (um) 2 ~ 3 3 ~ 5 average particle size (um) 40 ~ 602.6SIO2≤ 0.1 0.15B2O3≤ - 0, glass, engineering ceramics typical use electronic ceramic insulating ceramic refractory ceramic wear 3
Q:How should fireproof building materials be ranked?
5. Civil building 5.1. Fire resistance rating, number of layers and floorage of civil buildings 5.1.1. Fire resistance rating of civil buildings should be classified into four levels of first, second, third and fourth. Unless otherwise specified in the code, the combustion performance and fire endurance of building components with different fire resistance rating should be no less than that of the regulations in Table 5.1.1. Table 5.1.1: Combustion Performance and Fire Endurance (h) of Building Components (Figure) Note: 1. Unless otherwise specified in the Code, the fire resistance rating of the building with wooden pillars as load-bearing and incombustible material as the building wall should be the fourth level; 2. For the suspended ceiling of the building with the second level of fire resistance rating, if it uses non-combustible component, it won't be limited in its fire endurance; 3. For buildings with the second level of fire resistance rating, if it is really difficult for the partition wall of rooms with the area of no less than 100m2 to implement the regulations of the Table, the partition wall can adopt the non-combustible component with fire endurance of no less than 0.3h; 4. For buildings with the first or second level of fire resistance rating, if it is really difficult for the partition wall of both sides of the evacuation walk to implement the regulations of the Table, the partition wall can adopt the non-combustible component with fire endurance of no less than 0.75h. 5. Fire endurance and combustion performance of the residential building component can be implemented in accordance with the provisions of current national standard GB 50368 "Residential Building Code".

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range