Product Description:

Quick Details of Fire Hydrant

Material:

cast iron / ductile iron.

Work Pressure:

PN16

Size:

DN80,DN100

 

Specifications of Fire Hydrant

Breakable Landing Fire Hydrant
1)Item: breakable landing hydrant
2)Size: DN80-DN150.
3)Work pressure: PN16

Breakable Landing Fire Hydrant

1)Size: DN80, DN100.

2)Work pressure: PN16.

3)Material: ductile iron, cast iron

4)Color: blue color,black color,red color,gray color,etc.

  

The Technical Parameters of Fire Hydrant

 

Item No.

Common Type

Landing Hydrant

SS100/65

SS150/80

Underground Hydrant

SA65

SA100/65

SAD100/65

Breakable Type

SSF100/65

Prompt Open Type

SSK100/65

Nominal Diameter(mm)

 DN100       DN150

Nominal Pressure(MPa)

 PN1.0        PN1.6

Strength Test Pressure(MPa)

        1.5

Open Height(mm)

≥50

≥55

≥50

Applicable Medium

Clean water, foam liquid

 

Packaging & Delivery

Packaging Detail:1PC/CTN

Delivery Detail:20-50days

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the types of fire hydrants on the back of the fire hydrant?
Dark installed through the fire hydrant box, back to hang barbed wire, wipe 5mm cement. Fireproof board is nonflammable material, can not be used as fireproof partition.
Q:How to use indoor hydrant
When a fire occurs, found from the nearest fire hydrant, open the door of the fire hydrant box, remove the hose, the hose is connected to the fire hydrant outlet, the other end is connected with the water, pull to the fire point near the rear can open the hydrant valve, when the fire pump control cabinet is in automatic state directly pressing the button to start the fire hydrant fire pump.
Q:What is the distance between fire hydrants?
The spacing of indoor fire hydrants in high-rise buildings (warehouses), elevated warehouses and armour and class B buildings shall not be greater than 30m;
Q:Does the hydrant shift require the whole system to drain off water?
Is generally not needed, in the fire hydrant system network, design of the valve, as long as the fire hydrant to be shifted off the corresponding water supply pipe valve can be placed on the realization of local water hydrant maintenance or displaced.
Q:Can fire hydrant decoration be packed with material?
1, the fire hydrant should be placed in the corridor or hall of public space, usually in the space inside the wall, no matter what kind of decoration on the requirements of the eye-catching label (marked "fire hydrant"), and shall not set up obstacles in its front, to avoid the impact of open fire hydrant door.2, fire hydrants in the room (such as box), does not meet the fire regulations, but also against the timely rescue of firefighters.
Q:Why are fire hydrants equipped with fog nozzles?
The water mist spray gun can also effectively control the concentration of pulverized coal in the air, and can effectively prevent dust explosion. The place where coal is produced and ground is a kind of production place, and it is easy to cause dust explosion when sparks are encountered.
Q:How many fire hydrants should there be in the city?
The outdoor fire hydrant (DN100) protection radius of 150 meters, however, high-rise buildings, the radius of protection by blocking, set or several adapters should each building along the street. At present, there is no index according to the urban area allocation.
Q:Has the hydrant been discharged from the main engine?
There is no high water tank and voltage regulator, will not start the pressure regulator pump. If yes, it will start the constant pressure pump.
Q:Why did the fire hydrant say "HR"?
HR, abbreviated as "Hose Reel" or "Hydrant Reel", is the English name of fire hydrants.
Q:How to fill in the static pressure and dynamic pressure in the fire hydrant test records in fire control engineering?
This is not calculated in your project completion and acceptance, there is a fire hydrant fire brigade specialized testing tools (water gun connected to the pressure gauge), it is not the first static test, the test pressure in the pipe network, the general should not be greater than 1.0MPA.
CFXFIRE, i products sell well in Europe, North and South America, Africa and the Middle East and Southeast Asia with it's good price and good service

1. Manufacturer Overview

Location Fujian, China
Year Established 2008
Annual Output Value Above US$ 1 Million
Main Markets North and South America, Africa and the Middle East and Southeast Asia
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shengzhen
Export Percentage 40%
No.of Employees in Trade Department 200 People
Language Spoken: English; Chinese; Spain; Alabic
b)Factory Information  
Factory Size: Above 60,000 square meters
No. of Production Lines 4
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range Average