Fire Fighting Water Pump with XBD Series

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

                             Fire Fighting Water Pump with XBD Series

 

1.Structure of Fire Fighting Water Pump with XBD Series Description

PLC Control Non-negative Pressure Water Supply Equipment is a high efficient  water facility has characters of easy installation,saving space, water pool is not required.The pump energy efficient, using I mm converter speed control valve control over a large number of energy saving, the elimination of the high level of secondary pollution of water tanks,water tank eliminates the need to wash the cost and trouble,Water Pump achieve soft-start, start on the grid to reduce the impact of pumps to extend life.

 

2.Main Features of the Fire Fighting Water Pump with XBD Series

  • Water Supply: Urban water supply, boiler or condensate system, water filtering and distributionwater to water districtin charge of pressurizedhigh-rise building pressurization.

  • Industrial boosting: process water systemcleaning systemhigh pressure washing systemfire system.

  • Industrial liquid conveying: cooling and air conditioning systemsboiler feed and condensate systemsmachine matchingacid and alkali.

  • Water Treatment: Industrial circulating system and processing system, environmental protection water treatment and infiltration analysis system, Ultrafiltration systemsreverse osmosis systemsdistillation systemsseparatorsswimming pool

  • Irrigation: Agriculture irrigation and dewatering, sprinkler irrigation, drip irrigation.

3.Fire Fighting Water Pump with XBD Series images

Fire Fighting Water Pump with XBD Series 

4.Fire Fighting Water Pump with XBD Series Specification

 

modelcapacitypressurespeedeffeciencypowernpsh
(L/s)(MPa)(r/min)(%)(Kw)(NPSH)r(m)
XBD1.8/5-50W50.181450652.23.2
XBD2.7/5-50W50.2714506533.2
XBD3.6/5-50W50.3614506543.2
XBD4.5/5-50W50.451450655.53.2
XBD5.4/5-50W50.541450655.53.2
XBD6.3/5-50W50.631450657.53.2
XBD7.2/5-50W50.721450657.53.2
XBD8.1/5-50W50.811450657.53.2
XBD2.3/10-75W10231450685.53
XBD3.4/10-75W100.341450687.53
XBD4.6/10-75W100.46145068113
XBD5.5/10-75W100.55145068113
XBD6.9/10-75W100.69145068153
XBD8.0/10-75W100.8145068153
XBD9.2/10-75W100.9214506818.53
XBD10.3/10-75W101.0314506818.53
XBD2.9/20-100W200.29145072113.5
XBD4.3/20-100W200.43145072153.5
XBD5.8/20-100W200.58145072223.5
XBD7.2/20-100W200.72145072303.5
XBD8.6/20-100W200.86145072303.5
XBD10.1/20-100W201.01145072373.5

XBD11.5/20-100W

201.15145072453.5
XBD13.0/20-100W201.3145072453.5
XBD4.2/25-125W250.42145073223.5
XBD6.3/25-125W250.63145073303.5
XBD8.4/25-125W250.84145073453.5
XBD10.5/25-125W251.05145073553.5
XBD12.6/25-125W251.26145073753.5
XBD14.7/25-125W251.47145073753.5
XBD16.8/25-125W251.68145073903.5
XBD18.9/25-125W251.89145073903.5
XBD5.8/45-150W250.58145073453
XBD8.7/45-150W250.87145073753
XBD11.6/45-150W251.16145073903
XBD14.5/45-150W251.451450731103
XBD17.4/45-150W251.741450731353
XBD20.3/45/150W252.031450731553
XBD23.2/45-150W252.321450731803
XBD26.1/45-150W252.611450731803

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Harm of air pump and pump
If the liquid is not full, this situation is generally the suction pipe or pump shell leakage, then easy to cause cavitationHit the pump for centrifugal pumps, centrifugal pump is recommended to start closed, the discharge valve closed, starting is in the state of pump
Q:Variable flow pumps are variable pumps
Variable input speed, the pump out of the flow is variable, it can not be said that it is variable pump.In a word。 A variable pump is a variable displacement pump.
Q:Hydraulic pump displacement refers to the pump shaft what?
You can see the sign of your hydraulic pump. There will be a displacement **ml/r in the sign of the hydraulic pump (r stands for every turn, ML is milliliter)
Q:What are the causes of pump shock?
6., water pump relatively serious cavitation, improve the water level of the water tank, reduce water output7., impeller and motor rotor imbalance, overhaul8. pump shaft bending or abrasion overhaul
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
(1) the pellet dose in the safety standard of the infusion pump refers to the amount of liquid that is transported to the patient in a short period of time(two) pill dose limit is mainly to control the risk of accidental pill dosage. Especially after the mandatory requirements of pipe blockage in the elastic pipe storage liquid limit amount of agglomeration and the limitation of these methods to release pill dose.
Q:Metering pumps related matters
Rotate to stroke length 100% position. This allows the kit to rotate to the back of the drain hole and align the bottom of the pump. Adjust the hydraulic end and diaphragm to the proper position during the pump operation.The duration of the pulse may not be long enough for the reaction time. With respect to the standard pulse width 80msec, the flow monitor pulse width expansion can be activated, increasing the pulse width to 300msec. Activate the smart switch, remove the cover fixed circuit board, remove the jumper X-1. This activates the extended function and allows more time before the failure instructions.Metering pump installed from the exhaust pump head, the use of self suction liquid imbibition. Keep the suction line as short as possible.
Q:Fire pump and shower pump flow head selection, high resolution.
3, larger than 25000, the minimum water consumption of indoor fire hydrant is 20L/s4, the minimum water consumption is the flow of a fire hydrant.
Q:Pump unloading in hydraulic transmission,
Can be used for short-term shutdown, pump non-stopNo unloading, usually through the overflow valve back to the tank, high pressure, power, at this time insurable pressure, and so on
Q:The distance from the pump button to the ground
After confirming that the fire pump has started running, issue a command signal to the hydrant button to light the green answer light.
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
- check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range