FERRULE PIPE END COMPRESSION CONNECTOR-ZINC

Ref Price:
$0.16 - 6.10 / pc
Loading Port:
Ningbo
Payment Terms:
TT or LC
Min Order Qty:
1000 pc
Supply Capability:
300000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

  These straight conectors are used on flexible metallic conduits.

Competitive Advantage: 
Straight connectors are designed to slip onto the conduit quickly and to grip the con-duit jacket, speeding up installation while ensuring a strong,liquid-tight seal that decreases the risk of pullouts. All com-ponents of these connectors can be easily disassembled and reused. Additionally, the included sealing washers provide liquid-tight seals when connectors are terminated in threadless openings. The heavy-duty locknuts included with every Topele liquid-tight connector ensure the continuity of the grounding. Connectors are zinc electroplated for excellent corrosion protection in damp locations.
  +Quick Delivery: within 30 days for one 20ft container.
  +Competitive Price
  + Good Quality: ISO/UL certificate approval
  +Best Service: fast delivery, strong package, good price, timely and effective communication
  +Powerful Solution: fast and effective solution to problem

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The difference between nylon balls and geese and ducks
As long as the cable is thick enough, 20 meters of the basic loss can be ignored.
Q:How to distinguish how many pairs of cable with a large heat shrink tubing
Cable bridge grounding should belong to the protective grounding, grounding resistance at a cross point is not greater than 50 milliohms, no jumper no more than 5 milliohms
Q:What is the type of pipe that is marked as KBG pipe?
Will the general power cable control cable can do the largest square...
Q:How much of the cable with the switch?
The switch is not selected according to the cable and is selected according to the current. The cable is determined by the size of the power (converted to current) and the distance from which the distance is far. The greater the power distance, the greater the cross-sectional area of the required cable. For example: 15KW motor selection cable current I = P / 1.732UcosΦ = 15 / 1.732 / 0.38 / 0.8 = 28A if it is close (within tens of meters), copper cable 6 square millimeters, aluminum cable 10 square millimeters. If it is in the distance (a few hundred meters), copper cable 10 square millimeters, aluminum cable 16 square millimeters. If it is long distance (close to kilometers), copper cable 16 square millimeters, aluminum cable 25 square millimeters. The switch is regardless of distance, completely based on the load current to choose, generally according to the load current of 1.5 times to 2 times to choose.
Q:1000 kW 600 m cable to use much
Such a large load so far away, can only be transported with 10KY, near the installation of the transformer Caixing, if the 380V transmission, cross-sectional area, high cost, loss of large, not worthwhile. 10KV high-pressure delivery, current 55A, with 25mm² copper cable 35mm² aluminum cable delivery on it. If the 380V transmission, according to the line voltage loss simple calculation formula △ U% = PL / CS take △ U% = 5 copper cable S = PL / CS △ U% = 1000X600 / 77X5 = / 385 = 1558mm² aluminum cable S = PL / CS = U06 / 46X5 = / 230 = 2307mm² Line voltage loss △ U Simple calculation formula △ U% = PL / CS △ U% - Percentage of voltage loss P - Active power of conveying (Kw) Distance of L- M) C-constant, aluminum single-phase 8.. aluminum three-phase four-wire 46; copper single-phase 12.. copper three-phase four-wire 77S-conductor cross section (mm²) (quoted from "electrical entrance permit test low pressure Class theory "" electrical engineering basis ")
Q:5 air conditioning can be used 4 square cable
You do not use the 9V power supply, a long time will burn the router.You'd better measure the original adapter voltage, if you want to extend the power cord, it is best to use a thick line of reliable connection, you can not start now, you can not start Depending on whether the extension line is too thin, causing the voltage drop too much.It is necessary to extend the front end of the adapter can extend the 220V power cord.
Q:7 kilowatts of electricity with what specifications of the wire
1 square millimeters can flow 4A current, 1KW380V, then the current is about P = UI about 2.6A7KW, 380V, then the current is about 18A, each with the line to share 18/3 = 6A2.5 square mm of copper on it. Of the area need to take . probably 6 level. V is probably 7KW220VI = p / u = 7000/220 = 31A. Then need 10 square millimeters of copper.
Q:25 square copper cable how much money one meter?
Copper should be more than 2.7 flat. Aluminum to 4.5 or more.
Q:Apple 6 Charging Why always show this cable has not yet been certified
Is the power directly out of the CPU power supply line or on this basis and added the extension line
Q:Is the cable head made of every building?
Generally have every building floor wiring closet must be connected to the big cable. The big cable comes in to do the cable head

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range