FEMALE FLEXIBLE CONDUIT CONNEXTOR-ZINC,watertight connectors

Ref Price:
$0.16 - 6.10 / pc
Loading Port:
Ningbo
Payment Terms:
TT or LC
Min Order Qty:
1000 pc
Supply Capability:
300000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Description:
Female Flexible Conduit Connector-ZINC
Material: Zinc Alloy
For the connecting of flexible pipe, metal pipe or equipment
Waterproof, protect wire safety.
Male Straight Pipe Fitting, galvanized threaded type, is die casted-of zinc alloy with zinc plated on its surface.
Can offer chrome or nickel pated for a smoother surface.
Reliable quality
Stable perfermance
Size: 1/2"-4"

Competitive Advantage: 
   JIACHI’ straight connectors are designed to slip onto the conduit quickly and to grip the con-duit jacket, speeding up installation while ensuring a strong,liquid-tight seal that decreases the risk of pullouts. All com-ponents of these connectors can be easily disassembled and reused. Additionally, the included sealing washers provide liquid-tight seals when connectors are terminated in threadless openings. The heavy-duty locknuts included with every Topele liquid-tight connector ensure the continuity of the grounding. Connectors are zinc electroplated for excellent corrosion protection in damp locations.
  +Quick Delivery: within 30 days for one 20ft container.
  +Competitive Price

  + Good Quality: ISO/UL certificate approval
  +Best Service: fast delivery, strong package, good price, timely and effective communication
  +Powerful Solution: fast and effective soluti

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The difference between nylon balls and geese and ducks
If the 2.5 square copper wire for the output extension cable, 20 meters distance, the total resistance of about 2 * 1.7 * 0.2 / 2.5 = 0.272 (ohms), the current maximum 1.8A, the voltage drop is 0.272 * 1.8 = ), The charging voltage is 55-0.5 = 54.5 (volts), a difference of about 1% will not have any impact on the battery. However, the third floor, said Ye Hao, you can put the charger put the debris room, from your house put a 220V power cord down, home and then engage in a switch control. It is best to design a light at home, can intuitively see if the electricity is full. That's better. Design light, teach you a way: to find a bad leakless protector, open there is a coil-like ring-shaped stuff, called zero sequence current transformer, it will be down, be careful, do not put Transformers inside the coil hurt, get down, in the transformer two thin lines connected to a light-emitting diode. And then your 220V power cord line of fire from the center of the sensor through, around 3-5 turns. In this way, as long as there is current flow, the light-emitting diode will be bright, when the charge is over, the charging current is close to zero, the light-emitting diode will be extinguished. You can from the light-emitting diode is lit to determine whether the electric has been filled. I also have an electric bike that is so charged.
Q:Decoration doubt, what kind of wall can not open the horizontal groove?
Excretion training is the use of positive reinforcement, that is, a variety of food, toys, the best time to reward
Q:What is the type of pipe that is marked as KBG pipe?
The best cement and other dry in the closing, because the wet cement contains moisture, can be conductive, dry the probability of conduction less. Pay attention to the wire to maintain integrity, no broken skin, it is best to protect the casing.
Q:How to solve the computer connected to the TV audio problem, how to set the computer and TV audio separation
In accordance with the relevant safety regulations, the power cable should not be parallel to the top of the thermal pipe laying, when can not be avoided, the interval distance should not be less than 1000mm, during which should also take effective insulation measures. Power cable and thermal pipe cross, the thermal pipe insulation layer, the separation distance should be not less than 500mm, no insulation layer should not be less than 1000mm, and in the cross with the insulation board to be protected, the length of the insulation board should not be less than d + 2000mm (d for the thermal pipe insulation layer diameter).
Q:1000 kW 600 m cable to use much
Such a large load so far away, can only be transported with 10KY, near the installation of the transformer Caixing, if the 380V transmission, cross-sectional area, high cost, loss of large, not worthwhile. 10KV high-pressure delivery, current 55A, with 25mm² copper cable 35mm² aluminum cable delivery on it. If the 380V transmission, according to the line voltage loss simple calculation formula △ U% = PL / CS take △ U% = 5 copper cable S = PL / CS △ U% = 1000X600 / 77X5 = / 385 = 1558mm² aluminum cable S = PL / CS = U06 / 46X5 = / 230 = 2307mm² Line voltage loss △ U Simple calculation formula △ U% = PL / CS △ U% - Percentage of voltage loss P - Active power of conveying (Kw) Distance of L- M) C-constant, aluminum single-phase 8.. aluminum three-phase four-wire 46; copper single-phase 12.. copper three-phase four-wire 77S-conductor cross section (mm²) (quoted from "electrical entrance permit test low pressure Class theory "" electrical engineering basis ")
Q:5 air conditioning can be used 4 square cable
Lengthened low voltage side, the line resistance increases, the voltage drop increases. Reduced load capacity. So that the router due to insufficient supply voltage and can not work properly. It is not allowed to use 9V power supply. Voltage is too high, the router part of the internal power supply increased power, heat increased, it is possible to burn the router. It is necessary to extend the power cord, I suggest you extend the power supply side (220V one end) safe and reliable. Increase the voltage to increase the supply current, in the electrical working voltage range (with the electrical work voltage range) is allowed, too low electrical appliances can not work properly. Too high there is the risk of burning appliances, according to your actual situation, marked 5V0.2A that the router works at rated voltage, so the way to improve the supply voltage is not applicable. So you can only improve the power supply power (that is, you say to increase the power supply current rather than voltage). With the reserve power, it will provide enough current at the rated voltage (the router as a resistor, from I = U / R, you can know the danger of increasing the voltage) need help please message
Q:7 kilowatts of electricity with what specifications of the wire
1 square millimeters can flow 4A current, 1KW380V, then the current is about P = UI about 2.6A7KW, 380V, then the current is about 18A, each with the line to share 18/3 = 6A2.5 square mm of copper on it. Of the area need to take . probably 6 level. V is probably 7KW220VI = p / u = 7000/220 = 31A. Then need 10 square millimeters of copper.
Q:25 square copper cable how much money one meter?
There is no 1..2..4.5 square wire. The family uses most of the four wires with 1.. 1.. 2.5 and 4. Power 1KW Approx. 5A.3KW Approx. 15A.2.5 square copper wire can be used. Plug or empty open (25A).
Q:Apple 6 Charging Why always show this cable has not yet been certified
Is the power directly out of the CPU power supply line or on this basis and added the extension line
Q:Is the cable head made of every building?
Generally have every building floor wiring closet must be connected to the big cable. The big cable comes in to do the cable head

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range