FC bauxite base Casting mass for Blast lining

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
25 m.t.
Supply Capability:
10000 m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Place of Origin:

Liaoning, China (Mainland)

Shape:

Powder

Material:

high quality bauxite and sic

SiO2 Content (%):

/

Al2O3 Content (%):

70

MgO Content (%):

/

CaO Content (%):

./

Refractoriness (Degree):

Common (1580°< Refractoriness< 1770°)

CrO Content (%):

/

SiC Content (%):

10

Model Number:

CNBM

Brand Name:

DDER

Colour:

black

addvantage:

ISO9001:2008



Packaging & Delivery

Packaging Details:50kg/bag,1000-1250kg/jumbo bag



 FC bauxite base  Casting Material for Blast lining 

 

Manufacture :

      1. Used excellent Bauxite ,graphite and pitch as raw material ,

      2. Add excellent bander

      3. Mix according to the granularity distribution.

 

Products feature:

      1.Mixed evenly, not loose 

      2.High refractoriness , 

      3.Excellent resistance for erosion.

 

Application :

 

        Mainly used for the working lining  of  runner for Blast Furnace .

 

Index:

 

Item

index

Al2O3                                                       %

70

SiC                                                           %

10

Bulk density

110X24h      g/cm3

2.8

1450x3h      g/cm3

2.7

Cold  Breaking strength

110X24h        Mpa

8

1450x3h        Mpa

10

Cold Crushing strength

110X24h        Mpa

40

1450x3h        Mpa

45

Linear change

1450x3h          %

±0.3

 

 

FC bauxite base Casting mass for Blast liningFC bauxite base Casting mass for Blast lining


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Can anyone say something about the curtain wall fire-proof material key sealing point?
When sealing the gaps between glass curtain wall and floors of all layers and the outer edge of the partition with rock wool or mineral wool, its thickness should not be less than 100mm and should be filled densely; Rock wool or mineral wool for horizontal smoke prevention zone between floors should use galvanized steel sheet whose thickness is not less than 1.5mm to support; The gaps between supporting plate, major structure, curtain wall structure and supporting plate should be filled with fire-resistant glass, whose fire endurance should meet the design requirements. Fire-resistant glass for curtain wall are mainly include monolithic fire-resistant glass as well as the hollow glass and laminated glass made by monolithic fire-resistant glass.
Q:Fefractory of aluminium oxide.
It can be refined into castable refractory and refractory bricks, according to temperature rating. There are shaped refractory material and shapeless refractory material, and ceramic fiber. So it must be specific. There is a large range of refractory, which basically contains the aluminium oxide.
Q:How to distinguish the fire resistant level of the rubber and plastic thermal insulation material?
It is divided into level A, B1, B2 and B3. According to the current "burning behavior of building materials classification method", Level A insulation material is a non-combustible material, which belongs to YT. However, from the point of view of the current market , level A insulation material are very few, only glass wool, rock wool board, foam glass and vitrified micro bead. However, compared with level A insulation material, the more welcomed by the market is the organic insulation material. This is characterized as thermal insulation material, which is divided into three levels: level B1 is flame retardant, level B2 is flammable and level B3 is flammable. The level B1 nonflammable thermal insulation material is determined according to the fire endurance of the material. And different parts of the material are divided differently! Such as the common EPS / XPS insulation boards through special treatment of adding flame retardant. . Level B2 combustible insulation material is commonly the EPS expanded polystyrene foam insulation board and XPS board, that is, the ordinary plate. This material has low ignition point, and releases large amounts of harmful gases in the combustion process . Level B3 flammable insulation material is commonly the thermal insulation material taking polystyrene foam as the main material. Since this material is highly flammable, it has been out of the external wall thermal insulation materials. As for the civil construction insulation materials, China's current popular building insulation materials in the market are mainly made of three organic foams: EPS (molded polystyrene board), XPS (extruded polystyrene board) and PU (polyurethane).
Q:what should be paid sttention when buying the refractory?
First, look at the appearance of the product, it will be better if the surface of product is smooth, if there are the injuries and damages which may influence the use, do not use it. Second, the main characteristics of insulation material is flame resistance, reduce the loss of fire occurred at the time of purchase combustion performance testing products, non-combustible stone wool products are the best. Third, refractory insulation with good hygroscopicity is also very important, it can keep your room drying for a long time , played the role of moisture-proof, and more capillary, the hygroscopicity is better.
Q:what is the material of fixed first rate fire resistant window?
Fixed first rate fire resistant window is produced by the steel sash windows, steel casement, fireproofing glass. Fireproof windows, is composed by steel window frame, steel casement, fire-proofing glass. it refers to the window which can isolate and stop the fire spreading. The fire window product is named after the main material of window frame and the window casement, window frames is made of steel, casement is made of wood or the sash frame is made of wood and the casement is made of fire window.
Q:What is the difference between the fire rating and the fire resistant level of the fire-fighting equipment?
Fire rating and fire-fighting rating are the misnomer to the building fire resistant level. The building fire risk is measured by fire resistant level. The article 3.2.1 and 5.1.7 of "Architectural design code for fire protection" have made provision respectively on the fire resistant level of plant (the storeroom) and civil construction. Article 3.0.2 of "Code for fire protection design of tall buildings" has made provisions on the fire resistant level of tall buildings. Fire resistance rating of the building is divided into four levels. Standard of fire resistance rating is determined by the combustion performance and fire resistance of the main housing member. Level one or two are in accordance with the Article 1.0.2 in this specification.
Q:How is the development of Xinmi refractories industry? What's its advantages and disadvantages?
The advantages are largest scale, top production amout in the country, accounting for one-third of the national market, having technology, strength and the market. The disadvantages are the lack of mineral resources, serious environmental pollution,
Q:How much modulus is used as refractories material of sodium silicate.
Storage and use are very convenient, especially for mechanized and the evenly refractory material and the sodium silicatemodulus is generally...2. transportation. The appearance of product is pure white. Instant powdered sodium silicate, also known as instant sodium metasilicate.4 to 3, in powder form, automation. in the range of 3, hydrated sodium silicate
Q:Who knows about the criteria of fireproof and thermal insulation materials?
The standards of fireproof and thermal insulation material. 1. the height of buildings is greater than or equal to 100 m, the combustion performance of thermal insulation materials should be A-level; 2. the height of buildings is greater than or equal 60 m but less than 100 m, the combustion performance of thermal insulation materials should be no less than B2-level. When using B2-level thermal insulation materials, fire barrier zone should be set in each floor; 3. the height of buildings is greater than or equal to 24 m but less than 60 m, the combustion performance of thermal insulation materials should be no less than B2-level. When using B2-level thermal insulation materials, fire barrier zone should be set in every two floors; 4, the height of buildings is less than 24 m, the combustion performance of thermal insulation materials should be no less than B2-level. When using B2-level thermal insulation materials, fire barrier zone should be set in every three floors.
Q:What is the most reasonable drying heating curve of magnesia refractories? Products of less than 0.5T
You'd better oxidize magnesia preformed unit at room temperature for a longer period of time, then bake it, during which, it's enough to control the maximum temperature within 300 degrees. During the middle process, usually heating up for 4 hours and keep warm for 3 hours. The entire heating up process takes about 20 hours. If it is the site operation magnesia-based castable, it should be heated slowly in the early stage, and pay attention to keeping warm at 80 degrees Celsius. Every manufacturers has their own heating curves, so do not blindly adopt existing curves, try to make your own heating curve.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range