Factory price china yuchai diesel generator sets 630kw

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
300 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

open type dioesel generator with yuchai enginee 
1) Factory direct sale 
(2) CE, ISO9001 quality 

Power range

18-650KW

Engine

All series powered by Yuchai engine

Alternator

All series owning alternator options of Stamford/Marathon/ENGGA

Controller system

Hanging control box, automatic control module Smartgen HGM6310

Base frame

International channel steel welded base, inbuilt composite damping system; sandblast, acid-washing, antiseptic treatment

Radiator

Standard genset-joining radiator of 40 °C ambient temperature

 

 

Diesel generator Powered by Yuchai Engine,which yuchai is a large state-owned enterprise and a Nasdaq listed company in USA (NYSE:CYD). Its main business covers diesel engine, contruction machinery, vehicle parts. The engines produced by Yuchai include series YC6G, YC4G, YC4E to which American technology applied, series YC6A, YC6B, YC6J, YC4B, YC4D, YC4F, YC4W to which German technology applied, and YC6M series in which world top technology integrated, totally 12 series.

YUCHAI SeriesPower(KW)Power(KVA)Jichai Engine ModelCylinder NO.Fuel consumption
g/kw.h
DimensionL*W*HWeight  
 KG
FKS-Y630630200YC6G245L-D206≤1952500*970*15002300


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:If diesel engine generator stopped for long time, what the maintenance it needs?
First make sure the fuel is fresh periodically. Old fuel deteriorates makes it hard it start and run. Second check the oil see if it is clean, check the oil filter too. Third check the fuel filter, change once a year if not used because of bad / old fuel. Forth Check the out put of the engine / voltage / oil pressure / amperage / operating temperature / current fuses / transfer switches are working properly. Listen and make sure the engine is running smooth, no misses. Should be good to go then.
Q:Jackup Rig Power Distribution?
Nice to have your Q, i am also a Jack up Rig Design Engineer. Ok. see 1st of Jackup rigs have diesel generators which provide power supply for the various electrical power requirements on rig. usually the voltage level is 6.6kV, 4.16kV, 690V or 600 V which is then further reduced upto 415V, 220V/127V as per load and client requirements since it affects the design and overall space required and size of rig as well. the generated power is 1st transferred to the main PMCC or MCC known as generator switchboards. from here the power is dirtributed to various other switchboards such as jacking MCC, drilling MCC, Ventilation MCCs, VFD panels (for top drive mud pump panels through VFD/SCR system) and other MCCs for other electrical loads. voltage is further reduced upto 415V/220V/127V for lighting and other lv loads using dry type transformers. oil filled trafos are not preferred since they r bulky and not feasible to have them on rigs since its in sea and also problem in maintenance. cables used are usually of XLPE or XLPO insulation. the configuration is as follows CU/XLPE or XLPO/Inner sheath (SHF)/Armour/Outer sheath (SHF), the inner and outer sheath has to be low smoke halogen free material, armour is usually bronze wire armour, usually cables used are all flame proof as per iec 60332, cat 3-22A and cables for emergency purposes are fire resistant as per iec 60331. hope this is fine.
Q:how does a generator work?
Generators *always* take some kind of mechanical energy to operate. In the case of a power blackout, backup generators use large diesel engines rated for hundreds of thousands of Horsepower, to run the electrical backup generators. Those diesel engines (obviously) run on diesel fuel so, there is your 'anything'. .
Q:onan generator code 33?
If it has a waterpump you might need to change that.
Q:Who makes a good portable electric generator that burns diesel?
Honda Yanmar However, give Harbor Freight and Boats Harbors sales listings a look since it's not unusual to stumble upon a still in box surplus gen set.
Q:Which would be the most efficient and eco-friendly car type: Hydrogen, Electric, Diesel, Gasoline, Battery?
definitely okorder
Q:Any experienced Electrical Engineers out there?
Is it too late to switch to a 240 volt single phase generator of the same capacity? This would have a 60 amp capability and would handle the surges with no trouble. I don't see how a capacitor will help. If you are stuck with the 3 phase generator, perhaps you can switch the ACs for ones with 3 phase motors. That will spread the surge over the 3 phases. There are also soft-start ACs .
Q:i got 390 TONS OF REFRIGERATION OF PU,TOTAL 16 NO,HOW MUCH KW OR KVA REQUIRED DISEL GENERATOR TO RUN THIS,?
normally diesel generators are not used to run refrigeration units because of the high starting current of compressor motors 390 tons equals 1370kwatts or 1.37mega watts taking 30% extra you get 1.78 megawatts a 2 mega watts diesel generator should be considered
Q:How are diesel locomotives' engines started?
A diesel engine is started (like an automobile) by turning over the crankshaft until the cylinders fire or begin combustion. The starting can be done electrically or pneumatically. Pneumatic starting was used for some engines. Compressed air was pumped into the cylinders of the engine until it gained sufficient speed to allow ignition, then fuel was applied to fire the engine. The compressed air was supplied by a smallauxiliary engine or by high pressure air cylinders carried by the locomotive. Electric starting is now standard. It works the same way as for an automobile, with batteries providing the power to turn a starter motor which turns over the main engine. In older locomotives fitted with DC generators instead of AC alternators, the generator was used as a starter motor by applying battery power to it.
Q:Whats a good price for a back up power generator?
For used medium size portable temporary units about $100 to $150 US per KW. Plus the required transfer switch and permits and inspections if you intend to power your house with it. This is for a manual start gasoline powered unit. As you add options the price goes up and may triple in hurricane season in the path of the storm. The quietest unit I've found are Honda, but they are more expensive. Any unit smaller than 15KW should be considered a short term unit good for maybe 2000 hours of run time. A 15 KW unit should be a permanent installation with a mounting pad and at least a 7 day supply of fuel on site. For this a licensed qualified professional electrical contractor should be consulted. As convenient as they may be, they can get to be expensive to install and operate.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range