Etaline Z,Close-coupled, in-line twin circulator pump

Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
1 unit
Supply Capability:
10 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Close-coupled, in-line twin circulator pump, pump shaft and motor shaft are rigidly coupled.                                
Hot water heating systems, cooling circuits, air-conditioning systems, water and service water supply systems, industrial recirculation systems.

Overview of technical data

Type of impeller                                                                         Closed; Radial                    
Type of installation                                                                         In- line                    
Maximum drive rating                                                                         55                         kW                    
Impeller material (EN standard)                                                                         1. 4408;CC480K-GS;EN-GJL-250                    
Type of bearing                                                                         Ball bearings                    
Drive frequency                                                                         50 Hz                    
Maximum speed of rotation                                                                         2. 900                         1/min                    
Maximum flow rate                                                                         1. 095                         m³/h                    
Maximum discharge-side pressure                                                                         16                         bar                    
Suitable for drinking water                                                                         Yes                    
Casing material (EN standard)                                                                         EN- GJL-250                    
Casing material                                                                         Cast iron                    
Minimum flow rate                                                                         2                         m³/h                    
Suction characteristics                                                                         Non- priming                    
Drive voltage                                                                         Low voltage                    
eClass assignment                                                                         36410101; 36410100                    
Pump set location                                                                         Dry installed                    
Max. permissible fluid temperature                                                                         140                         °C                    
UNSPSC classification                                                                         4515150300                    
Main applications                                                                         Water; Building services;Industry and process engineering                    
Type of installation                                                                         Stationary                    
Type of casing                                                                         Volute casing                    
Type of connection                                                                         Flange                    
Type of lubrication                                                                         Grease lubrication                    
Type of drive                                                                         Electric motor                    
Installation position                                                                         Horizontal or vertical                    
Shaft material (EN standard)                                                                         1. 4571;C45+N                    
Type of coupling                                                                         Direct                    
Shaft seal type                                                                         Mechanical seal                    
Drive                                                                         Electric motor                    
Maximum head                                                                         38, 50                         m                    
Maximum rated pressure (discharge)                                                                         PN 16                    
Minimum head                                                                         2, 00                         m                    
Nozzle position                                                                         In- line                    
Connection to power supply                                                                         400 V, 3~                    

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range