ESP cable jacket includes NBR,compound of the neoprene and PVC, EPR, fluoroplastics

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Brief introduction

 

The product manufactured by us has the characteristics of advanced technology,reliable quality. The main manufacturing equipment is included the ROYLE Ф90 plastic extruder, the rubber continuous vulcanizing process, the interlocked armoring machine made by CEECO, Canada, the continuous sintering process imported from GRILLER, Austria, the Nokia cross-linked cable process, the advanced continuous annealing process and tinned process, etc. Now, the cable and coil end lead wire for submersible oil pump or pump unit can be produced, with different types and specifications, the cross-section of conductor is 42mm2 and below. The well temperature is from 50℃ to 180℃, the max. continuous working temperature of conductor is 204℃. The insulation material that can be used is as below: PP, EPR, polyimide-F46, fluoroplastics, XLPE, etc. The material of inner jacket includes NBR,compound of the neoprene and PVC, EPR, fluoroplastics, lea, etc. The outer sheath material is as the galvanized steel tape, stainless steel tape, etc. All kinds of cables for

submersible oil pump can be developed according to the customer’s requirements.

 

Brief type and size

 

Cable type

Description

Max working temperature℃

Product range (cross section)  mm2

QYPN

PP insulated and NBR sheathed, galvanized steel tape interlocked

armoring, cable for submersible oil pump

 

96

10、13、16、20、33、42

QYPNY

PP insulated and NBR sheathed, galvanized steel tape interlocked

armoring, round cable for submersible oil pump

 

96

10、13、16、20、33、42

QYEN

EPR insulated and NBR sheathed, galvanized steel tape interlocked

armoring, cable for submersible oil pump

 

140

10、13、16、20、33、42

QYENY

EPR insulated and NBR sheathed, galvanized steel tape interlocked

armoring, round cable for submersible oil pump

140

10、13、16、20、33、42

QYEE

EPR insulated and sheathed, galvanized steel tape interlocked

armoring, cable for submersible oil pump

 

175

10、13、16、20、33、42

QYEEY

EPR insulated and sheathed, galvanized steel tape interlocked

armoring, round cable for submersible oil pump

 

175

10、13、16、20、33、42

QYEQ

EPR insulated and lead sheathed, galvanized steel tape interlocked

armoring, cable for submersible oil pump

 

204

10、13、16、20、33、42

QYYEQ

Polyimide-F46 composite film and EPR insulated, lead sheathed,

galvanized steel tape interlocked armoring, cable for submersible

oil pump

 

232

10、13、16、20、33、42

QYYEEY

Polyimide-F46 composite film and EPR insulated, EPR sheathed,

galvanized steel tape interlocked armoring, round cable for

submersible oil pump

 

204

10、13、16、20、33、42

QYJEQ

Polyimide-F46 composite film and EPR insulated, lead sheathed,

galvanized steel tape interlocked armoring, lead wire for

submersible oil pump

 

200

10、13、16、20、33


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:1.2 meters below the road can use pvc tube wear armor cable?
The former bv4 square copper wire is a single strand of hard copper wire, the latter BV4 square copper wire is multi-strand soft copper wire. Core (coredwire), with steel sheath for the outer tube filled with iron alloy powder to do core material, cross-section for the circular or rectangular line body. Also known as cored wire. It is used as a steel-making furnace outside the refining of the feed method to add refining agent and alloying agent. Can be directly added to the deep steel, the molten steel for deoxidation, desulfurization, degassing and non-metallic inclusions denatured treatment, to eliminate the aluminum deoxidized steel in the continuous casting steel | iron when the nozzle plugging the problem. As the deep addition of alloying elements in the molten steel, so the alloying element recovery rate is high and stable, the steel components can be fine-tuned to the best range. The reproducibility of the results is good.
Q:Pvc threading tube packaging film how to do attractive, on the grade it? Thank you great god
If the upstairs said that the number of troughs in China. I am doing strong electricity. It is entirely possible.
Q:Yjv22 cable laying pipe when the casing with plastic or steel pipe
In the air defense regulations, the pipelines of the air defense zone need to be treated with the protective wing ring. The bridge frame is designed according to the cable laid in the bridge. The cable size and quantity determine the size and quantity of the casing. Increase the standby, air defense requirements casing with hot galvanized treatment, both sides of the exposed wall shall not be less than 100 mm, wing ring production can refer to rigid waterproof casing or flexible waterproof casing (explosion-proof). The general construction plans will have a clear sign, or should be presented to the Design Institute in the trial.
Q:TV tiger when the set-top box when tv / ay look for a look on the platform
. the first two said two cables, KW is KVV that PVC insulated jacket control cable. . the control cable for industrial and mining enterprises, energy and transportation sector, for the exchange rated voltage 450/750 volts below the control, protection lines and other occasions, the use of PVC insulated, PVC sheathed control cable. . the performance difference: the power cable in the main line of power systems used to transmit and distribute high-power power, control cable from the power system distribution point of electricity directly to a variety of electrical equipment, power equipment, power lines. The rated voltage of the power cable is generally 0.6 / 1kV and above, the control cable is mainly 450 / 750V. The same specifications of the power cable and control cable in the production, the power cable insulation and sheath thickness than the control cable thick.
Q:What recycled rubber is suitable for the production of wire and cable?
Need to choose according to specific circumstances. The main difference between single and multi-core is the flexibility of the wire. In fact the two do not exist which good question, but the use of the environment is not the same. Home decoration: First, the lighting line, can be used 1.5 single strand copper wire. . 2P (inclusive) or more of the air-conditioning, that is, hot water heater, Yuba must use 4 square double strand copper wire; Third, the wall buried the best choice for single wire copper wire, you can choose according to the need for 4 square Mm, 2.5 square millimeters, 1.5 square millimeters and other specifications (usually 2.5 square millimeters with the most). Fourth, the remaining lines, are using ordinary 2.5 pairs of copper wire can be.
Q:Why my home analog TV connected to the digital TV set-top box after the screen is black and white
Cabling in the integrated wiring system according to the network topology diagram to configure how to connect, no network topology is unable to give the correct connection.
Q:What does the cable (YJV-5 * 6) mean?
Full name: cable ZR-YJV22-4 * 16MM2ZR: flame retardant ----- YJV22: copper conductor cross-linked polyethylene insulated PVC sheathed double steel belt wrapped armored power cable --- 4 * 16MM2: 4 core, each core 16 square millimeters.
Q:How to identify the quality of the lock of the hotel lock?
Ming assembly line tube card 1 meter a, turn from the wall 10 a square, far away, the tube will fall down.
Q:Ceiling on the wire after the tube is the tube on how to fix it on the ceiling?
General telephone lines, lighting control lines or wire diameter in the 1.5 square millimeters of small lines with 4 points. More than the aforementioned line will use the 6 points.
Q:With the patch panel how to deal with the line corresponding to the crystal line of the line order is what
The The The The The The The ; The fifth 5 pairs are purple blue, purple orange The The The The The The Purple gray The last 5 to see the next line marked on both sides of the corresponding on the line

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range