• ESP cable jacket includes NBR,compound of the neoprene and PVC, EPR, fluoroplastics System 1
ESP cable jacket includes NBR,compound of the neoprene and PVC, EPR, fluoroplastics

ESP cable jacket includes NBR,compound of the neoprene and PVC, EPR, fluoroplastics

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Brief introduction

 

The product manufactured by us has the characteristics of advanced technology,reliable quality. The main manufacturing equipment is included the ROYLE Ф90 plastic extruder, the rubber continuous vulcanizing process, the interlocked armoring machine made by CEECO, Canada, the continuous sintering process imported from GRILLER, Austria, the Nokia cross-linked cable process, the advanced continuous annealing process and tinned process, etc. Now, the cable and coil end lead wire for submersible oil pump or pump unit can be produced, with different types and specifications, the cross-section of conductor is 42mm2 and below. The well temperature is from 50℃ to 180℃, the max. continuous working temperature of conductor is 204℃. The insulation material that can be used is as below: PP, EPR, polyimide-F46, fluoroplastics, XLPE, etc. The material of inner jacket includes NBR,compound of the neoprene and PVC, EPR, fluoroplastics, lea, etc. The outer sheath material is as the galvanized steel tape, stainless steel tape, etc. All kinds of cables for

submersible oil pump can be developed according to the customer’s requirements.

 

Brief type and size

 

Cable type

Description

Max working temperature℃

Product range (cross section)  mm2

QYPN

PP insulated and NBR sheathed, galvanized steel tape interlocked

armoring, cable for submersible oil pump

 

96

10、13、16、20、33、42

QYPNY

PP insulated and NBR sheathed, galvanized steel tape interlocked

armoring, round cable for submersible oil pump

 

96

10、13、16、20、33、42

QYEN

EPR insulated and NBR sheathed, galvanized steel tape interlocked

armoring, cable for submersible oil pump

 

140

10、13、16、20、33、42

QYENY

EPR insulated and NBR sheathed, galvanized steel tape interlocked

armoring, round cable for submersible oil pump

140

10、13、16、20、33、42

QYEE

EPR insulated and sheathed, galvanized steel tape interlocked

armoring, cable for submersible oil pump

 

175

10、13、16、20、33、42

QYEEY

EPR insulated and sheathed, galvanized steel tape interlocked

armoring, round cable for submersible oil pump

 

175

10、13、16、20、33、42

QYEQ

EPR insulated and lead sheathed, galvanized steel tape interlocked

armoring, cable for submersible oil pump

 

204

10、13、16、20、33、42

QYYEQ

Polyimide-F46 composite film and EPR insulated, lead sheathed,

galvanized steel tape interlocked armoring, cable for submersible

oil pump

 

232

10、13、16、20、33、42

QYYEEY

Polyimide-F46 composite film and EPR insulated, EPR sheathed,

galvanized steel tape interlocked armoring, round cable for

submersible oil pump

 

204

10、13、16、20、33、42

QYJEQ

Polyimide-F46 composite film and EPR insulated, lead sheathed,

galvanized steel tape interlocked armoring, lead wire for

submersible oil pump

 

200

10、13、16、20、33


Q:I am planning on buying new power and ground cables for my car system. How much would it cost for 4gauge wire? and how much would a fuse for that cost? -my system is about 1000w
you could go to walmart and get a kit for about $50
Q:I'm only asking this on here out of interest, this is not homework. I want to know how to calculate exact distances between to poles connected at the top by a cable. The length or height of the objects are not important to me, but if you must use an example please do so. So I want to know what formulas to use, what variables in those formulas mean, and how the slope of the cable will affect the distance. For example, if two poles have a distance between them of 0, and the cable extends 100, it would not mean that the drop of the cable (called a catenary?) would be 50, (it's misleading because you would think that since the distance between the two poles is 0, the cable would drop 50 and rise 50. But this is not taking into account the slope it has to take at the bottom of the catenary. It must lose some drop (perhaps to 48 or 49) in order to bend and rise back up...I want this out of my head, it's bugging me that I can't figure it out.
No sign can commute faster than the fee of sunshine (neglecting tachyons, that have in no way been pronounced interior the genuine international, yet in concept can in no way slow all the way down to or commute under the fee of sunshine). The ropes and poles could flex because of the fact the sign traveled alongside them. because of the fact that they'd not flow right this moment, the sign could commute at a speed nicely under c. right that's a version on the pole concept. think you have 2 very long poles crossed at an attitude. The poles are rotating from their crossed orientation to alter into extra parallel. the factor P the place the poles bypass will commute down the poles as they attitude parallel, shifting faster and faster. Can the action of P exceed the fee of sunshine? particular it could! P would not have any actual manifestation and for this reason no mass; for this reason its action isn't constrained with the aid of relativity. in spite of the undeniable fact that, if P did have mass -- as an occasion, if there became a hoop around the crossing factor -- then the poles could be compelled to flex because of the fact the relativistically increasing mass drew further and further ability from them. * To Michael under: Einstein's particular concept of Relativity states that it could consume an limitless quantity of ability to strengthen up any particle with mass to the fee of sunshine. So that is impossible to strengthen up even an electron to the fee of sunshine, regardless of the certainty that scientists can get very very close now. Photons have not have been given any mass so as that they commute on the fee of sunshine and easily on the fee of sunshine (and is the reason why every person measures an identical fee for c). Tachyons have an 'imaginary' mass (a dissimilar of the sq. root of -a million) and so as that they can't commute as slow or slower than mild... merely faster!
Q:how do i run my power cable wire through the firewall, to my battery in my 1995 Monte carlo?please help?
Now djp answered this question correctly but after drilling the hole makes sure you put a grommet in the hole to prevent a short
Q:I have an internal SATA drive that im looking to access through my laptops eSata (external SATA) port. Im buying the cable required for this but im curious after I make the connection is there a separate cable i need to provide power to the hardrive?Or does the sata to esata cable provide power to the internal drive
An okorder / Yes you do need a separate power cable for any SATA devices, but that enclosure uses a small controller board to make a single cable design possible.
Q:i am hooking up my system tomorow and im really not sure where to drill a hole in the firewall to run my 4 AWG cable any suggestions any pictures would be helpful thanks!
Check first for any factory made holes that are not in use or have extra space to be used. If you are explorer is anything like my Taurus I would say somewhere near where your steering wheel connects to the firewall. But it will be kinda risky around that area since you would have to be careful for your power steering.
Q:How do I get it not to do that? Its really annoying. Whenever I remove the charger cable , the screen gets really dark. It seems like an actual function and not a defect, but is their a way to toggle it on and off?
normal, although you can chage some of the settings under control panel as well as using the function key and raise/lower the brightness
Q:I found some cable online that I can use, but haven't had any experience with any of this.
I do not use anything but RG6 in my home, even for short lengths. If you want to try and can easily back it out and use RG6 if it doesn't work, then go for it. Otherwise, why risk it?
Q:I blew 2 fuses in my amp in my car, i have replaced them both, one was a 30amp and the other a 20. The 30 amp was an inline fuse from the battery to the amp and the 20 amp was a standard 20 amp fuse in the amp. As i said i replaced both fuses and try the amp again and it wouldnt go. There is a LED light on the top just lighting up a logo, when i attatch the power from the battery the light goes off and when i disconnect it the light comes on. When i dissconect the power the red light for diagnose comes on.
This sounds like a wiring problem i reccomend you completly inspect all wiring to your amp if looks fine then use a test light and test all the wiring if all passes then your problem is within the amp itself. test the remote wire with stereo to car on if wired that way.
Q:Hey.I just took out the power cable on my ps3, but then my light was gone in the same moment?How could that be :-D?
Bad wiring in the house? Sounds at least like a situation like that. Not uncommon in buildings of certain times.. older types of wiring used. And worse not ready for todays amount of electronics. So yeah check the wiring. In between time buy a few extension boxes, you know the type with more then 1 electronic socket. But most important a switch. That way you can switch it off and that way such discharges won't happen any more.
Q:on the end of the cable that connects to the laptop not the power outlet
That cylinder is called a choke. The purpose of the item is to deflect electrical interferences from the outside sources...like telephones, 2-way radios, ect. It also works as a shield for the brick or power converter that your laptop uses. It also puts out signals that could interfere in other devices.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products