Electrically Fused Magnesia Product

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Electrically fused magnesia is made by smelting finely sorted special grade-A raw magnesite in an electric arc furnace. Its features are high purity, big crystalline size, dense structure, good corrosion resistance, and thermal shock resistance.

Index

Chemical Composition /%

Grain/mm

Brand

MgO(≥)

SiO2(≤)

CaO(≤)

B.Dg/cm3(≥)

0-10

0-50

0-100

DMS-98

98

0.6

1.2

3.50

DMS-97.5

97.5

1.0

1.4

3.45

DMS-97

97

1.5

1.5

3.45

DMS-96

96

2.2

2.0

3.45

It is produced by the melting and cooling of magnesite in electric arc furnace.This product has the characteristic of tough and big crystal grain,good chemical stability,strong slag resistance and high strength and also high temperature.It is the main material for the producs of magnesium limestone and magnesia carbon refractory.the products are mainly used in large checker chamber of float glass stove,electric are furnace,industry kiln and insulant of householdappoliances etc.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:what's the varieties of thermal insulation material with A level fire rating?
Inorganic thermal insulation material can do it, such as glass wool,rock wool,foam glass,etc. phenolic foam materials in organic foam material is special. phenolic foam not only has good thermal insulation properties but also can be composited with steel plate and other materials, A class thermal insulation materials that reach A class combustion performance include: rock (mine) wool, foam glass, EVB, etc. thermal insulation materials with A class combustion performance mainly include: phenolic aldehyde,gelatine powder polyphenyl granule, etc. thermal insulation material of fire barrier zone can use rock (mine) wool, foam glass, EVB and other materials with A class combustion performance.
Q:What's the classification of flameproof glass, the refractory time of fireproofing glass.
According to different manufacturing technique, thermal insulation fire-resistant glass can be divided into grouting fireproof glass and composite fireproofing glass. Grouting fireproof glass has good thermal insulation performance, composite fireproofing glass has good fireproof performance.
Q:What's the organzational structure of refractory material?
Ingredients (harmful); phase composition. The main components of refractory material include chemical composition and phase composition. The addtional components include main crystal phase, matrix, crystal phase, chemical composition
Q:The structure of refractory material
Q:What are fire resistant level standards of class A fire resistant door?
Executive standard: GB12955-2008 Fire Door. Fire resistant level: Class A: 1.5h, B:1.0 h, C: 0.5 h. Thickness of door leaf: Class A: 50mm, B 45mm, C 40mm. Doorframe Specification: Class A, B, C. Door leaf form: Single open, double open, single open with glass, double open with glass, single open with glass and bright, double open with glass and bright, with a bright picture, Zimu glass Zimu glass with light. Doorframe Specification: Class A, B, Door leaf form: Single open, double open, single open with glass, double open with glass, single open with glass and brightness, double open with glass and brightness, double open with a lager door leaf and a smaller door leaf, double open with a lager door leaf and a smaller door leaf with glass, double open with a lager door leaf and a smaller door leaf with glass and brightness. Standard sizes: In line with GB5824-86 Hole Size of Building Doors and Windows."
Q:Who knows how to divide the building fire grade and fire resistance grade?
I hope to help you building fireproof rank division is one of the most basic measure in building fire safety technical measures, Building's fireproof rank is divided into class one, two, three, four according to China's architectural design specification. Fire-resistant capability of the highest level is the strongest; Fire resistance of four level of the weakest. The fire resistance level of a building depends on the combustion performance and fire resistance of the building components that comprise the building. The so-called building component refers to a series of basic components, such as wall, foundation, beam, column, floor, stair, ceiling and so on.
Q:What's the fire endurance of hollow brick?
This question is really very simple. It is better no to exceed 1050℃, or it will be easily burnt. I think 980 ℃ is ok in reality. It depends on how thick your wall is because fire endurance of hollow brick is related to wall thickness. 24 wall can generally endure for 3 hours or more.
Q:What is the limit of fireproof rolling shutter?
Fire proof door can be divided into Serie A, B and C in terms of fire endurance limit, fire resisting limit are not should be less than 1.20h, 0.90h and 0.60h. Set firewall has difficult sites can use fire shutter fire partition separating, when the back fire surface temperature rise refractory limit determination conditions of fire shutter, the fire resistant limit not less than 3H; when employed does not include back fire surface temperature rise do fireproof limit determination conditions of fireproof rolling curtain, on both sides of the shutter should be set up a separate closed type automatic water spraying system protection, sprinkler system continuation of time should not be less than three hours.
Q:What is fireproofing material? Are fireproof materials the same thing with thermal insulation materials and refractories?
The refractory material is capable of withstanding high temperature burning, while fireproofing material is to prevent burning. They are different from each other
Q:What's the fire endurance of fire windows?
Fire endurance of fire doors and fire windows stipulated by the fire prevention norm: Fire endurance of A class fire door or fire window is 1.2h rather than 1.5h, and fire endurance of B class fire door or fire window is 0.9h rather than 1.0h. Fire prevention code doesn't explicitly state that the fire door has thermal insulation function, so it can definitely be interpreted that the fire door only has fire integrity. For the fire door without heat-shielding performance, at certain distance from the unexposed surface, it has strong thermal radiation and is easy to hurt people. For the A class thermal insulating fire door, its fire integrity is 0.1h shorter than that of the corresponding fire door stipulated in the specification, but its heat-shielding performance and integrality is improved. All in all, compared with the specification that the fire integrity of the A class fire door should be 0.6h, it has much more improved its performance.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range