electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Characteristic:

1.Magnetic Driver design without shaft seal.Sealing up completely, There is no leakage of chemical liquid . It's good for the environment,

2.It's apply to Chemical liquid(acid or alkali) transportation.

3.Pump applicable temperature:GFRPP-75 °C , CPVC-80°C,PVDF-90°C. Pump material decided by chemical liquid properties.

electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Details:


1. Model :MP


2.Pump Material:F-GFRPP  A-CPVC  P-CFRPVDF  E-CFRETFE


3.Power:203-45W  204-65W  255-90W  257-150W  258-260W


4.Connection Type of inlet/outlet :S-screw type   H- Straight pipe type


5.Pump spindle:C-CERAMIC  T-TITANIUM(Ti)  S-SIC


6.Rubber Material :E-EPDM  V-VITON


7.Frequency :5-50Hz  6-60Hz

8.Voltage :V11-110V/220V/1ø  V38-220V/380V/3 ø


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Brief description of centrifugal pump on / off operation
(3) check whether the turning rotor is easy and flexible, check the pump body is clang or friction sound.(4) the protective cover is installed, and the shield contact.(5) clean the pump frame and do a good job of sanitation.(6) open the inlet valve, make the liquid full of pump body, open the vent valve, clean the air and close it. If the hot oil pump, it is not allowed to open the air valve exhaust, to prevent hot oil channeling spontaneous combustion, if there is a dedicated vent pipes and tanks, you can vent the pipe line air and cold oil.(7) the hot oil pump should be preheated slowly before starting. Especially in winter, the pump body and the pipe should be preheated at the same time, so that the temperature difference between the pump body and the conveying medium is below 50 centigrade.(8) the oil must be sufficiently dehydrated before being introduced into the oil pump.
Q:What does electromechanical vector pump mean?
Commercial buildings: hotels, office buildings, department stores, large saunas, etc.Irrigation: such as parks, playgrounds, orchards, farms, etc.Manufacturing: such as manufacturing, washing equipment, food industry, factories and so on
Q:Advantages and disadvantages of centrifugal pumps?
Centrifugal pump; advantages and disadvantages:(1) advantages:The structure of the pump is simple and compact, and the centrifugal pump has small area, light weight, little material consumption and high cost for the foundation. Therefore, the cost of manufacturing and installation is less.For high speed operation, the 2 pole or 4 pole motor can be directly connected. The drive structure is simple and easy to install.
Q:Why does the centrifugal pump start and close first when the outlet valve is closed?
The operation rules of centrifugal pump strictly required to close the outlet valve before the shutdown, boot and then slowly open the outlet valve, regulating pipeline pressure and current range. The reason is: the centrifugal pump in the startup process in order to avoid large starting current caused by electrical faults, such as circuit breaker tripping,
Q:Troubleshooting of diaphragm pump
In the application of the pump, these conditions are likely to encounter. Each situation can be divided into several possible reasons. This guide lists the causes of failures and gives appropriate corrective maintenance measures. The meaning of all the specific terms in the guide is listed later.Air valves - copper or stainless steel valves are bolted to the center of the pump by four bolts.The piston aluminum cylinder is enclosed in the air valve to control the gas flow.Cavitation - because the pump inlet for the amount of fluid to reduce or lack, the pump discharge is less than the amount of quantitative. In fact, the fluid chamber is full of fluid before it is discharged.Static pressure drop - the inlet pressure from the pump centerline to the free point - the inlet is measured in pounds, including the specific gravity and velocity of the fluid.
Q:How to select hydraulic pump?
Select the hydraulic pump from the following considerations:1. hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
Q:Rules for operation of centrifugal pumps
Operating rules:1, before starting to check whether the water pump foot loose, coupling shield, and motor fan blade cover is intact, in order to ensure the safety of equipment and personal safety.2. Check whether the inlet valve is open and open as fully as possible. Is the outlet valve closed, open the bleeder valve, exhaust until there is no air, and close the bleeder valve. At the end of the valve to the pipeline in the pump cavity filled with water.
Q:What is the working pressure of the hydraulic pump in the hydraulic transmission system?
Generally speaking, for the fixed size, not limited equipment, the pressure can be selected lower, walking machinery heavy equipment pressure should be selected higher.If the load is selected, the working pressure is as follows:Load <5kN, working pressure <0.8~1MPa;Load 5~10kN, working pressure 1.5~2MPa;Load 10~20kN, working pressure 2.5~3MPa;Load 20~30kN, working pressure 3~4MPa;Load 30~50kN, working pressure 4~5MPa;Load 50kN, working pressure =5MPa;For example, the system work pressure of various machines is as follows:Grinder 0.8~2MPaModular machine tool 3~5MPaLongmen planer 2~8MPaBroaching machine 8~10MPa agricultural machinery, small construction machinery, construction machinery, hydraulic drilling machine 10~18MPa hydraulic machine, large and medium-sized excavators, heavy machinery, lifting transportation machinery 20~32MPa.
Q:What is the dry running protector of screw pump? What's the principle and function? Thank you
Principles are generally temperature sensing, such as: when the screw pump by air, the stator and rotor will be heated due to friction,
Q:The main factors affecting the performance of centrifugal pumps
The low specific speed pump, on the other hand, is suitable for smaller flow and higher lift. When the pump outlet pipe diameter at the same time, if the two pumps flow similar, smaller than the speed of small head, shaft power consumption is also large. Generally speaking, the centrifugal pump with smaller revolutions than the impeller has a narrow outlet width and a large outer diameter, and the channel formed by the blade is narrow and long. If the ratio of revolutions is large, the impeller outlet is wide and the outer diameter is small, then the flow passage is short and wide.I hope my answer will be helpful to you. I hope to adopt it!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range