Product Description:

 

Feature:
1) Material: Steel
2) Finish: Zinc plasted
3) EMT conduit clamp is designed for use in channels to fit electrical conduits
4) Size: 1/2" up to 4" Electrical conduit,galvanized clamp,conduit clamp
5) According to UL standard

Applications:
Electrical conduit,galvanized clamp,conduit clamp
These conduit hangers are used in both wet and dry locations to support runs of rigid/IMC and EMT conduits from ceilings and walls.
EMT conduit clamp,Conduit pipe clamp,Electrical metal conduit clamp
Advantage:
Conduit hangers include a bolt and nut to make a speedy and economical installation. The zinc plated steel provides durability and corrosion protection.

Competitive Advantage:Electrical conduit,galvanized clamp,conduit clamp
+Quick Delivery: In 30 days for one 20ft container.
+Competitive Price 
+ Good Quality: ISO/UL certificate approval
+Best Service: fast delivery, strong package, good price, timely and effective communication
+Powerful Solution: fast and effective solution to problem

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Decoration doubt, what kind of wall can not open the horizontal groove?
Excretion training is the use of positive reinforcement, that is, a variety of food, toys, the best time to reward
Q:Apple 6 Charging Why always show this cable has not yet been certified
Motherboard and power supply problem, the best way is to try to USB2.0 ban on the use of USB1.1 but will be slower
Q:How to distinguish how many pairs of cable with a large heat shrink tubing
Yellow line is video, red and white are audio, you can only pick one!
Q:How much of the cable with the switch?
The switch is not selected according to the cable and is selected according to the current. The cable is determined by the size of the power (converted to current) and the distance from which the distance is far. The greater the power distance, the greater the cross-sectional area of the required cable. For example: 15KW motor selection cable current I = P / 1.732UcosΦ = 15 / 1.732 / 0.38 / 0.8 = 28A if it is close (within tens of meters), copper cable 6 square millimeters, aluminum cable 10 square millimeters. If it is in the distance (a few hundred meters), copper cable 10 square millimeters, aluminum cable 16 square millimeters. If it is long distance (close to kilometers), copper cable 16 square millimeters, aluminum cable 25 square millimeters. The switch is regardless of distance, completely based on the load current to choose, generally according to the load current of 1.5 times to 2 times to choose.
Q:7 kilowatts of electricity with what specifications of the wire
7 kilowatts of electricity with what specifications of the wire if it is single-phase 220V, then 7 kilowatts of current is 7000 × 220V = 31.8A, check the electrical manual 4 square copper wire interception is 33A, to meet the requirements.
Q:25 square copper cable how much money one meter?
3 plus 1 64.13 yuan, 3 plus 2 75 yuan, 4 plus 1 81.38 yuan contact to see my registration name
Q:How to solve the computer connected to the TV audio problem, how to set the computer and TV audio separation
If you want to ensure that the transmission medium does not cause the signal to cause attenuation and interference, fiber transmission or balanced cable transmission is the best solution. If you need fiber transmission, the cost is high because you need to buy digital fiber converters and digital audio decoders and related equipment, but this can be to the maximum extent to ensure the integrity of the signal and the smallest noise interference. If you want to use low-cost transmission can also be used directly to the cable transmission, but must use a balanced interface for transmission, and with 2-core shield or 3-core, 5-core shielded cable for transmission. This can also ensure the clarity of the signal to the maximum extent, but do not eat hungry thirsty 丨 Chicken check blood sausage is too long. No matter how good the cable will be attenuated, the size of the attenuation will directly affect the signal quality and signal integrity. So the transmission distance with the balance line can not be too far. More than two kinds of transmission methods than the existing single-line transmission is much better, if you are a fever-level players, I suggest you use fiber transmission. But if your power amplifier or your source signal to noise ratio is not high, I do not recommend you use fiber transmission, because even if the quality of fiber transmission no matter how good your source is not high, then it does not make sense The
Q:1000 kW 600 m cable to use much
Three-phase 380V, 1000 kilowatts load, the working current is about: 1899A. The total area of copper cable is not less than: 1200 mm2 copper cable. . the cable is usually a few or several groups of wires (at least two each) twisted from the rope-like cable, each group of wires are insulated from each other, and often around a center twisted, the entire outer package Highly insulated cover. Cable with internal power, external insulation characteristics. . the cable has power cables, control cables, compensation cables, shielded cables, high temperature cables, computer cables, signal cables, coaxial cables, fire cables, marine cables, mining cables, aluminum cables and so on. They are composed of single or multi-strand wire and insulation layer, used to connect the circuit, electrical appliances and so on.
Q:5 air conditioning can be used 4 square cable
Lengthened low voltage side, the line resistance increases, the voltage drop increases. Reduced load capacity. So that the router due to insufficient supply voltage and can not work properly. It is not allowed to use 9V power supply. Voltage is too high, the router part of the internal power supply increased power, heat increased, it is possible to burn the router. It is necessary to extend the power cord, I suggest you extend the power supply side (220V one end) safe and reliable. Increase the voltage to increase the supply current, in the electrical working voltage range (with the electrical work voltage range) is allowed, too low electrical appliances can not work properly. Too high there is the risk of burning appliances, according to your actual situation, marked 5V0.2A that the router works at rated voltage, so the way to improve the supply voltage is not applicable. So you can only improve the power supply power (that is, you say to increase the power supply current rather than voltage). With the reserve power, it will provide enough current at the rated voltage (the router as a resistor, from I = U / R, you can know the danger of increasing the voltage) need help please message
Q:What is the type of pipe that is marked as KBG pipe?
If no color distinction, 100 meters after you know which line of the fire line which line? The

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range