Electric Driven Horizontal Self Priming Pump

Ref Price:
$200.00 - 250.00 / set
Loading Port:
Shanghai
Payment Terms:
TT or LC
Min Order Qty:
1 set
Supply Capability:
1000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

                        Electric Driven Horizontal Self Priming Pump

1.Structure of Electric Driven Horizontal Self Priming Pump Description

The pump has the ability of simple structure, easy operation, smooth running, easy maintenance, high efficiency, long life, strong ability of self-absorption. No bottom valve needed to install in the pipeline, just to ensure that pump body filled with priming oil before work.

 

2.Main Features of Electric Driven Horizontal Self Priming Pump

Strong self-priming capacity 

convenient operation 

easy maintenance 

high efficiency 

3.Electric Driven Horizontal Self Priming Pump Images

Electric Driven Horizontal Self Priming Pump

4.Diesel Driven Self Priming Sewage Water Pump Specification

 

Material

 

Cast Iron, ADI, CD4MCU, 316 SS, Alloy 20, C276.

Diesel Driving

 

Water cooled or air cooled

Method of Connection

Self-priming pumps are available as basic units or may be flex-coupled, V-belt driven or engine mounted.

Inlet/Outlet

 

2''(50mm), 3''(75mm), 4''(100mm), 6''(150mm), 8''(200mm), 10''(250mm), 12''(300mm)

Impeller Diameter

 

158.74mm-457.2mm

Rotary Speed

 

550RPM-2150 RPM

Flow Rates

 

8m3/h-1275m3/h

Head

 

6m-63m

Horsepower

 

1HP-125HP

Solid Passing

 

20.63mm-76.2mm

5.FAQ

How to guarantee the quality of the products

We have established the international advanced quality management systemevery link from raw material to final product we have strict quality testWe resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance. Normally, We have 1 year warranty.

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Pump adapter joint net outside tube, what is the principle?
First, the working principle:Fire pump adapter is connected with the public security fire department fire engine or motor fire pump fire water transport through the fire pump adapter interface fire water supply pipeline to the buildings, the fire hydrant indoor get sufficient pressure to solve the problem of water shortage and other difficulties or because of fire water supply pipeline inside the building due to low water pressure caused by the fire fighting for high-rise building, indoor use and normal operation of fire pumps and intermittent water supply situation in. The installation types include floor type, underground type and wall type.A brief introduction to the two, pump adapter:When a fire occurs, the fire engine pump can quickly and conveniently through the interface and building the adapter in the fire fighting equipment is connected, and the water pressure, so the indoor fire equipment pressure with sufficient water to extinguish, different floors of fire, effectively solves the problem of building fires, fire fighting because of difficulties or indoor fire fighting equipment due to lack of adequate water pressure to the fire.
Q:What is the function of a submersible pump?
Submersible pump motor and pump is directly connected with the water pump body into the water to work, it is suitable for the extraction of groundwater from wells, can also be used in rivers, reservoirs, canals and other water projects: mainly used for irrigation and plateau in the drinking water, but also for the city, factories, railways, mining and construction site the use of water supply and drainage.Characteristics of submersible pumps for well1 、 motor, water pump, submerged operation, safe and reliable.2, the well pipe and pump water pipe without special requirements (i.e.: steel tube wells, tube wells, Doi ash can be used).3, installation, use and maintenance of convenient, simple, small footprint, do not need to build pumping stations.The structure is simple, and the raw materials are saved.4, submersible pump conditions are appropriate, properly managed, and has a direct relationship with the service life.
Q:Explore the flow of water pump production process is like?
The main flow of water pump (take centrifugal pump as an example):Technical determination of Drawing > raw material storage > mold preparation > casting moulding > machining > parts experiment > Assembly > performance experiment > painting packing > storage.Here are a few key steps:1) the technique determines the graphMainly the work of designers. Generally according to the parameters of the pump (flow, lift, cavitation, efficiency, etc.) to determine the specific speed of pumps, impeller form, impeller size, impeller material, pump body, pump shaft and so on. One of the most important thing is to draw the impeller woodenpatterns.2) die preparationThe mold is mainly composed of workers according to the water pump impeller woodenpatterns production model.3) casting moldingThe casting molding sand is made on the base of the mould.4) machiningWater pump parts processing, because it has hydraulic flow channel, in considering the positioning clamping standard, must find the correct flow channel of the correct position. Avoid assembly, resulting in water pressure chamber and impeller flow channel skew, dislocation, uneven gap, or even rub, affecting product quality. In order to ensure the accuracy of parts manufacturing, it is necessary to design the appropriate tooling, and reasonable arrangements for technological processes, control process factors.
Q:Why can't sprinkler system and hydrant system share water pump in fire fighting system?
Why not share mainly because the two impurities contained in the water system: fire hydrant system requirements of different impurities in the water spray system requirements loose, but more stringent requirements, therefore, the former can be welded steel pipe, the latter must use galvanized pipe, the purpose is to prevent rust plug flow indicator or end of the spray head.
Q:What is called soft start of water pump?
Close the outlet valve of the pump, open the inlet valve, and can ensure that the water pump "self filling" (the liquid level is higher than the pump inlet pipe under the condition of the water pump start procedure is: to start the motor, to the normal operation of the motor, slowly open the outlet valve, the current gradually increase. But in the unattended operation (valve), and automatically pump, and pipeline diameter and length (in the pipeline water quality will be great), such as the motor start fast, to quickly promote the quality of water (as the train will soon accelerate acceleration), will make the motor starting current is large, causing the motor to trip and the damage of mechanical and electrical. Soft start (soft starter added in the circuit) - that is, slow motor speed, can overcome the above situation.Stop the pump normal order is: close the outlet valve, then stop the motor, such as unmanned operation, the outlet valve is not closed, when the pump stops suddenly, the water inside the tubes (especially vertical pipe), water will quickly turn back, so when the check valve suddenly closed, the fast flowing water suddenly stop by the inertial impact that produces "water hammer" effect and damage of pipeline system, using the "soft stop" should, in the circuit is connected with the soft stop device.
Q:Pump frequent start will reduce the service life, I ask what kind of frequency is called frequent start?
How to define this frequently, this can only say, for example, the life of the switch is 60 thousand times, once every hour you move, it can be used for a long time, and that if you move one minute, it would not necessarily for long.Pumps frequently start the first self wear problems, as well as the impact on the pipe network, especially the soft connections.Water pump if the frequency of use or time, it is recommended to adopt: variable frequency constant pressure control.
Q:What are the conditions for the series and parallel connection of the pumps?
Water pumps in series require equal flow, and the latter should be able to withstand the pressure of two pumps and.The parallel pump requires the pump with equal lift head, and the outlet pipe in parallel shall be chosen according to the flow rate of two pumps.
Q:Ask the principle of fire truck and pump adapter
Fire trucks to bring their own water, when the water is insufficient, the municipal pipe network, water fast docking adapter or outdoor fire hydrant. These look at the specific conditions of the scene, usually take more outdoor fire hydrant, because the outdoor fire hydrant connecting the municipal pipe network, fire pool and other water sources, you can guarantee the reliability of water supply.
Q:What are the brands of air conditioning pumps?
Many manufacturers have air-conditioning pumps, imported, domestic, import prices are more expensive. There are a lot of famous pump manufacturers in china. Wide one pump is very good.
Q:How many lift pumps should be used for 100 meters tall buildings?
35m lift around. HVAC pump lift is generally between 5~50m, the selection of the head is mainly to see the difference between water pressure. As head of 35m as an example, if the inlet height of 60m, so the theory of height =60+35=95m, if all pipe closed air conditioning water system, and resistance of the equipment for water is equal to the pressure difference is equal to the pump head to choose your height, and out of the water is the same, the resistance loss of lift all into the water. The calculated resistance loss is needed to pump lift. The resistance component (1) chiller resistance at 60-100kpa (2) water collector resistance in 120-200kpa (3) 20-50kpa (4) air terminal equipment body resistance is generally not less than 40kpa so 100m building the resistance calculation of estimated value = (1) 80kp+ (2) chiller resistance pipe, the collector resistance (140kpa+ 3) air terminal equipment 40kpa+ (4) body resistance 50kp=310kpa safety factor of 10% 320x1.1=341kpa H= P/ (head of pressure water density * acceleration of gravity g =352000/ (10m) X9.8 =34.8m fand) so we head for 35 meters

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range