Ductile Iron flanged Butterfly valve DN1000

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
200 set
Supply Capability:
10000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

SizeDN40mm-DN1400mm
Design StandardAPI 609
End flangeEN1092 , ANSI 125/150# , DIN2501
Face to faceEN 558-1, BS5155 , ISO 5752
Top flangeISO 5211
BodyDuctile iron,Stainless steel,WCB
DiscDuctile iron,CF8,CF8M,C95400,C95500
StemSS416,SS420,SS431,SS316
SeatNBR, EPDM, WRAS-EPDM
Suitale mediumSewage, Sea water, Air, Foodstuff and Oil

 

1) Sizes:

 

     DN40mm-DN1400mm
2) Materials:
     a) Body: CI(cast iron ,GG25 )   /   DI (ductile iron ,GGG40)

     b) Disc:  DI / CF8 / CF8M / C95400 
     c) Seat:  EPDM / NBR / TEFLON / VITON

 

3) Features:

 

    a)Cast hole. Flange connection meet ANSI 125/150#    DIN PN10/16     BS4504 PN10/16 in the meanwhile.

 

    b)Soft seat. Replaceable.Increase of service life.

 

    c)Double half shaft without pin.

 

    d) Square and short neck. Easy to stick scutcheon and cost saving.

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Check valve; flexible joint `; installation order of electric butterfly valve
It is better to make an elastic hanger.In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order, custom order rubber head, check valve, electric butterfly valve.
Q:Three eccentric hard sealing butterfly valve, why not fit in the end of the pipe?
Three eccentric hard seal butterfly valve quality standards, up to zero leakage, but you mean the end of the direct discharge?If so, that's OK. First you have to calculate how much the pipe fluid pressure is.For example, the pipe fluid pressure is highest and the pressure is 1.6MPa (16 kg)Should choose three eccentric hard seal butterfly valve should be pressure 1.6MPa (16 kg)If you worry, optional 2.5MPa (25 kg) will not leak!Answer: three eccentric hard sealing butterfly valve can be installed at the end of the pipe
Q:How can the flange butterfly valve be installed on the pipe?
Outlet pipe configuration.If in the pipeline, the valve in order to do not bear the direction of the force and bending moment, it is best to set the valve at the exit side of the expansion joint. Valve opening and closing valve water pressure should not be borne by the foot, but through the valve flange, by the pipeline to bear as well.Butterfly valve structure is generally shorter length, and its butterfly plate will be extended to adjacent pipes or other parts, so be careful not to collide with other parts and interference. And to prevent the error matching pipe diameter greater than C and collide with the butterfly plate.Butterfly valve as a regulator, just adjust the flow and pressure. The valve is regulated by loss of pressure.
Q:How big is the butterfly valve with a diameter of 80?
Generally speaking, especially small caliber, the butterfly valve will not use the variable diameter. Therefore, the butterfly valve DN and pound class selection, according to the field pipeline flange DN and pound level.So, in a strict sense, the caliber of the butterfly valve and the diameter of the pipe have not much relationship.Specific to your pipe diameter, there are questions: 80 diameter refers to the outer diameter or inside diameter? Yes, there is no flange on the site. Do you need a pair of flanges to be supplied?
Q:I want to what is better a metal valve or tissue valve replacement for someone who is in their 30's?
Do you want to have kids or have more kids? This is going to be the biggest question you have to answer. The tissue valve will require no treatment after the replacement, other than another replacement in 10-15 years or whenever the valve starts to fail. The mechanical valve will most likely last the rest of your life, but will require the use of anticoagulants that would make any future pregnancy extremely risky. As to the sound many patients complain about hearing the valve clicking in times when it is very silent (dead of night etc.) Most find that keeping a Radio or tv on at a low level solves the problem, Id say in my experience about 50% of patients complain about hearing the clicking. The other issue is that using tissue valves, it is a slightly riskier operation every time you re-open someones chest, due to scar tissue formation. So instead of say 1-3% risk it might be 5% if the person is young and healthy. This is important since the tissue valve will only last 10 maybe 15 years. The atrial thrombus complicates matters, however which valve are they replacing? It might be possible to remove the thrombus at the same time as doing the valve. If not, mo matter what you will be taking warfarin, so the vavle choice really will not matter that much.
Q:What does "C" in D971F-16C DN450 RF mean for electric butterfly valves?
C represents the valve body and the material is cast steel;D stands for butterfly valve; 9 stands for electric; 7 stands for clip type; 1 represents middle line butterfly valve; 16 stands for nominal pressure 1.6Mpa; RF stands for flange joint; in the form of protruding surface.
Q:How can you tell the difference between a functional valve murmur and a non-functioning valve murmur?
mechanical okorder.com/
Q:Butterfly valve, two-way pressure and one-way pressure what is the difference?
The positive pressure and the reverse pressure, the pressure when the medium returns
Q:Butterfly valve is generally used in what position?
Butterfly valve used in furnace, coal gas, natural gas, liquefied petroleum gas, city gas, hot and cold air, environmental protection, chemical smelting and power building water supply and drainage engineering system in conveying a variety of corrosive and non corrosive media pipeline, used to adjust and cut off the media flow. It can also be used for switch control of low pressure pipeline medium.
Q:What's the difference between a clip type turbine butterfly valve and a flanged turbine butterfly valve?
For clip butterfly valves, there are no flanges at the ends of the butterfly valve. There are only a few guide bolts. The valve is connected with the end flange with a set of bolts / nuts.In contrast, the demolition to facilitate some of the lower cost of the valve, but the drawback is that a sealing surface problems, the two sealing surfaces have to be taken apart.Flange butterfly valve at both ends of the flange, and pipe flange connection. The seal is relatively more reliable, but the valve is of relatively high cost.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range