DS multistage split case pump

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

DS multistage split case pump, is a new generation of products combined the foreign technology and developed by our company after many years of research. It is the alternative to traditional section multistage pump. The fluid of DS pump is clean water, liquids containing a small amount of solid particles and corrosive liquid. It is mainly used for building high-rise water supply, industrial boilers, fire fighting, mine drainage, chemical, and a variety of industrial water systems.

The technical parameter of type XS pump:

Pump outlet diameter Dn: 80-1400mm

Capacity Q: 100-1000³/h

Head H:160-320m

Temperature T:-20℃-150℃

Solid parameter≤80mg/L

Working pressure≤4Mpa

Technical advantage

With two-stage impellers back to back in form, the axial force is balanced automatically. Canceled the necessary balance disc of the multistage pump, the reliability of pump is greatly increased and the trouble rate of the pump is reduced. It especially adapts to the application of the pump speed changes and the concentrated liquid’s viscosity.

Being short bearing span, it increases the rigidity of the shaft. The pump runs more smoothly and quietly. It especially adapts to the quiet situations.

Excellent hydraulic model, pump efficiency is higher than the multi-stage pumps with the same parameters, more energy saving and better environmental protection.

With the structure of the horizontal split case and suction inlet & outlet located in the lower part of the pump case, the pump is convenient to be operated, no need to remove the motor and pipe when maintenance. Therefore, it reduces the maintenance time and cost.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to install, operate and maintain the pipeline booster pump?
Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
Q:What do you mean by the self coupling device on the pump?
Overview of GAK self coupling device:The utility model relates to a GAK self coupling device, which is an automatic butt joint between a water outlet flange of a submersible electric pump and a water outlet pipe system.In the above additional coupling flange and the water outlet pipe seat inlet flange with a pair of wedge card, under the additional coupling flange and the water outlet pipe seat inlet flange and a pair of wedge cards in a wedge seat below the outlet pipe inlet flange card is made of elastic steel plate is fixed on the lower side of the seat pipe inlet flange. When the submersible pump water falling from above, Kaxianka additional coupling flange at the top of the wedge wedge and seat card outlet pipe above the inlet flange together, in the role of the dignity of the pump and submersible inclined wedge clamp, two flange will be put together in a pair of wedge under additional coupling flange and the water outlet pipe seat inlet flange the card will be in the elastic plate under the action of automatic card together. The utility model can solve the problem that a large amount of water leakage between the two flanges of the coupling is saved when the automatic installation and disassembly of the electric submersible pump is convenient, thereby saving energy.
Q:What does electromechanical vector pump mean?
Commercial buildings: hotels, office buildings, department stores, large saunas, etc.Irrigation: such as parks, playgrounds, orchards, farms, etc.Manufacturing: such as manufacturing, washing equipment, food industry, factories and so on
Q:What flowmeter is installed after the pneumatic diaphragm pump?
Compressed air source, the general pneumatic diaphragm pump starting gas source for 0.1~0.2mpa,The maximum working pressure is 0.7~0.8mpa, so in this pressure range, you can use the air filter relief pressure valve gas pipe, adjusting for air pressure, when the pressure is bigger, diaphragm movement faster, so the greater the flow, and vice versa
Q:Why is the flow of the pump too small will occur cavitation phenomenon?
This is because the impeller of the centrifugal pump rotating speed under the drive of the prime mover, when the valve opening decreases, flow rate is too low, can not be taken away by the friction heat generated by the impeller and the liquid completely, make the temperature of the liquid inside the pump. Thus causing liquid vaporization, forming cavitation. Especially in the power plant, the boiler feed pump is more remarkable. Therefore, when throttling regulation, we should set up recirculation system, increase the output flow of the pump to prevent cavitation. When the feed water rate is reduced to 1/3 of the maximum flow rate, the recirculating gate shall be opened so that the flow of the feed pump will be increased properly to ensure that the liquid temperature in the feed pump does not rise.
Q:What's the submersible pump?What is a submersible pump, and what about it?
Deep well submersible pump is a fountain, drinking water transportation, irrigation, hot springs, high-rise transport facilities, etc., deep well submersible pump excellent performance, so widely used in various fields.
Q:What does centrifugal pump mean horizontally?
Centrifugal pump horizontal opening meaning: pump shell and pump body along the pump blade horizontal central line is divided into the upper and lower halves, so that the maintenance of pump leaves when the pump top cover can be separated from the pump and bearing as a whole. No need to remove the pipe.
Q:What are the parts of a pump? How do you classify it?I just want to know
The liquid ring pump: pumping air, the working medium is generally at room temperature water gas lift pump: simple structure of submersible sewage pump: a form of basic principle, performance parameters of centrifugal pump, with it the same. Underwater installation, sound, water cooling condition, screw pump: spiral lower invasion water medium variety formThere are too many kinds of pumps, such as submersible pumps for wells, centrifugal feed pumps, sewage pumps, etc. the submersible pumps are wet, oil immersed, etc.The water pump for automobiles is divided into oil lubrication and grease lubrication,
Q:What does "dual purpose" of water pump mean? Please expert advice
1, if the water pump in the process of a strong vibration, then must stop to check what is the cause, otherwise it will cause damage to the water pump.3, when the pump valve Water Leakage, some people will fill with dry soil to the water pump inlet pipe, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started to work, these dry soil will enter the pump, then it will damage the pump impeller and bearings, thus shortening the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that need to replace the new.
Q:How to select metering pump head?
When it comes to metering pump heads, the usual problem is when they measure acid, chlorine, fluoride, and hydrogen peroxide. Due to the difference in concentration and operating temperature, it is difficult to determine the specific pump head material.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range