Double Suction Horizontal Split Casing Centrifugal Pump

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
5000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

1. Single stage, double suction, split casing
2. High flow rate
3. Competitive price, long serivce life
4. Short delivery time

Overview

Horizontal split casing pump is the new generation of high performance single stage double suction centrifugal pump, mainly used for water plant, air conditioning, water recycling, heating systems, and high-rise building water supply, irrigation and drainage pumping stations, power plants, industrial water supply system, Fire systems, shipbuilding industry, and other places of fluid transmission is the full replacement of SH, S, SA, SLA, SAP type double suction pump.

Technological Advantages
1. Bearing spacing between both ends is short, pump running stable, low vibration noise, and can increases the speed of running properly, to adapt to a wider range of performance.
2. Inlet and outlet at the same line, so that the pipeline layout is simple and convenient, beautiful.
3. The rotation of the same rotor can be reversed, reducing the risk of damage caused by the water hammer.
4. Unique design of high temperature, use of intermediate support, thick body, sealed cooling, bearing lubrication, so that the pump can run up to 200 ºC occasions, especially for heating network requirements.
5. Pump can be vertical or horizontal installed according to using conditions, seal can be mechanical seal or packing seal.

Material of Flow Components
Pump casing made of gray cast iron, ductile iron or cast steel.
Impeller made of gray cast iron, silicon brass or stainless steel.
Spindle in stainless steel or high carbon steel.
Other materials can be used upon requirement.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The working principle of magnetic pump
Structure characteristics1. permanent magnetPermanent magnet operating temperature range is made of rare earth permanent magnet wide (-45 - 400 DEG C), high coercivity, magnetic anisotropy direction is very good, also won't happen in the same demagnetization phenomenon when is close, is a good source of the magnetic field.2. isolation sleeveIn the metal isolation, isolation sets in a sinusoidal alternating magnetic field, in a cross section perpendicular to the direction of magnetic field lines induced eddy current and converted into heat. Eddy current expression is:. The Pe - K constant; eddy current; rated speed of N - T - pump; magnetic drive torque; F - the pressure inside the sleeve; D sleeve diameter; a material resistivity; and the tensile strength. When the pump design is completed, N, T is the given conditions, to reduce eddy current only from F, D, and so on. Non metallic materials with high resistivity and high strength production isolation, in reducing the eddy current effect is very obvious.
Q:What is the difference between an air pump and a water pump?
The air pump (Q. B ng air pump), namely "air pump", a device for removing air or add air from the enclosed space from a closed space. The air pump is mainly divided into an electric air pump and a manual air pump. Electric air pump. An electric pump powered by electricity; produces air pressure by constantly compressing the air through electricity. Mainly used in pneumatic rubber, car inflatable, etc..
Q:How to adjust the flow of piston pump?
Changing the size of the current in the solenoid valve can change the angle of the tilting element, and then change the stroke length of the plunger in the pump cylinder, that is to say, to change the flow of the pump. An inclined angle is called a quantitative pump, and the angle of inclination can be changed, which is called a variable pump.
Q:Is the sewage pump the same as the mud pump?
The upstream return speed of the washing fluid is required to remove the cuttings and rock powder from the drill in a timely manner from the bottom of the hole and reliably carry it to the surface. Through drilling and extraction, mud can be obtained at the bottom.
Q:What are the constant pressure pumps?
Chlorine booster pumpThe pressure range of chlorine booster pump is large, and different pump can be used to obtain different pressure area. The input air pressure is adjusted and the output pressure is adjusted accordingly. High pressure can be reached, gas 90Mpa. Wide range of flow, for all types of pumps only 0.1Kg pressure can work smoothly, at this time to obtain the minimum flow, adjust the intake volume can be obtained after a different flow. Easy to control, from simple manual control to fully automatic control, can meet the requirements. Automatic restart, regardless of what causes the pressure drop in the pressure loop, will automatically restart to supplement leakage pressure and maintain constant loop pressure. Safe operation, gas driven, no arc and spark can be used in dangerous situations.
Q:How accurate is the metering pump?
The measuring accuracy of the stable metering pump is as follows:In a diaphragm metering pump, the reciprocating motion of the plunger is passed to the diaphragm through the hydraulic chamber between the plunger and the diaphragm. In order to maintain the normal movement of the diaphragm, the hydraulic chamber is required to keep the volume of the liquid in the space (usually using hydraulic oil) unchanged. In order to ensure that the volume of the formation of membrane movement is always equal to the stroke volume of the plunger pump, so as to maintain the stability of the flow, but in the actual operation of the pump, the plunger seal will inevitably cause leakage at the same time, there may be a gas into the hydraulic chamber
Q:What are the starting and stopping procedures for centrifugal pumps?
Operation method and operation procedure of self-priming centrifugal pumpClick number: 440 release time: 2011-7-24Centrifugal pump method, centrifugal pump operation steps, centrifugal pump use steps
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
If the fish tank is made of metal, the fish tank is grounded or connected to the zero line, and then the fire line is put into the water, then your fish will be electrocuted immediately. Go back to the submersible pump, submersible pump line and the zero line very close, even if the firing line and the zero line at the same time the leakage occurs, fish could not swim between the firing line and the zero line, so the tank submersible pump leakage will cause the following hazards: 1, electric shock. 2, submersible pump short circuit. 3, the submersible pump serious fever, resulting in water temperature tank.
Q:5 floor water pressure is too low, what kind of water pump is better?
Installed pump flow, lift did not meet the requirements, this will need to re type selection, calculation;
Q:What is the name of the day pump and ground pump? Specific introduction
People often say "day pump" actually refers to the boom pump, it also has many other name, such as pump, boom pump, concrete pump, concrete pump truck, these words are "day pump".Ground pump, in fact, refers to the pump drag pump. Therefore, to understand the difference between day pump and ground pump is to understand the difference between the boom pump and the tow pump

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range