DN230 Spectacle Plate for SANY Concrete Pump

Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
1 pc
Supply Capability:
1000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:


Product Description:

Product Name: DN230 Spectacle Plate for SANY Concrete Pump

1.        Specification


SizeDN200, DN230,DN260
Materialtungsten carbide, Q235B steel, Vautid-150 electrode imported from Germany
Carbide HRA> 86
Electrode HRC> 63
Typehardfaced, tungsten carbide and 7 shape tungsten carbide
Applicationmud pump, shotcrete,trailer and truck mounted concrete pump
Manufacturer with competitive price

Leading manufacturer for all kinds of brand concrete pump wear plate, technical date as below

TechnologyTechnical StandardService LifeHardness
Atmosphere sintering processSY5064-855 times more than similar traditional productHRC>70
Tensile StrengthFracture Toughness valuesYield Strength
>1000Mpa10 Mpa1/2>1000Mpa
Substrate/Matrix MaterialBending StrengthHigh Temprature ResistanceSurface Roughness
45#,40Cr, 1Cr13 steel1100-1300 Mpa700-800 centigrade degreeRa<0.1< td="">
Bond StrengthCorrosion ResistanceCompactness
>110Mpa>95%Gas Hole Ratio<0.01%< td="">


2.        Application

Spare parts for mud pump, shotcrete,trailer and truck mounted concrete pump

         3.  Package

Plastic bag and carton box, also according to your requirements


Q1: Why buy Materials & Equipment from OKorder.com?

A1: All products have its ISO certifications, adheres to the highest standards and a commitment to supply chain safety and customer satisfaction.

Q2: How do we guarantee the quality of our products?

A2: We have established an advanced quality management system which conducts strict quality tests at every step, from raw materials to the final product. At the same time, we provide extensive follow-up service assurances as required.

Q3: How soon can we receive the product after purchase?

A3: Within three days of placing an order, we will begin production. The specific shipping date is dependent upon international and government factors, but is typically 10 to 30 workdays.

Q4: If we can produce DN230 Spectacle Plate for SANY Concrete Pump according to customers request?

A4: Yes, we can produce DN230 Spectacle Plate for SANY Concrete Pump according to the difference country situations to make it suitable to the market and customers. We have very professional technical team to make the design.

Q5: How to make a quick resolution for after service?

A5: We have overseas branches all-around of world, If needed, the seller shall dispatch 2 engineers to the buyer's site for supervision of training. The buyer shall make available of necessary facilities &skilled personnel at site for training.





DN230 Spectacle Plate for SANY Concrete PumpDN230 Spectacle Plate for SANY Concrete Pump


DN230 Spectacle Plate for SANY Concrete PumpDN230 Spectacle Plate for SANY Concrete Pump


DN230 Spectacle Plate for SANY Concrete PumpDN230 Spectacle Plate for SANY Concrete Pump




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to maintain and repair the booster pump of pipeline pump?
Two 、 troubleshootingfaultReasonRemoval method1. water pump does not produce waterThe water injected into the water pump is not enough, the rotation direction is not right, and the impeller passage is blocked.Pump water into the pump, pass through the impeller runner, adjust the direction of rotation.2. pump flow is insufficientThe pump speed is too low, part of the blockage, the total lift pump is higher than the rated value, the damage to the impeller.Clean the water pump and pipe, replace the impeller, increase the pump shaft revolutions, adjust the outlet valve.3. lack of outlet pressureThere is air in the liquid, the speed is too low, the impeller is damaged and the outlet valve is open.Exclude liquid air, increase the pump speed, replace the impeller, adjust the small outlet valve.
Q:What are the reasons for sealing damage of centrifugal pumps?
Two, cavitation. Cavitation (mainly from a thermal centrifugal pump).Because the medium is hot water, the water temperature is too high to produce steam, the gas in the pipeline enters the pump cavity height, and the part of the gas can not be discharged, thus causing water shortage to run, the machine seal dry grinding is invalid, and the cavitation erosion device is not available.Process: replace the machine seal.
Q:How to select metering pump head?
The main index affecting the selection of the pump head is the composition of the medium to be transported and added, as well as the pressure and the temperature of the external environment
Q:What are the characteristics of a pipe shield pump?
Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
Q:Concrete pump 125 pipe wall thickness
Concrete pump diameter 125mm, pipe wall thickness is generally 4mm, also have 4.25mm, 4.5mm, 4.75mm, need to be in accordance with the rules of transport.
Q:What is the minimum continuous flow of a pump?
The minimum continuous steady flow can be obtained by test and, in general, the pump supplier will indicate(2) minimum continuous heat limited flow (.API) provides minimum continuous heat limit flow, which means the minimum continuous flow that the pump can maintain and that its operation is not impaired by the temperature rise of the liquid being pumpedMinimum continuous heat limited flow can be calculatedIn the formula, the Pe amount of the fixed axis power is.KW;P pump medium density, kg / m3;
Q:What are the starting and stopping procedures for centrifugal pumps?
Before using the centrifugal pump, the operation instructions of the centrifugal pump shall be read carefully and the specific operation procedures shall be understood so as to make proper use of the centrifugal pump products. The first step is the operation of centrifugal pump inlet valve of centrifugal pump centrifugal pump for all open cavity filled with liquid, close the outlet valve, start the motor, the motor speed is normal, can gradually open the outlet valve, to adjust to the desired condition. Pay attention to self suction centrifugal pump starts to open the exhaust valve, outlet valve should be opened quickly in the normal operation of the motor, to prevent air inlet pipe off caused by cavitation phenomenon produces centrifugal pump, centrifugal pump vibration phenomenon leads to noise of the smoke is not on the water.
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q:What is cavitation, centrifugal pump cavitation phenomenon how to solve?
First, what is cavitation?:When the centrifugal pump shell has air, it produces less centrifugal force because the density of the air is much smaller than the density of the liquid. Thus, suction pressure at the entrance to the top of the tank liquid level and pump is bad enough to the liquid storage tank into the pump, the centrifugal pump self suction capability, the centrifugal pump can not transport liquid, this phenomenon is called "cavitation".When a liquid drops at a certain temperature to the vapor pressure at that temperature, the liquid produces a bubble. The phenomenon of producing bubbles is called cavitation. When the cavitation bubbles, flow to the high pressure, the volume of reduced, so as to burst. This due to the pressure of rising bubbles disappear in the liquid in the phenomenon called cavitation bubble collapse.
Q:Hydraulic pump displacement refers to the pump shaft what?
Just as you carry a spoon to the water. How much water can you pump at once (every turn)? That's the displacement.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range