DIN Standard Single Stage End Suction Centrifugal Water Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

               DIN Standard Single Stage End Suction Centrifugal Water Pump

1.DIN Standard Single Stage End Suction Centrifugal Water Pump

End Suction Centrifugal Pump complies fully to the European Standard BS EN733 / DIN24255 of performance and dimensions. They are used for pumping clean water or liquids similar to water, achieving wide application on plants, mines, city water supplies, air-conditioning coolers, firefighting system and irrigation. Pumps of the same model have different performance levels basing on different diameter after impeller trimming. Overall the whole series, there are only four sizes of shaft and five of bearing housing. As long as their bearing housings are of the same size, different pumps can interchange chief parts such as shaft, shaft sleeve, shaft seal, impeller nut, etc.

End Suction Centrifugal Pump is also very easy to be installed and maintained. Back pull-out design, driven through flexible coupling, so that pump casing and motor can remain in position while other spare parts are removed.

2.Main Features of DIN Standard Single Stage End Suction Centrifugal Water Pump

very easy to be installed and maintained

Back pull-out design

•Driven through flexible coupling

•Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3.DIN Standard Single Stage End Suction Centrifugal Water Pump Specification

 

Material

Cast iron

Pump diameter

350-1600mm

Flow range

1~200L/s

Pressure range

0.2~2.25MPa

Motor power range

1.5~200kW

Inlet/outlet Diameter

DN50~DN200mm

 

Casing

Cast Iron Standard, Ductile Iron, Stainless Steel Optional

Impeller

Bronze Standard ,Cast Iron, Stainless Steel Optional

Shaft

ASTM420Standard,ASTM304,ASTM316,ASTM1045 Optional

Shaft Seal

Mechnical Seal, Gland Pakcing Optional

 

Flow rate

2-1100m3/h

Head

2-152m

Speed

1450 or 2900(50hz),1750 or 3500(60hz)

Working Pressure

1.6PMa or 2.0PMa

 

4.Picture of DIN Standard Single Stage End Suction Centrifugal Water Pump

DIN Standard Single Stage End Suction Centrifugal Water Pump

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.

 

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How many kilograms of water pump are there in the automatic washing machine on the market?
Longer service life. Automatic switch water pump, car wash automatically open and stop, easy to operate, not easy to bad, repair rate is low!!!
Q:Variable flow pumps are variable pumps
Yes. The variable pump is designed to change the flow rate
Q:Centrifugal pump flow, why can be adjusted through the outlet valve?
Centrifugal pump, and is a very common method of centrifugal pump, flow with the head (or pressure) increases, off a small valve resistance increases, the pump head should be increased, then the flow decreased, whereas open valve flow increase
Q:No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same
Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
Q:What is an industrial water pump?
The pump has the different uses, conveying different liquid medium, different flow rate, different lift range, therefore, its structure of course is not the same, the material is different, in general, can be divided into:1, urban water supply 2, sewage system 3, civil and construction systems 4, agricultural water conservancy system 5, power station system6. Chemical system 7, petroleum industry system 8, mine metallurgy system 9, light industry system 10, ship system
Q:How do vacuum pumps and pumps work together?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve.
Q:Fire pump and shower pump flow head selection, high resolution.
2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
Q:What are the starting and stopping procedures for centrifugal pumps?
Before using the centrifugal pump, the operation instructions of the centrifugal pump shall be read carefully and the specific operation procedures shall be understood so as to make proper use of the centrifugal pump products. The first step is the operation of centrifugal pump inlet valve of centrifugal pump centrifugal pump for all open cavity filled with liquid, close the outlet valve, start the motor, the motor speed is normal, can gradually open the outlet valve, to adjust to the desired condition. Pay attention to self suction centrifugal pump starts to open the exhaust valve, outlet valve should be opened quickly in the normal operation of the motor, to prevent air inlet pipe off caused by cavitation phenomenon produces centrifugal pump, centrifugal pump vibration phenomenon leads to noise of the smoke is not on the water.
Q:What is the working pressure of the hydraulic pump in the hydraulic transmission system?
The operating pressure of the hydraulic system depends mainly on the load. Generally speaking, the working pressure of the hydraulic system means the highest working pressure of the system. If the pressure is higher than the value of the equipment, the relief valve works to relieve pressure. The actual working pressure of the hydraulic system is determined by the load, which refers to the actual pressure of the hydraulic oil and can be read directly from the pressure gauge. The pressure increases with the increase of the load. You Li's balance can know: the thrust of the cylinder = the load, the thrust of the cylinder = the working pressure of the hydraulic oil, the working area of the cylinder, the working pressure = the load / the area of the cylinder.
Q:The distance from the pump button to the ground
A button is arranged on the surface of the fire hydrant button, and when the fire hydrant is started, the press button can be pressed directly, and the red starting indicator light of the fire hydrant button is on

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range