• Dimmable Led Driver 60 Watt System 1
Dimmable Led Driver 60 Watt

Dimmable Led Driver 60 Watt

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Piece pc
Supply Capability:
10000 Pieces per Day pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Features 

1.Advanced patent dimming technology

2.Suitable for leading edge or tailing edge dimmers

3.Short cicuirt and over current and over voltage protection

4.Recycle and no hazardous substance

5.Double isolation design for human safety

6.Conveniently connected terminals(screws)

7.Fireproof environmental protection PC plastic cover

8.3 years quality Warranty

 

Constant Current

Input Voltage(V/AC):110V&230V

Power(W):60W

Output Voltage(V/DC):45-74/84-140

Output Current(mA):700/350

PF:>0.95

Efficiency((%):>84%

Dielectric Strength(V/AC):3000

Size(mm):123*79*35

Operation Temperature:-30~45 degree

Storage Temperature:-40~70 degree

Thermal Dissipation:Nature

Relative Humidity:5~95%

Isolation Voltage:In/Out 3000VAC

Vibration:5-55hZ/2G,30Minutes

Life time:50000H,AT tc max

Constant Voltage

Input Voltage(V/AC):110V&230V

Power(W):60W

Output Voltage(V/DC):12/24

Output Current(mA):4000/2000

PF:>0.95

Efficiency((%):>82%

Dielectric Strength(V/AC):3000

Size(mm):123*79*35

Operation Temperature:-30~45 degree

Storage Temperature:-40~70 degree

Thermal Dissipation:Nature

Relative Humidity:5~95%

Isolation Voltage:In/Out 3000VAC

Vibration:5-55hZ/2G,30Minutes

Life time:50000H,AT tc max 

Q:Power and lighting transformers, lighting quality will be affected much?
The bulb adopts a luminous two stage tube combined lamp holder, and the calculation process is very complicated. The secondary voltage is different in different combinations. Because it is a direct current ignition, but also consider the efficiency of its rectifier, but the total power is unchanged.
Q:Is the substation separate from the power and illumination transformer?
There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
Q:Who knows how big transformers and lines the 36V transformer uses in lighting?
No matter how many volts the output / input voltage of the transformer is, the size and the amount of the core of the transformer, the wire diameter of the winding lead and the lead thickness must be determined by the transformer capacity. Example: input 220V, output 36V load is 36v/40w light bulb 6, so the primary needs 0.72, secondary use 1.81 diameter enameled wire winding system. The transformer capacity is about 250VA.
Q:Why should lighting transformers be used in factories and mines?
In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
Q:Does the lighting work properly? Doesn't that power equipment start voltage unstable?
The transformer that power supply company manages, it is to supply motive power and illumination generally, namely the lighting transformer that does not have special illumination to illuminate. Units of their own transformers, is generally the case. The utility model has the advantages that the transformer and other equipment can be fully utilized, the efficiency is high, and the external power supply circuit does not need to be divided into power transmission lines and lighting circuits, and is simple and orderly, and the cost is low. As for the price of electricity, it is usually negotiated a power and lighting each percentage of the electricity to calculate and receive.
Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
If you share a power line, you must calculate the current and select the appropriate wire to ensure normal pressure drop and safe use.
Q:What's the function of the lighting transformer?
Illumination transformer: usually refers to the secondary output voltage for the safety voltage 24V - 36V, only for special lighting power supply using voltage converter.
Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Because of the brightness of the 36V safety voltage lamp brightness in the overhaul work is not enough, so now the well lighting design should not be 36V, and replaced by 220V, and only need to add a leakage protector on it.
Q:Can the 500 volt lighting transformer be changed into an electric welder?
The no-load voltage is higher (about 70~90 V), the arc can be smoothly started, and the voltage will be reduced to about 30 V when welding.
Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
We hold the service idea of "high beginning and high standard", in order to get rid of the condition of low level competition. We promise that our products are always advanced, steady, and long-lasting. We will keep up the product value and realized clients' dream by consistent innovation. We will absorb the latest research outputs, and keep an open mind to study from top enterprises. On the basis of independence, we strongly believe that we can become a new bright star through perseverance.

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2011
Annual Output Value
Main Markets North America 10.00%
South America 2.00%
Eastern Europe 20.00%
Oceania 20.00%
Mid East 2.00%
Eastern Asia 1.00%
Western Europe 40.00%
Southern Europe 5.00%
Company Certifications ETL; C-tick; CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen,HK
Export Percentage 91% - 100%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: Below 1,000 square meters
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords