This Generator powered cooperating with AVL 



 

ModelEngine ModelRated Power (KW)Standby Power (KW)

Engine

power (kw/r/min)

FUELL×W×H (MM)Weight (KG)
(L/H)
FKS-500G6190ZLD500550540/15001234950*1500*23507800
FKS-6008190ZLC600660720/1500143.55200*1650*23508900
FKS-800Z12V190B800880882/15001645300*1970*278013600
FKS-900G12V190ZL19009901000/15002055300*2040*270013800
FKS-1000A12V190ZLD100011001200/15002466250*2250*275019300
FKS-1200BH12V190ZL120013201360/1500266.56380*2200*265018500
FKS-1500H12V190ZLD150016501580/1500348.57880*2850*320021000
FKS-2000H16V190ZL200022002200/15004929060*2870*320024000

Specifications

This Generator by cooperating with AVL 

 

ModelEngine ModelRated Power (KW)Standby Power (KW)

Engine

power (kw/r/min)

FUELL×W×H (MM)Weight (KG)
(L/H)
FKS-500G6190ZLD500550540/15001234950*1500*23507800
FKS-6008190ZLC600660720/1500143.55200*1650*23508900
FKS-800Z12V190B800880882/15001645300*1970*278013600
FKS-900G12V190ZL19009901000/15002055300*2040*270013800
FKS-1000A12V190ZLD100011001200/15002466250*2250*275019300
FKS-1200BH12V190ZL120013201360/1500266.56380*2200*265018500
FKS-1500H12V190ZLD150016501580/1500348.57880*2850*320021000
FKS-2000H16V190ZL200022002200/15004929060*2870*320024000


Q:How to shut off the diesel generator
Emergency situations can press the emergency stop button can be forced to stop.
Q:I am purchasing a LARGE MOBILE TRAILER to be my mobile workshop. I wonder which would best regarding fumes and general maintenance. Onan approx. 7000w is my preffered choice at this point.
You might be able to get a generator that runs on a combination. These things make a lot of noise, a lot. Your consideration might hinge on one that can be fitted with wheels to move away from your working area. My father had a travel trailer and welded a small generator to the metal frame of the trailer. He did a lot of things he shouldn't do. It was so loud inside the trailer it was impossible to stay inside it. Also, the vibrations throughout the trailer were like an earthquake. So, if you're thinking of welding or bolting it onto your trailer, I'd be sure that it's not going to vibrate you to death.
Q:I am installing a 7,7 KW diesel 110v generator on my boat. I need to know the main breaker disconnect size in amps
7.7KW okorder
Q:Any places that can supply CHEAP diesel generators.i don't care about the voltage output.Price range about ?100 - ?300.
There okorder
Q:Can u plz help me to solve following problems:1.After an AC generator has been paralleled explain how the following are achieved for the incoming generator(i)Correct kW load sharing(ii)Correct load current when the generator has a different power factor to the other generators2. the cumulative damage that may be caused when the alternators are incorrectly synchronized3.For alternators operating in parallel the consequences of:(i)reduced torque from the prime mover of one machine(ii)reduced excitation on one machine
1 by adjusting governor setting load can be increased load limit can be increased on some goivernor adjusting exciation great danger if incorrectly synchronized,Turbine thrown out of base by huge magnetic shock or shearing of coup;ling with generaot reduced torque load will decrease kva will decrease
Q:I am contemplating on getting a full house generator and need some feedback from you all.l. What is the best brand for quality and durability of a generator and what hp would I needThe house is about 2,000/sq ft, central A/C heat, all electric at the moment with the usual appliances.2. I want to connect permanently to breaker box for automatic turn on and will need fuel for it.3. In light of today's economy and potential collapse if one is in survival mode, is it better or cheaper to have butane or propane ?Also what size tank would need to buy, and how big is reasonable ? to last a good while or as needed.I am totally electric right now including water well pump so when power down, I'm sunk!!
With electric heat, you're into a large generator. 'Automatic on' means a transfer switch generator control panel. If you're thinking about 'survival mode' diesel is your best fuel option. (More widely available, less tech. support for refueling, and stores well.) You might consider an engine heat capture system for efficiency in winter conditions. You probably need about 20-25KVA to handle full load with heating. (That's only a 'guestimate, DO do the math before you select a unit.) This won't be cheap.
Q:I want to run 4 lamps of 1000 watt on diesel engine. I want to check that is 6 kw output generator is sufficient for same. I want full calculation for this, losses etc
You want to connect a 4 kw load to a 6 kw generator. As long as the 6 kw (6,000 watts) rating of the generator is accurate it should power the lamps fine. You're only using 66% of the generator capacity. There aren't any significant losses to worry about and no point in doing any calculations. They were done for you in the kw rating of the generator. Just don't use any extension cords that are too small for the lights.
Q:What is the maximum power of a diesel generator
The diesel is ignited and the mixture is heated and the volume is rapidly expanding.
Q:and diesel generator and ATS that switches between two electrical sources ??
There may be no difference. It will depend on the application. For example, if I specified an ATS that had the proper voltage and current capacities, the only other item of concern would be to determine if the transfer would be a make before break or a break before make type of transfer. In a make before break, it would mean the sources would be placed into parallel operating condition before one of the sources was interrupted. This would require the ability to synchronize the sources. Which means the frequency, voltage and phase relationship of the sources must match before they are placed into parallel service. On a break before make switch, usually only phase rotation and approximate voltage levels are of concern. Hope this helps, Newton1Law
Q:For 100Kw generator, what will be minimum/ maximum loadfor its safe operation.
The maximum load will be given by the exhaust temperature, regardless of the nameplate rating. There is a maximum steady state temperature, which can be exceeded for short periods, say, 10 to 20 %, given by the engine mfr. The minimum load for an engine which runs at constant speed, i.e., a power generator, is about 50%. Below that it starts to shake dangerously. . .

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords