Desktop Switching Power Adapter 30-42 Watt
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 3000 Pieces per Day pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Features:
Universal Input: 100-240V AC 50/60Hz
Safety: UL/CUL/TUV/GS/CE/CCC compliance
RoHS Compliance
High efficiency & low power consumption
LED power indicator
Short Circuit Protection
Over Current Protection
Over Voltage Protection
Light Weight & Compact
Environmental:
Operating Temperature: 0 ~ +40
Storage Temperature: -40 ~+70
Operating Humidity: 10% ~ 90% RH Non-condensing
Storage Humidity: 5% ~ 95% RH Non-condensing
Mechanical:
Dimensions: 109mm(L)*51.5mm(W)*37mm(H)
N.W.:260g
AC Input Plug: EU,US,UK,AUS,etc. type according to customer's choice
Output plug: according to customer's requirements
Output Specifications:
Model | Output Load Voltage (V) | Max. Load Current (A) |
YS42-XX360 | 36 | 1.20 |
YS42-XX240 | 24 | 1.50 |
YS42-XX180 | 18 | 2.56 |
YS42-XX150 | 15 | 2.50 |
YS42-XX120 | 12 | 3.50 |
YS42-XX050 | 5 | 5.00 |
XX-represent rated output power
Packing details:
1 piece per plastic bag + inner box
50PCS/CTN
CTN Dimension: 34*31*37CM
- Q:Power and lighting transformers, lighting quality will be affected much?
- Corresponding to the transformer power supply, in order to save costs and reduce costs, the choice of AC ignition method is better. Pure resistive load, the power factor is 1. The 3 *100W=300W is the capacity of the required transformer
- Q:Is the substation separate from the power and illumination transformer?
- The power and lighting power supply in the substation need not be separated. In a large capacity power plant, the lighting can be electrically powered to ensure that the generator is stopped. The lighting source is often separated from the lighting transformer and powered by other power supplies.
- Q:3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
- The bulb is used in the two luminescence tube combined type lamp holder, the calculation process is very complex. Different combinations, the secondary voltage is different. Because it is a DC ignition, but also consider the efficiency of rectification, but the total power is constant.
- Q:How to calculate the rated capacity of small transformers for lighting purposes?
- But in fact, consider the total load, the importance, the location of the machine, and the future additional plan, according to the following order.
- Q:Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- Connection mode:N circuit breaker is caused by breaker of outlet line of transformer main cabinet.The branch circuit breaker divides the power, the electricity and the lighting power.
- Q:How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Voltage x current = power, in general we are using the total power of 2/3, you can press this type of calculation, if the installation of electrodeless lights, the line should be separated,
- Q:How is the lighting power of the 380V transformer calculated?
- With a light bulb with 4KVA load, the premise of the distance can be Mrs. face light bulb, dark can light the best load, 3KVA bulb brightness
- Q:Why is the two side of the lighting transformer grounded?
- The metal shell transformer grounding grounding protection is called: under normal circumstances is not charged, electrical metal and in the damaged insulation or other circumstances may be charged part (i.e. metal structure and insulation electrical parts part) and grounding wire connected to a reliable way to protect people.
- Q:Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- What you think? Your light is 220V, right. Over 36V, it's better not to live with electricity unless there is good protection
- Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
1. Manufacturer Overview |
|
---|---|
Location | Zhejiang, China |
Year Established | 1999 |
Annual Output Value | |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO 9001:2000;ISO 14001:2004;GS;TUV |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | 91% - 100% |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | 10,000-30,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered |
Product Price Range |
Send your message to us
Desktop Switching Power Adapter 30-42 Watt
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 3000 Pieces per Day pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords