DBM-is produced using selected natural magnesite that is purified and is calcined in a shaft kiln.The final product is used for electric furnacefloors and furnace liner tamping.

Many typical specification as following :

Grade

MgO

(min.)

SiO2

(max.)

CaO

(max.)

Fe2O3

(max.)

Al2O3

(max.)

L.O.I.

(typical)

mesh

DBM90

90.00%

1.00%

1.50%

0.70%

0.10%

1.70%

0-400

DBM95

95.00%

1.00%

1.50%

0.80%

0.10%

2.60%

DBM96

96.00%

1.50%

2.50%

0.80%

0.30%

2.90%

DBM97

97.00%

3.00%

2.50%

0.80%

0.30%

3.40%

Packaging & Shipping of DBM :

Packaging: 1.25MT jumbo bags or 1MT jumbo bags

Delivery details: according to customers’ requirements

Application of DBM:

1.Mainly used in processing raw materials of different magnesia refractory,

2.The production of steel lining the bottom and ramming mixes;

3.The raw materials of magnesia brick and magnesia-chrome brick;

4.Used electric steel making furnace, heating furnace, non-ferrous metals blowing converter furnace the bottom and the lining of the refractory materials.

Q:How to determine the fire resistance rating of the aluminium-plastic?panel?
The fire resistance rating of the aluminium-plastic?panel is determined by two indicators, namely national compulsory standard of GB8624 "Building Materials Combustion Performance Grading Method ", and GB/T17748 "Aluminium-plastic?Composite Panel National Standard" . Classifications of combustion performance of building materials in our country are as follows: A class: Incombustible building materials; B1 class: Flame-retardant building materials; B2 class: combustible building material; B3 class: flammable building materials. The fire resistance rating of the aluminium-plastic composite panel shuld be no less than B1 class. 1. Detection indexes and requirements of fireproof aluminum-plastic composite panel (B1 class): (1) Conduct the test according to GB/T8625-88, the average leftover length of each test specimen should be more than 150mm, (any test piece should have leftover length), and the maximum average flue gas temperature of each test should be no more than 200 ℃; (2) Conduct the test according to GB/T8626-88, flame hight indicators.
Q:Does anyone know about the classification standards of B2-level fireproof and thermal insulation materials?
1.The insulation materials with A-level combustion performance: EPS Hairong module, rock wool, glass wool, foam glass, ceramic foam, foam cement, closed-cell perlite, etc. 2. The insulation materials with B1-level combustion performance: specially-treated extruded polystyrene boards(XPS)/ specially-treated Polyurethane(PU), Phenolics, Polystyrene rubber powder particles,etc. 3. The insulation materials with B2-level combustion performance: Expanded polystyrene sheets(EPS), Extruded polystyrene boards(XPS), Polyurethane(PU), Polyethylene(PE), etc. See the 2009 measures of building technology. The A-level insulation material is only fireproof, the insulation performance of it is worse than that of organic XPS \\\\ EPS material. Currently I think that the best insulation material should be Hairong EPS module, it not only achieves the requirement of insulation but also fulfills the goal of fireproofing, and the comprehensive unit price of it is not expensive. The insulation materials in the domestic market have their own disadvantages, you'd better take the building demands into consideration, and use the materials that are within the acceptable range.
Q:which kind of material should be used in fireproofing cabinet?
Cabinet fireproof?panel can be divided into fiber cement fireproofing board, metal fireproof?panel, mineral wool fireproof?panel, perlite fireproof?panel and many other fireproof?panels. Wherein fiber cement fireproofing board is a new material with growing popularity , it has good thermal insulation and sound insulation performance and belongs to a1 level fireproofing material. Fiber cement fireproofing board is a kind of decoration sheet that takes silicious material or calcareous material as the main raw materials and is made by being combined with fibrous material and other additives in certain proportion. Metal fireproof?panel is a kind of sandwich dalle that takes aluminium plate, stainless steel plate, colorful steel plate and other metal materials as main raw materials and is made by adding some fire?retardant materials. Mineral wool board is a kind of fireproofing decorative board that takes mineral wool and glass wool as the main raw materials. Perlite fireproof panel is a kind of fireproofing hollow plate that take low alkalinity cement as the main materials and fireproofing perlite as filler.
Q:What are the best refractory materials in 2,400 Celsius degree?
It is the purpose that decides what kind of materials you should use. What you have said is 2,400 Celsius degree, right? It is about the fire resistance of the material or the required temperature of it?
Q:What are the application of old refractory bricks?
It can be used for refractory bricks again, as long as the quality is good. It is much more cost-effective than Bayerite.
Q:Is it normal for caable fire resistant material to catch on fire?
Abnormal, preventive measures: 1 take fire preventive measures. Measures taken for fire retardant measures of cable: (1) seal closely with fire resistant materials holes ran by cables through walls, shafts to prevent the cable fire, high temperature gas diffusion and spread when cables are on fire. (2) to wrap the cable with the insulation refractory material, when the cable is surrounded with fire, warpped cable is insulated by the insulation material from fire, so it will not be burned. If the cable itself is on fire, fire will be extinguished thankes to lack of oxygen in warpped cable, to avoid the fire to spread out. 2 to strengthen the cable circuit switch and regular protective check and maintenance, to ensure that the action is reliable. 3 to strengthen the cable operation and monitoring, to avoid the overload of the cable operation. . 4 regularly clean dust on the cable, to prevent cable from catching on fire due to the accumulation of dust. 5 to ensure the construction quality, the quality the cable must be strictly in line with the requirements and standards. 6 cable laying should maintain enough distance form the heat pipe, control cable is no longer than 0.5 meters; power cable is no longer than l meters. Control cable and power cable should be divided into slots, be layered and seperated instead of being overlapped . For the parts that do not meet the requirements, measures must be taken to insulate heat and fire. 7 regularly teat cable , abnormal problem should be handled in a timely manner. 8 install fire alarm so that fire will be discovered on time, and cables will not catch on fire. 9 the cable trench should be kept dry to prevent the cable from being affected with damp, or leading to declined insulating function and short circuit.
Q:Which refractory quality inspection authority is good?
Research Institue of Refractory Materials in Luoyang, Henan Some of our samples are made there.
Q:What's the A class fireproof and thermal inuslation matertial for external wall?
It is a kind of green and environmental protection inorganic material, free of harmful substances like asbestos, benzene, formaldehyde, etc. Its fire resistance can be up to A1grade non-combustible material, which means it can endure the highest temperature of 1400 ℃. It is thermal insulating with low heat conductivity and high heat storage coefficient. It has good weather resistance, finished product stability, anti hollowing, crack resistance, wind pressure and shock resistance with the same service life as buildings of 70 years. It is water-fast and moistureproof, breathable but waterproof, and fungusproof without influence from steam. It is convenient in construction which omits many procedures of panels construction. Once the second plastering is finished, the construction is completed, which greatly shortens the construction period. It has good adhesive property with various base planes, and meanwhile its external exposed surface can choose coating, facing brick, aluminum sheet, marble, etc. It saves money. Excellent construction technology reduces the construction cost. It effectively prevents the panels from leakage at the external wall, window, eave, etc. which saves the subsequent maintenance fund. It provides timely delivery. With sufficient supplies of raw materials and convenient production, it is fast in delivery.
Q:How to distinguish the fire resistant level of construction materials?
There are 3 conditions for building components to reach fire endurance, namely: Loss of ability to support; loss of integrity; loss of fire insulation function. As long as one condition occurs, fire endurance is reached and the time before it is called fire endurance. 1), loss of ability to support: If the specimen bearing capacity and rigidity reduce, section area shrink, collapses or deformation exceeds specified numerical value because it cannot bear the load of original design under flame or high temperature, it loses the ability to support. 2), loss of integrity: It mainly refers to the thin wall separating component(such as stairs, windows,partitions, ceiling, etc.) burst or partially collapse under flame or high temperature, and penetrating?fracture or opening appears, and the reverse side even burn. For example, when the floor is under flame or at high temperature, the flame spread to the upper room, which indicates that the integrity has been damaged. 3), loss of fire insulation function: It mainly refers to that seperating components loses thermal insulation and excessive heat conduction. In experiment, if the average temperature of component unexposed surface exceeds 140 ℃, or if any spot at the unexposed surface exceed the initial temperature of 180 ℃, the component loses fire insulation function.
Q:Does anyone know what is the use of waste refractory materials?
Waste refractory materials can be 1, Recycled to do the aggregate and powder of castable , or make bricks. 2, can be reused after smash.3, Metal silicon is an anti oxidant in refractory material, mainly functioning as he oxidation resistance, at the same time improve its toughness.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords