DEAD BURNT MAGNESITE 0-30MM

Ref Price:
Loading Port:
Dalian
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
2000 m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

ItemMgOSiO2CaOLOIB.D.(g/cm3)
DBM-97970.71.40.23.2
DBM-96961.51.50.23.2
DBM-95952.21.60.33.2
DBM-949431.60.33.2
DBM-93933.51.60.33.2
DBM-929241.60.33.18
DBM-929241.60.33.18
DBM-91914.51.60.33.18
DBM-90904.820.33.18
DBM-878772.20.33.2

Dead burned magnesite- DBM-is produced using selected natural magnesite that is purified and is calcined in a shaft kiln.The final product is used for electric furnacefloors and furnace liner tamping.

Main products level :

0-1mm;1-3mm;3-5mm;0-10mm;0-30mm

50 to 325mesh (90% through)

Product feature:

high temperature performance and high-density, strong anti-permeability ability and easy to rapid sintering, very thin sintered layer,good thermal shock stability, strong slag-resistance, long service life and so on.

Product function:

Apply to the construction of bottom and wall of all kinds steel making electric arc furnace and ferroalloy smelting furnace for hot charging of hot metal and second hand steel

Product usage:

Mainly used in producing common magnesite brick, magnesite aluminum brick, magnesite chrome brick, gunning mix, hot patching mix for converter and EAF ect .

Product Advantage:

Our factory produce the products of the Dead-burned magnesite are selected natural magnesite, it is produced by mine-selecting, purifying, calcimine in shaft kiln. It is an ideal material for unshaped refractory material, the final products are used in open hearth furnace, electric furnace bottom and furnace's lining tamping.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is fire retardant coating mainly used for?
Fire retardant coating is a coating which is applied to the surface of buildings and structures and can form a protective layer of fire retardancy and thermal insulation. It can reduce the flammability of the coated materials and block the rapid spread of fire so as to improve fire endurance of the coated materials. Features of fire retardant coating: (1) Fire retardant coating itself has a flame-retardancy or non-inflammability, and it can prevent the protected substrate from direct contact with the air, and delay ignition and reduce the burning speed of the objects. (2) In addition to flame retardancy or non-inflammability, the fire retardant coating itself has a a low thermal conductivity, which can delay the transfer of flame temperature to the substrate to be protected. (3) When heating, fire retardant coating decomposes non-combustible inert gas to dilute the combustible gas decomposed by the protected, making it difficult to burn or slow down the burning rate. (4) Fire retardant coating containing nitrogen will decomposite NO, NH3 and other basic groups, which compound with the organic radicals and interrupt the chain reaction so as to reduce the temperature. (5) intumescent fire retardant coating will expand and foam when heating, and form a carbon foam insulation to block the protected objects, thus delaying the transmission of heat to the substrate.
Q:How to distinguish the fire resistant level of the rubber and plastic thermal insulation material?
It is divided into level A, B1, B2 and B3. According to the current "burning behavior of building materials classification method", Level A insulation material is a non-combustible material, which belongs to YT. However, from the point of view of the current market , level A insulation material are very few, only glass wool, rock wool board, foam glass and vitrified micro bead. However, compared with level A insulation material, the more welcomed by the market is the organic insulation material. This is characterized as thermal insulation material, which is divided into three levels: level B1 is flame retardant, level B2 is flammable and level B3 is flammable. The level B1 nonflammable thermal insulation material is determined according to the fire endurance of the material. And different parts of the material are divided differently! Such as the common EPS / XPS insulation boards through special treatment of adding flame retardant. . Level B2 combustible insulation material is commonly the EPS expanded polystyrene foam insulation board and XPS board, that is, the ordinary plate. This material has low ignition point, and releases large amounts of harmful gases in the combustion process . Level B3 flammable insulation material is commonly the thermal insulation material taking polystyrene foam as the main material. Since this material is highly flammable, it has been out of the external wall thermal insulation materials. As for the civil construction insulation materials, China's current popular building insulation materials in the market are mainly made of three organic foams: EPS (molded polystyrene board), XPS (extruded polystyrene board) and PU (polyurethane).
Q:Which manufacturers have the best fire-proof materials with light weight?
Recommend Hubei Boyuejia Industrial Co., Ltd. It is a specialized high-tech enterprise that integrates research and development, production, sale and installation of new lightweight fireproof partition panel, partition panel, new partition panel and mechanical equipment. Products are lightweight, fireproof, waterproof, sound insulation, thermal insulation, fracture resistance, anti-permeability, environmental protection, strong constitutive property (dense humidity) and other superior performances. It can be widely used in all types of lightweight wall panel of all kinds of buildings, and is one of the preferred materials of plant, residence, hotel, office building and public buildings.
Q:Who knows how to divide the building fire grade and fire resistance grade?
I hope to help you building fireproof rank division is one of the most basic measure in building fire safety technical measures, Building's fireproof rank is divided into class one, two, three, four according to China's architectural design specification. Fire-resistant capability of the highest level is the strongest; Fire resistance of four level of the weakest. The fire resistance level of a building depends on the combustion performance and fire resistance of the building components that comprise the building. The so-called building component refers to a series of basic components, such as wall, foundation, beam, column, floor, stair, ceiling and so on. The judgment condition of the fire resistance There are three conditions for components' fire resistance limit to be reached, namely, the fire resistance limit of the building component: Loss of support and integrity; loss of time to fire the role of the time; as long as any of these three conditions is met, it will reach its limit of fire. Hope my answer will help you.
Q:Who knows about the differences between 3M fireproofing materials and ShiLiDe materials?
ShiLiDe materials are rubbish which can not used in many industries now, because the main materials of which are mineral wool boards. These boards are harmful to human body, will lead to chronic poisoning, and the quality of which is bad! You must pay attention to it! They can not be used in chemical and pharmaceutical plants.
Q:Can polystyrene foam color steel plate be used as decorative fireproofing material ?
As far as I am concerned, polystyrene foam color steel plate cannot be used as decorative fireproofing material. Because polystyrene flame retardant and non-flame retardant of the points, from the fire retardant is generally self-extinguishing. Polystyrene is the polymer synthesized by styrene monomer through free radicals polycondensation reaction. It is a transparent thermoplastic plastic. With above 100 ℃ glass transfering temperature,it is often used to make a variety of disposable container and disposable foam lunch box which have to withstand the boiling water temperature.
Q:whether the aluminum silicate thermal insulation material is fireproof or not?
aluminum silicate is fireproof, and the melting point is between -40 ~ 800 ℃. Aluminum: it takes the flint clay clinker as raw material, produced by resistance or electric arc furnace fusion and injection fiber-forming process. its characteristics: Low thermal conductivity, excellent thermal and chemical stability, without binder and corrosive material.
Q:Fire rating of decoration materials
code for fire protection design of buildings
Q:What is shapeless refractory?
Q:What type of firebrick does TZ-3 represent?
It is the standard brick.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range