Product Description:

The cable is manufactured according to the standards of ISO/EIC11801EIA/TIA-568-B and YD/T1019-2001.

    Using a single copper conductor, XLPE insulated, PVC, PE or low-smoke halogen-free sheath

    Cable is mainly used for integrated wiring network ISDN,

Type

        Structure type

Conductor diameter mm

Insulation

diameter mm

Pair

Cable diameter mm

CAT-5

UTPUnshielded

0.51

0.92

4

5.6

FTP(Aluminum foil overallshield )

0.51

0.92

4

5.8

SUTP(Aluminum foil +

Braided general shielding

0.51

0.92

4

6.3

CAT-5e

UTPUnshielded

0.51

0.92

4

6.3

FTP(Aluminum foil overallshield)

0.51

0.92

4

6.3

SUTP(Aluminum foil +

Braided general shielding

0.51

0.92

4

6.7

CAT-6

UTPUnshielded

0.57

1.00

4

6.7

FTP(Aluminum foil overall shield)

0.57

1.00

4

6.9

SUTP(Aluminum foil +

Braided general shielding

0.57

1.00

4

7.5

Type

   Frequency

MHz

Work data

CAT-5

CAT-5E

CAT-6

DC resistance of conductor  Ω/100m


9.5

9.5

6.6

characteristic impedance   Ω


100±15

100±15

100±15

Max.working capacitance

         pF/100m


5.6

5.6

5.0

Transmission speed


0.65

0.65

0.65

Maximum attenuation  db/100m

1

2.0

2.0

1.9

4

4.1

4.1

3.7

10

6.5

6.5

5.9

31.25

11.7

11.7

10.6

62.5

17.0

17.0

15.4

100

22.0

22.0

19.8

200

/

/

29.0

250

/

/

32.8

Minimum near end crosstalk attenuation   db/100m

1

62

65

74

4

53

56

65

10

47

50

59

31.25

40

43

52

62.5

35

38

47

100

32

35

44

200

/

/

40

250

/

/

38

Minimum far end crosstalk attenuation    db/100m

1

61

64

68

4

49

52

56

10

41

44

48

31.25

31

34

38

62.5

25

28

32

100

21

24

28

200

/

/

22

250

/

/

20

Minimum return loss db/100m

1

23

20

20

4

23

23

23

10

23

25

25

31.25

21.1

24

24

62.5

181

22

22

100

16

20

20

200

/

/

18

250

/

/

17


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Emergency cable T-box and cable distribution box of the information?
The incoming and outgoing wires are electrically connected together The potential is the same, which is suitable for tapping or branch wiring It is common practice to add the number of lines back to the number of times The three-branch cable splitter box, which has three equipotential bonding points on each phase, can be used as a second or two-in-one Cable distribution box contains U, V, W three-phase, three-phase circuit structure is the same, along the row together 2 High-level distribution box High-level distribution box containing switching equipment, both from the ordinary distribution box of the tap, branch, but also from the power supply circuit control, conversion and change the mode of operation The switch fence roughly divides the cable circuit into the inlet and outlet sides, and the potential on both sides can be different The switchgear itself has a larger volume, so the high-level distribution box size is relatively large, the height is generally 14 ~ 18m, the depth of about 09 ~ 10m, the length of the number of switching devices according to the number, M to 24 m The shape of the box is similar to that of an outdoor box transformer, and there are a number of active doors on the shell Some doors are designed for the operation of the switchgear Some doors are provided for the installation or maintenance of the cable connection device The
Q:Which has, know the power of the electrical, choose the cable formulas. And explain it
Basically are refining, the wax is also used, the high cost of particles
Q:The power cable troughs are divided once and twice
Can be used for overhead, buried and pipeline laying of the cable line
Q:What is the use of wire and cable per square meter of residential building?
You can use sc. if too long, or bend the best use of the bridge
Q:What is the difference between a pre-branch cable and a punched clip?
1 Latex reclaimed rubber, the use of Malaysia imported rubber tree waste plastic cups, plastic yarn and latex products factory condensed waste as raw materials, with Ji Dai flooding fried ghosts kill Handan fine fineness, easy color, , Feel good elasticity, high elongation at break, no need to plastic and so on
Q:What are the requirements for the spacing between the strong and weak wires?
with a white cable to facilitate the distinction between the cable
Q:Power cable casing buried what are the requirements
2 direct laying cable way, should meet the following requirements: 1 cable should be laid in the trenches, and should be along the length of the cable on the next, next to the side of the shop with a thickness of not less than 100mm soft soil or sand 2 along the length of the cable should cover the width of not less than 50mm on both sides of the cable protection board, protective board should adopt concrete 3 urban cable buried in the laying, it is appropriate in the protection board laying eye-catching signs 4 in the suburbs or open areas, along the cable path of the line spacing of 100m, corner or joint parts, should be erected obvious signs or signs 5 when the use of cable through the corrugated pipe laying in the trenches, should be along the full length of the bellows casting thickness of not less than 100mm of concrete, the width should not be less than 50mm outside the tube, the cable can not armor 3 buried in the non-frozen soil area, the cable embedding depth should meet the following requirements: 1 cable to the basement of the basement structure, not less than 03m 2 cable skin to the ground depth, not less than 07m; when located in the carriageway or farmland, should be properly deepened, and should not be less than 10m 4 buried in the permafrost area, should be buried below the permafrost layer, when not buried can be buried in the soil drainage of dry frozen soil or backfill, but also take other measures to prevent damage to the cable The 5 Directly laying the cable, is strictly prohibited in the underground pipe is just above or below The minimum distance between cable and cable, pipe, road, structure, etc shall be in accordance with Table 535 Table 535 Permissible minimum distance between cable and cable, pipe, road, structure, etc (m)
Q:Why my home analog TV connected to the digital TV set-top box after the screen is black and white
The middle is to connect the two cables together, the terminal is connected to the equipment
Q:The difference between the instrument cable and the low voltage power cable
Surface brush fireproof paint is the fire-resistant bridge by fire time sub-level two three times as if 30 minutes 45 minutes and 60 minutes fire bridge should be lined with inorganic fire board, but this is very high in the general very little useful
Q:Wire and cable manufacturing process (to be detailed)?
Tell you an electrician commonly used "empirical formula": as long as the copper wire, cross-sectional area per square millimeter can be safely through the 4 - 5A rated current; in 220V single-phase circuit, the power per 1KW, the current For the 4.5A or so, in the 380V three-phase balanced circuit, the power per 1KW, the current is about 2A, the above values can be calculated using the physical formula is very close to the results, so the electrician at work, in order to Do not remember those "cumbersome" formula, remember that these can. Then according to this algorithm to know: every 1 mm square cross-sectional area of the copper wire, if used in 220V single-phase circuit, you can safely carry 1KW load through the current, if used in three-phase balanced load (such as motor) Circuit, you can safely carry 2.5KW load through the current

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range