Copper Wire Tape Screen Cable Multi Screen Cable

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10000 m
Supply Capability:
1000000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications of Copper Wire Tape Screen Cable Multi Screen Cable   

PVC sheath solid conductor electrical wire 
ISO 9001-2008 
Voltage: 450/750V 
Cross section:1.0mm2 to 500mm2 
OEM acceptance

Solid copper conductor Copper Wire Tape Screen Cable Multi Screen Cable 

 

1.electrical wire is usually PVC insulated wire

PVC insulation no-sheathed general purpose electrical wire,single core,solid

2.sheathed round wires:

copper(aluminum)conductor pvc insulated pvc sheathed solid wires

copper(aluminum)conductor pvc insulated pvc sheathed flexible wires

Sizes:0.5-185mm2

3.products can be produced and provided accroding to standard G/T5023,IEC60227,BS6004,JB8734.

Standard:

GB/T5023.1-1997  450/750V or below PVC insulated electric wires.

GB/T5023.1-1997 is identical to IEC227,models are the same,can be produced according to customers requirement.

Using purpose:

4. used for AC rated voltage 450/750V and below for the followings:

lighting,electrical installation,the connection between instrumention and telecomunication equipment

 

Technical Data Sheet of Copper Wire Tape Screen Cable Multi Screen Cable  

Class 2 Conductor

Nominal
sectional area
mm2

Conductor
No/Dia.
mm

Nominal
Insulated thick
mm

Max overall
Dia.
mm

Condcutor
Resistance at
20

Weight
Kg/km

Cu

Al

Cu

Al

1.5

1/1.38

0.7

3.3

12.1

-

19.2

-

2.5

1/1.78

0.8

3.9

7.41

11.8

30.8

15.0

4

1/2.25

0.8

4.4

4.61

7.39

45.5

21.0

6

1/2.76

0.8

4.9

3.08

4.91

65.0

29.0

10

7/1.35

1.0

7.0

1.83

3.08

110.0

52.0

16

7/1.70

1.0

8.0

1.15

1.91

170.0

70.0

25

7/2.14

1.2

10.0

0.727

1.20

270.0

110.0

35

7/2.52

1.2

11.5

0.524

0.868

364.0

150.0

50

19/1.78

1.4

13.0

0.387

0.641

500.0

200.0

70

19/2.14

1.4

15.0

0.268

0.443

688.0

269.0

95

19/2.52

1.6

17.5

0.193

0.320

953.0

360.0

120

37/2.03

1.6

19.0

0.153

0.253

1168.0

449.0

150

37/2.25

1.8

21.0

0.124

0.206

1466.0

551.0

185

37/2.52

2.0

32.5

0.099

0.164

1808.0

668.0

 

 Class 5 Conductor of Copper Wire Tape Screen Cable Multi Screen Cable  

Nominal
sectional area
mm2

Conductor
No/Dia.
mm

Nominal
Insulated thick
mm

Max overall
Dia.
mm

Condcutor
Resistance at
20

Min insulated
resistance at
70MΩ/km

Weight
Kg/km

2.5

9/0.41

0.8

4.2

7.41

0.011

33.0

4

19/0.52

0.8

4.8

4.61

0.009

48.0

6

19/0.64

0.8

5.6

3.08

0.0084

68.0

10

49/0.52

1.0

7.6

1.83

0.0072

115.0

16

49/0.64

1.0

8.8

1.15

0.0062

176.0

25

98/0.58

1.2

11.0

0.727

0.0058

272.0

35

133/0.58

1.2

12.5

0.524

0.0052

384.0

50

133/0.68

1.4

16.5

0.387

0.0051

510.0

70

189/0.68

1.4

16.5

0.268

0.0045

714.0

95

259/0.68

1.

19.5

0.139

0.0035

965.0

120

259/0.76

1.8

22.0

0.153

0.0032

1210.0

150

259/0.85

1.8

25.0

0.124

0.0032

1510.0

 

Pictures of  Copper Wire Tape Screen Cable Multi Screen Cable    

Copper Wire Tape Screen Cable Multi Screen Cable



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the cable for rvv? Is it a power cable or a control cable? What is the cable?
The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
Q:Buy Taipower c 450P with remote control to add audio and video cable
Set-top box with the AV cable connection: yellow - video, red and white - audio, corresponding to the TV's AV input interface can be connected (do not receive the TV component interface). As for the emergence of partial pink, the possible reasons are: . poor contact. You will re-connect the three-color AV cable to the set-top box, on the TV, to ensure good contact. . cable quality. Three-color AV cable may not be the quality, if you can replace a group of try, or use the DVD and other equipment connected with the TV to test the AV line with or without problems. . TV AV input failure. You can use other video source equipment connected to the TV test, such as: DVD, VCD machines and so on. . set-top box failure. May be set-top box AV output port problems, if there are multiple sets of AV output, you can try other port okay, not the case may be the quality of set-top box, call customer service it.
Q:Wire printed on the word what way to erase
If you need an unqualified wire, you can contact this part
Q:Help look at such a configuration will not have compatibility issues! Do you need to improve? Budget in 5500 or so
This situation generally have to extend the line triangle can link the ground, the two feet when you use the foot to feel the foot, and step on the bench as long as the non-conductive feel. No seriousness
Q:Building decoration wiring pipe elbow with yellow wax tube can you?
and then the audio cable and video cable [audio line (red and white), the first time the signal line (white) Video line (yellow)】 corresponding to the color connection set-top box with TV
Q:What kind of KVM switch is this configuration below?
A 32 kvm, Taobao the lowest price, more than 4000 yuan, plus 30 control lines 30 * 20 = 600 yuan, if there is no control side of the mouse and mouse, need to add a thousand dollars. A total of about 6 thousand dollars. Two KVM cascade, .000 yuan * 2 = 2000 yuan, 620 yuan control line, the mouse was a thousand dollars, a total of nearly four thousand dollars. But the stability of multiple cascade is better than a single good.
Q:What does the letter of the computer cable model mean?
Cable regardless of the definition of the number of elements in the definition of a few such as: YJV-3 * 50 + 1 * 16 calculated the number of lines is always a different, different wire rules Model input: bv-2 * 2.5 / bv-3 * 4 (different material), bv-2 * 2.5 + 3 * 4 (the same material)
Q:How are various wire and cable models named?
Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
Q:Galvanized wire tube buried to do anti - corrosion do
Galvanized itself on the anti-corrosion, no need to do anti-corrosion treatment.
Q:Is there a difference between PE cable and PE water supply pipe?
Rubber over the bridge surface curing treatment, nice and at the same time to ensure a safe Pressure tonnage: 5 tons to 65 tons, indoor and outdoor are available (and provide only tramway) Uses: used in engineering department exhibition company, power company construction line, play a role in protecting the line Rubber trough ■ tough, insulated, high pressure (maximum load of 65 tons) rubber over the bridge ■ suitable for all outdoor weather, rain, lightning, moisture, flame retardant ■ surface non-slip surface texture ■ Position protection to the type of cable and communication data cable ■ unique design, no need to destroy the ground installation ■ durable, the surface of non-slip surface texture ■ simple installation, easy to move, structural design briefs practical ■ unique elbow, tee, Selection ■ 1 hole, 2 holes, 3 holes, 4 holes, 5 holes design, fully applicable to the exhibition, performing arts, workshops, power, communications, military and other industries 2 Specifications Table 1 Specifications 1000 × 130 × 20 aperture 40 × 13 Weight 12KG (for indoor cable signal line, etc) 2 Specifications 1000 × 275 × 40 aperture 105 × 30 Weight 32KG (for indoor wiring too thick if the wire, etc) 3 Specifications 1000 × 250 × 50 aperture 32 × 35 Weight 7KG (applicable Over motor vehicles and large trucks, etc) 4 Specifications 900 × 500 × 75 Aperture 50 × 60 Weight 19KG (for motor vehicles and forklifts, etc) 5 Specifications 900 × 500 × 75 Aperture 32 × 35 Weight 21KG (for the workshop workshop, such as truck ) 6 Specifications 900 × 620 × 110 Aperture 90 × 90 weight The amount of 28KG (for small trucks and large trucks, etc) 7 specifications 1000 × 310 × 55 aperture 35 × 35 weight 15KG (for workshop workshop forklift or private cars, etc) 8 specifications 770 × 485 × 65 aperture 40 × 40 weight 18KG For the workshop workshop plant forklift, etc)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range