Construction for XLPE Insulated Corrugated Aluminum Cable with 64/110kV

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
10000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Cross Section for Conductor
(mm)
Diameter for Conductor
(mm)
Wall Thickness for Conductor Shield
(mm)
Wall Thick ness for Insulation
(mm)
Wall Thick ness for Insulation Shield
(mm)
Wall Thick ness for Corrugated Aluminum Sheath
(mm)
Thickness for Outer Sheath
(mm)
Outer Diameter for cable
(mm)
24018.41.2 19.0 1.22.04.089.0
30020.61.218.51.22.04.090.2
40023.81.217.51.22.04.091.4
50026.61.217.01.22.04.093.2
63030.01.216.51.22.04.596.6
80034.01.216.01.22.04.599.6
100038.61.516.01.22.04.5108.3
120042.01.516.01.22.35.0112.7
140045.01.516.01.22.35.0115.7
160049.21.516.01.22.35.0118.9
180051.01.516.01.22.45.0121.9
200054.01.516.01.22.55.0125.1
220057.51.516.01.22.55.0128.6
250060.01.516.01.22.55.0131.1
300067.11.516.01.22.75.0138.6



Total Weight for Cable
(kg/km)
CopperAluminum
Insulation and PVC SheathPE SheathInsulation and PVC SheathPE Sheath
8243.07842.06755.06354.0
8860.08453.06994.06586.0
9755.09343.07288.06875.0
10759.010337.07721.07299.0
12370.011881.08477.07988.0
14192.013686.09207.08701.0
17149.016598.010825.010274.0
19379.018743.011939.011303.0
21475.020821.012795.012141.0
23595.022923.013675.013003.0
25787.025097.014627.013937.0
28002.027293.015602.014893.0
30160.029430.016520.015790.0
32093.032349.017593.016849.0
38565377761996519176


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Cable WDZ-YJFE2 (4X185 + 1X95) what does it mean
Bracket spacing of the general level of not more than 2m, vertical not more than 1.5m according to the number of cable the number of levels can be used 1.5m a vertical 1m a relatively insurance
Q:Why does the AC welding machine burn out the equipment?
Electric workers in the wood when the wood bar, buried in the soil that part of the first use of fire char, and then brush into the ground after the bitumen
Q:Fourth, what causes the power cable fire accident
Once the cable in the event of fire, the fire ferocious, rapid spread, in the burning will occur when a large number of harmful gases, resulting in fighting difficulties
Q:Power cable 5-color line, respectively, what color, what role?
Copper core cross-linked polyethylene insulated double steel tape armored PVC sheathed power cable, rated voltage 8.7 / 15KV, three core, conductor cross-sectional area of 300mm2
Q:Power cable casing buried what are the requirements
2 direct laying cable way, should meet the following requirements: 1 cable should be laid in the trenches, and should be along the length of the cable on the next, next to the side of the shop with a thickness of not less than 100mm soft soil or sand 2 along the length of the cable should cover the width of not less than 50mm on both sides of the cable protection board, protective board should adopt concrete 3 urban cable buried in the laying, it is appropriate in the protection board laying eye-catching signs 4 in the suburbs or open areas, along the cable path of the line spacing of 100m, corner or joint parts, should be erected obvious signs or signs 5 when the use of cable through the corrugated pipe laying in the trenches, should be along the full length of the bellows casting thickness of not less than 100mm of concrete, the width should not be less than 50mm outside the tube, the cable can not armor 3 buried in the non-frozen soil area, the cable embedding depth should meet the following requirements: 1 cable to the basement of the basement structure, not less than 03m 2 cable skin to the ground depth, not less than 07m; when located in the carriageway or farmland, should be properly deepened, and should not be less than 10m 4 buried in the permafrost area, should be buried below the permafrost layer, when not buried can be buried in the soil drainage of dry frozen soil or backfill, but also take other measures to prevent damage to the cable The 5 Directly laying the cable, is strictly prohibited in the underground pipe is just above or below The minimum distance between cable and cable, pipe, road, structure, etc shall be in accordance with Table 535 Table 535 Permissible minimum distance between cable and cable, pipe, road, structure, etc (m)
Q:Where the computer can be a bare chassis. Which hardware inside the framework
Depending on how much of the 24 switches that U ah, 1U, then up to 42 slightly, but still empty position good heat dissipation, 2U, then installed a 20 up to the bar.
Q:What type of cable is the power cable?
It seems to have not heard of our unit to do the professional cable bridge to the current domestic ranking before 3 I did not see we have this certification ah there is a professional health and safety management system has an environmental management system and other quality management system Science and technology innovation patent what a lot did not see the CCC
Q:What recycled rubber is suitable for the production of wire and cable?
Symmetrical receptacles need to be treated differently, with color distinctions most convenient.
Q:Lighting wire, I do not know is it. The When to use BV1 * 2.5, when to use 2 * 2.5, when to use 3 * 2.5, when to use 4 * 2.5,
It does not look good, but also affect the wallpaper, wallpaper, in full swing, and then from the chain reaction, then it is worthless, it is recommended to use decorative decorations decorated, perhaps alone for more suitable wallpaper pattern or color ... that does not affect the wallpaper Can also play a decorative effect ... Thank you
Q:Wire and cable manufacturing process (to be detailed)?
Tell you an electrician commonly used "empirical formula": as long as the copper wire, cross-sectional area per square millimeter can be safely through the 4 - 5A rated current; in 220V single-phase circuit, the power per 1KW, the current For the 4.5A or so, in the 380V three-phase balanced circuit, the power per 1KW, the current is about 2A, the above values can be calculated using the physical formula is very close to the results, so the electrician at work, in order to Do not remember those "cumbersome" formula, remember that these can. Then according to this algorithm to know: every 1 mm square cross-sectional area of the copper wire, if used in 220V single-phase circuit, you can safely carry 1KW load through the current, if used in three-phase balanced load (such as motor) Circuit, you can safely carry 2.5KW load through the current

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range