Product Description:

Cross Section for Conductor
(mm)
Diameter for Conductor
(mm)
Wall Thickness for Conductor Shield
(mm)
Wall Thick ness for Insulation
(mm)
Wall Thick ness for Insulation Shield
(mm)
Wall Thick ness for Corrugated Aluminum Sheath
(mm)
Thickness for Outer Sheath
(mm)
Outer Diameter for cable
(mm)
24018.41.2 19.0 1.22.04.089.0
30020.61.218.51.22.04.090.2
40023.81.217.51.22.04.091.4
50026.61.217.01.22.04.093.2
63030.01.216.51.22.04.596.6
80034.01.216.01.22.04.599.6
100038.61.516.01.22.04.5108.3
120042.01.516.01.22.35.0112.7
140045.01.516.01.22.35.0115.7
160049.21.516.01.22.35.0118.9
180051.01.516.01.22.45.0121.9
200054.01.516.01.22.55.0125.1
220057.51.516.01.22.55.0128.6
250060.01.516.01.22.55.0131.1
300067.11.516.01.22.75.0138.6



Total Weight for Cable
(kg/km)
CopperAluminum
Insulation and PVC SheathPE SheathInsulation and PVC SheathPE Sheath
8243.07842.06755.06354.0
8860.08453.06994.06586.0
9755.09343.07288.06875.0
10759.010337.07721.07299.0
12370.011881.08477.07988.0
14192.013686.09207.08701.0
17149.016598.010825.010274.0
19379.018743.011939.011303.0
21475.020821.012795.012141.0
23595.022923.013675.013003.0
25787.025097.014627.013937.0
28002.027293.015602.014893.0
30160.029430.016520.015790.0
32093.032349.017593.016849.0
38565377761996519176


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:"Cable laying" cable cross-sectional area refers to the cable cross-sectional area, or refers to the copper core cross-sectional area
What kind of clothes do you want to do? General to high-speed sewing machine, the most important three-line lock machine, hot Taiwan, such as a suit to buy a pressure machine, workstations
Q:150,120,95,50,25,10,4 * 1.5,2 * 1.5 how much cable to use the heat shrink tube
Due to the circumstances of the question .. at any time questioned us
Q:1.2 meters below the road can use pvc tube wear armor cable?
Have to fight trumpet, mainly to protect the cable jacket is not scratched
Q:Power Cable Check Well b-type covers show what?
B-grade steel fiber concrete check covers are used for motor vehicle driving, parked urban roads, highways and parking lots C-grade steel fiber concrete check covers for slow lanes, residential quarters and sidewalks D-grade steel fiber concrete inspection covers for green belts and motor vehicles can not travel, parked lanes and venues
Q:What is the installation specification for the cable tray bracket?
In accordance with the requirements of the general requirements of the installation of the switch installation height is 1300mm, the socket is 300mm, air conditioning socket is 1800 ~ 2200mm; wall in accordance with the norms is not allowed to take the horizontal pipeline, so the conventional approach is vertical inside the floor of the pipe is near run.
Q:The difference between power cable and overhead cable
. the power cable occupies less. Generally buried in the soil or laying in the room, the channel, the tunnel, the line between the insulation distance is small, no tower, covers an area, basically does not occupy the ground space. The overhead cable is the opposite. . power cable reliability. Affected by climatic conditions and the surrounding environment, transmission performance is stable, high reliability. . the power cable has to ultra-high pressure, large capacity development of more favorable conditions, such as low temperature, superconducting power cables. . the power cable distribution capacitor larger. Overhead cable is the opposite . the power cable maintenance work less overhead cable is the opposite . the power cable electric shock is unlikely. The overhead cable is the opposite
Q:Power cable casing buried what are the requirements
2 direct laying cable way, should meet the following requirements: 1 cable should be laid in the trenches, and should be along the length of the cable on the next, next to the side of the shop with a thickness of not less than 100mm soft soil or sand 2 along the length of the cable should cover the width of not less than 50mm on both sides of the cable protection board, protective board should adopt concrete 3 urban cable buried in the laying, it is appropriate in the protection board laying eye-catching signs 4 in the suburbs or open areas, along the cable path of the line spacing of 100m, corner or joint parts, should be erected obvious signs or signs 5 when the use of cable through the corrugated pipe laying in the trenches, should be along the full length of the bellows casting thickness of not less than 100mm of concrete, the width should not be less than 50mm outside the tube, the cable can not armor 3 buried in the non-frozen soil area, the cable embedding depth should meet the following requirements: 1 cable to the basement of the basement structure, not less than 03m 2 cable skin to the ground depth, not less than 07m; when located in the carriageway or farmland, should be properly deepened, and should not be less than 10m 4 buried in the permafrost area, should be buried below the permafrost layer, when not buried can be buried in the soil drainage of dry frozen soil or backfill, but also take other measures to prevent damage to the cable The 5 Directly laying the cable, is strictly prohibited in the underground pipe is just above or below The minimum distance between cable and cable, pipe, road, structure, etc shall be in accordance with Table 535 Table 535 Permissible minimum distance between cable and cable, pipe, road, structure, etc (m)
Q:A sub-eight splitter, behind the link ONU equipment, which also need to add fiber patch panels, or can be directly connected?
Cable and 10kV power line parallel laying the minimum distance of 0.5 meters.
Q:Will the computer master, external DVD burner how external power supply, please click details. Thank you!
Regardless of multi-wire or single-core, as long as it is in line with national wire standards, and now the market is not the current market line 60% compliance. To select the regular products, national safety certification, safety standards, a good installation process and the standard of the wire, a local demand for electricity with the appropriate diameter. To ensure that you are comfortable with electricity,
Q:How to connect the power cable pre-branch connector
Pre-branch cable detection: a In addition to routine pressure test, it is necessary to increase the insulation resistance test, with a shake table can be completed in each branch after the completion of injection The table measures the insulation in the finished product After the pressure is also used to detect the insulation of the table to prevent the water cooling process in the branch of the water caused by short-circuit, the general AC voltage test can not detect, can only increase a set of table detection process B Core conduction detection, In each branch body should be tested with the trunk of the conduction test to prevent the production process due to improper operation caused by the branch and the trunk circuit

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range