CONDUCTOR XLPE INSULATED PVC SHEATHED POWER CABLE RATED VOLTAGE UP TO 35KV

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
30000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Introduction:

 

XLPE INSULATED POWER CABLE

COPPER(ALUMINMU)CONDUCTOR XLPE INSULATED PVC SHEATHED POWER CABLE RATED VOLTAGE UP TO 35KV

 Cross-linked polyethylene insulated power cable do not only has excellent electric, mechanical proper-ties,but also has powerful resistance against chemical corrosion,heat resistance and environmental stress resistance. Its structure is simple,the long period operating temperature is +90°C. It is convenient to use and can be laid with no restriction of different level.

1.standards

The Products are mainly complying with IEC 60502 standard,  also can be produced according to OEM requirements and others standars, Such as BS Standard, DIN standard, ASTM standard, ETC.

 

2. voltage

Voltage grade is up to 35KV,

 

3. construction

copper or aluminum conductor

copper tape sheild

XLPE insulated

steel wire or steel tape or copper tape armoured

PVC sheath

 

Specification:

 

TYPE

 VOLTAGE

No.of cores

0.6/1kV

6/6kV, 6/10kV

8.7/15kV, 12/20kV, 18/30kV

19/33kV, 26/35kV

Mm²

COPPER/XLPE/PVC

1

1.5~800

25~800

35~1200

50~1200

AL/XLPE/PVC

2.5~1000

25~1000

35~1200

50~1200

COPPER/XLPE/SWA (STA,AWA)/PVC

10~1000

25~1000

35~1200

50~1200

COPPER/XLPE/PVC

3

1.5~400

25~400

35~400

50~400

AL/XLPE/PVC

2.5~400

25~400

35~400

50~400

AOPPER/XLPE/AWA (STA)/PVC

4~400

25~400

35~400

50~400

 

CONDUCTOR XLPE INSULATED PVC SHEATHED POWER CABLE RATED VOLTAGE UP TO 35KV

CONDUCTOR XLPE INSULATED PVC SHEATHED POWER CABLE RATED VOLTAGE UP TO 35KV

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What does the cable (YJV-5 * 6) mean?
ZR-flame retardant Y-polyethylene J-crosslinked V-PVC sheathed YJV is copper core, YJLV is expressed as aluminum core, where L is aluminum. 22 indicates the type of armor armor, and 32. So the full name is: flame retardant copper conductor cross-linked polyethylene insulated PVC sheathed power cable 4 * 16 that there are a total of four copper wire, which each cross-sectional area of 16 square millimeters
Q:Calculate the control cable under what circumstances the cable terminal needs to be calculated
" Why should the closed wall or protective wall closed on the second side of the closed junction box? This need to understand if you do not add this closed junction box, what kind of harm Civil air defense project in the closed wall is divided into the clean area and the area of ​​the infected area, and the wire tube in the thread after the inside is a cavity, directly through the wall to communicate with the cleaning area and exposed areas, so wartime works outside the dyeing The poisonous air can penetrate into the clean area through the cavity inside the wire tube, which is harmful to the personnel inside the project And the installation of a sealed junction box, you can thread in the line after the box filled with sealing material to block the tube cavity connectivity This is why the electrical safety pipe in the air defense project must pass the closed wall or protect the closed wall when the two sides must be closed in the closed junction box reasons
Q:Will the two 16 square copper wire with what specifications of the trunking
If the network cable is shielded with the network no problem, in fact, the main problem is not interference, it touches on security issues, from the truth, the strong and weak electricity can not take a bridge, if you must go inside a bridge, to add metal partitions The
Q:What is the meaning of "cable tray: 200 * 100 middle strip" in electrical engineering
In addition to considering the security issues, there is no problem, you can use this, there is no impact on the charging situation, rest assured
Q:With a i3-2100 desktop computer about how much money. To have a separate graphics card. Give a configuration alone, no more than 4000
According to the total amount of household electricity to calculate the main line with how much, if the maximum load of more than 7 kilowatts, with 6 square BV or BVR line, no more than 4 square, branch kitchen socket with 2.. light line with .05-1.5 are Yes, air conditioning hang up 2.5 enough, Guiji take green 4 square
Q:Cable zc_y v22 what does it mean
No problem with the copper, the home is no problem as if you take a twisted pair as a telephone line KVV with BV material, the process is not much difference in the production...
Q:Engineering materials inspection, all types of cable wires should be issued a test report?
Is the aluminum core armored cable for outdoor high pressure conforming to the specification
Q:The UV lamp is fitted with ozone and no ozone difference
Clean the copper wire to be welded, and dip a little solder paste or rosin before welding.
Q:How high voltage armored power cable is grounded
When the armor leads directly to ground to buy the cable terminal, the manual has a specific production process
Q:What is the length of the wire that affects voltage and electricity
Can go if you do not trust to wear a pvc into the bridge on it

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range