Concentric overhead conducting wire JL/G1A JL/G1B Steel cored aluminum stranded wire

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
200 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Product properties:  

1. The long-term working temperature allowed by overhead conducting wires is 70°C;  

2. When there are large-span rare weather conditions and there is less ice coating occurring in heavy ice areas, maximum stress the lowest point of the conductor sag should not be more than 60% of instantaneous destructive power;

3. When the wires are connected, strands around the connecting pipe should not bulge, otherwise the strands of wires in operation will be unevenly stressed, after the joints are pressed, outlets of connecting pipe should be covered with moisture-proof paint to prevent corrosion; 

4. When the wires are installed, sag stress of all the wires at the same gear should be the same, and within the range permitted by the limited distances to the ground and exceeding the distance for protection of building, the conducting wire stress can be higher by 10-15% than normal tension.  Scope of application:  This product is applied to overhead power transmission and distribution lines.


Scope of application:

This product is applied to overhead power transmission and distribution lines.


Type and Specification:

New Type

Original type

Description

Specification No.

JL

LJ

Aluminum stranded wire

10--1500

JL/G1A  JL/G1B

LGJ

Steel cored aluminum stranded wire

16--1250

JL/G1AF  JL/G2AF

LGJF

Anti-corrosion steel cored aluminum   stranded wire

16--1250

JLHA1   JLHA2

LHAJ

Aluminum alloy stranded wire

16--1250

JLHA1/G1A  JLHA2/G1A

LHAGJ

Steel cored aluminum alloy stranded   wire

16--1120

JL/LHA1  JL/LHA2

LLHAGJ

Aluminum alloy cored aluminum stranded   wire

16--1400

JG1A  JG1B  JG2A  G3A

GJ

Steel stranded wire

6--63

JLB1A  JLB1B JLB2

LBGJ

Aluminum-clad steel stranded wire

4--200






Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Emergency cable T-box and cable distribution box of the information?
The incoming and outgoing wires are electrically connected together The potential is the same, which is suitable for tapping or branch wiring It is common practice to add the number of lines back to the number of times The three-branch cable splitter box, which has three equipotential bonding points on each phase, can be used as a second or two-in-one Cable distribution box contains U, V, W three-phase, three-phase circuit structure is the same, along the row together 2 High-level distribution box High-level distribution box containing switching equipment, both from the ordinary distribution box of the tap, branch, but also from the power supply circuit control, conversion and change the mode of operation The switch fence roughly divides the cable circuit into the inlet and outlet sides, and the potential on both sides can be different The switchgear itself has a larger volume, so the high-level distribution box size is relatively large, the height is generally 14 ~ 18m, the depth of about 09 ~ 10m, the length of the number of switching devices according to the number, M to 24 m The shape of the box is similar to that of an outdoor box transformer, and there are a number of active doors on the shell Some doors are designed for the operation of the switchgear Some doors are provided for the installation or maintenance of the cable connection device The
Q:Which has, know the power of the electrical, choose the cable formulas. And explain it
The audio line to use a shield of the special line, shielded cable and TV open to the road, the state is 1 to more than the signal line, the outer layer of metal mesh, with this line It will be disturbed.
Q:Is the power cable considered a fixed asset?
According to the total number of meters, such as where to where a total of how many kilometers (meters). Power system fixed assets asset management software - TU Teng fixed asset management software.
Q:Cable zc_y v22 what does it mean
No problem with the copper, the home is no problem as if you take a twisted pair as a telephone line KVV with BV material, the process is not much difference in the production...
Q:What is the interface between the power interface and the hard disk?
How can you pick up the computer, Internet cafes router connected to the tap, each tap has a lot of jacks, so you can pick up so many computers, you can carefully observe the Internet cafes, some iron box there are a lot of green In the flash is the tap
Q:Why does the sparrow stand on the wire without electric shock?
the network patch panel is now more mainstream network system patch panels, generally every 1U height can accommodate 24 8-core network port, back line, front jumper plug in addition, look at the Google Encyclopedia on the 110 patch panel instructions, found a little problem, that is 110 patch panel documents, but the picture is not 110 patch panels, that should be called Kelon, we also Called this thing for the VDF, it should be noted that the 110 system is AT & amp; T, that is, Lucent (Lucent) company's standards, and Kelon is the German Kelon (kelone) company's standard, not the same thing, Dragon frame is generally used in large-scale voice wiring system, and generally fixed for the wall, if placed in the standard cabinet will have to install the backplane, the Kelon frame steel frame fixed on the backplane The 110 patch panel is a standard 19-inch equipment, can be directly fixed in the standard 19-inch cabinet As the 19-inch standard cabinet has been widely used in the civilian areas, so Kelon is now less application, mainly in the use of operators these with a number of tattoo and fat ancient mix of full-chip cable is integrated wiring system in the most basic connector, the product range is also very much on the market, of course, there are many changes in the form On the use of network patch panels and 110 patch panels, Google Encyclopedia and the library have a detailed description, you can refer to
Q:What does the cable ZR-YJV22-4 * 16 mean?
Copper core flame retardant XLPE insulated PVC sheathed power cable, three core, 6 square
Q:How high voltage armored power cable is grounded
Insulated isolation of the double shield control cable is the outermost armor layer should be grounded at both ends, the inner shield one end of the ground, is conducive to the rapid release of induced current.
Q:Water and electricity installation drawings in the kz on behalf of what material of the threading tube
HDMI interface common in some new TV, which is called "digital high-definition multimedia interface", mainly for the transmission of high-quality, lossless digital audio and video signals to high-definition television, the maximum bandwidth of 5Gbps In addition, There is also an interface you need attention, this interface is called "DisplayPort", it can provide the same function with the HDMI interface, and can provide bandwidth up to 108Gb / s, much higher than the HDMI interface More importantly, DisplayPort is free Standard (HDMI charges), almost all of the personal computer manufacturers and graphics card manufacturers have expressed support for this interface
Q:Emergency power off after the computer can not open the machine, an open is a lot of words appear seconds limit, you can
Buried a few is based on the project to be set, as to how much diameter will be based on your plan to determine the cable, the national standard to protect the tube diameter at least 1.5 times the diameter of the cable through the cable. Embedded is to consider the size of long-term power supply, when the load increases, you can directly in the embedded casing to wear cables, so that one-time embedded well, not to re-dig cable cable buried cable, saving time and effort, but also to avoid the Damage to the original cable foundation and the road above the cable

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range