(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Which wire goes with which wire on the other side? (Foto)?
It's not just your oven that makes a difference, but the year your oven was manufactured in AND the country it was manufactured in that makes a difference. It was easy to identify your supply wires as Brown = live wire; Blue = return (neutral) wire; green/yellow = earth ground, and this is single phase wiring. There would be an orange wire for 3 phase... ...but the oven wiring conforms to a different standard of gray - white -red where red is possibly the ground line, while the other two are your live and return wires, with the gray likely to be the return wire....BUT...in some time periods, the red wire was the live wire. Your best bet is to test the oven wiring out with a multi-meter and look at what color of wire is connected to where. The earth ground should be connected to the oven's cabinetry; the live wire would be wired to the oven's internal fuse or circuit breaker, and then wired to the business end of the heater elements, timers, etc. The return wire would be connected to the other side of the elements and timers. Your most reliable way to address this is to consult a professional. That second link I posted has both old and new French wiring standards, and neither match your oven. And if your oven isn't manufactured in France, you have yet another level of wiring code to unscramble.
Q:2nd phone line with no black wire?
the wire you have is designed for 1 line only. Back in the day the yellow wire was used to carry ground because ground was necessary for old circuits. Ground is no longer needed so in order to get two lines you need at least a two pair wire (meaning four wires) you might have to run a new wire unfortunately or just keep that one and run another to separate jack.
Q:What is a black/yellow wire?
if you do not have a circuit tester then it is time to buy that $3.00 item === it is a little glow light that will be a dim light at 110volts and a brighter light at 220volts -- has two wires with metal ends and can help you with the disposal and wall sockets or other connections ... any hardware store has this tester. NOW ... we deal with the blk/yellow wire -- it is possible that it is a ground, or it is a hot wire or it could be to a GFIC [[ ground fault interrupter circuit ]] that is in the home panel -- OR -- who knows about the electrician that was the original wiring person --- most I have ever seen in wires to a disposal is two [2] wires a blk and a wht == this is a common mistake that most DIYers make .. they do not take the time to make full investigation and label wires as they take things apart .... get the tester as that is the cheapest way to solve also look at panel for the GFIC or call an electrician ,,,,,,,,, respectfully,,, XTX
Q:wiring for 1986 Monte Carlo radio?
1986 Chevrolet Monte Carlo Car Audio Wiring Guide Car Radio Battery Constant 12v+ Wire: Orange Car Radio Accessory Switched 12v+ Wire: Yellow Car Radio Ground Wire: Black Car Radio Illumination Wire: Gray Car Stereo Dimmer Wire: Light Brown Car Stereo Antenna Trigger Wire: Pink Car Stereo Amp Trigger Wire: N/A Car Stereo Amplifier Location: N/A Car Audio Front Speakers Size: 3 1/2″ Car Audio Front Speakers Location: Dash Left Front Speaker Positive Wire (+): Tan Left Front Speaker Negative Wire (-): Gray Right Front Speaker Positive Wire (+): Light Green Right Front Speaker Negative Wire (-): Dark Green Car Audio Rear Speakers Size: 4″ x 10″ Car Audio Rear Speakers Location: Rear Deck Left Rear Speaker Positive Wire (+): Brown Left Rear Speaker Negative Wire (-): Yellow Right Rear Speaker Positive Wire (+): Dark Blue Right Rear Speaker Negative Wire (-): Light Blue
Q:Wiring Stereo In VW Polo 98?
When you wired it did you butcher the wires or use a wiring harness? With the wiring harness, everything is labeled and color coded. Match colors to the kenwood wiring harness, splice or use butt connectors, plug harness into factory harness and player, attach antenna wire and you're done! If you did butcher the wires and left enough wire, repair the harness and buy a harness kit at your local sound shop, really cheap too! Good luck!
Q:2000 chevy EGR wiring?
Connector view for the GM linear EGR valve are as follows: Pin# A=gray/w black wire,Pin# B=solid black wire,Pin# C=brown/w white wire,Pin# D=brown/w white wire(see note) and Pin# E=solid red wire! NOTE since pin C+D have the same color wire the correct wire must be identified by checking the voltage with the KOEO (key on engine off) the right brown/w white wire should have a 5volt reference voltage with the key on engine off! Hope this helps.
Q:orange wire from old stereo of Chevy suburban,what wire do i hook it up to on a custom stereo?
each cellular has DNA and that is consisted of two strands tightly woven around one yet another. the element that prevents the two strands from breaking aside is talked approximately as a telomeric cap (this is random nucleotide sequences talked approximately as nonsense codons. Codon is a three sequence of nucleotides that codes for amino acids eg. CUU is a amino acid talked approximately as proline . A nonsense codon is one that doesnt code for any amino acid production) each time your cells divide a small sequence is lost there with the aid of reducing the stability of the cellular's DNA (in layman's words). this might ultimately lead do maximum of Ur cells' DNA starting to be risky. and in many cases while a mistake happens in DNA the cellular will carry out automobile cytolysis (cellular suicide) to sidestep issues. So once you're previous maximum of ur cells telomeric caps would be low and that they are companies to die while they warfare to divide.. Whats incredibly exciting approximately this thought is the impact it has on evolution (because of the fact this occurs on the two meiotic besides as mitotic divisions. meaning that a species grows previous too in the previous it mutates.. yet thats a diverse tale)
Q:Connecting speaker wire?
You twist together the white and black together and the red and green to together, but you have to make sure this is done on both ends of the wire, I suppose you are taking about CL-4 wire for long runs inside walls? Actually that kind of speaker wire is suppose to be terminated at the wall with an in wall jack and then regular speaker wire is run from there to the speakers but you can really do it other ways, it just looks neater and you run less chance of damaging the wire.
Q:how to wire an emergency residential boiler switch?
Hello there George, It has become common over the past few years that non-residential boilers are wired with EPO (emergency, power off) switches just outside each door to the boiler room. This is similar to having fire alarm pull boxes by the exits. I do not know of any jurisdiction that requires it for a residence. On occassion I've seen the 24 volt circuit for the thermostat being switched, which is a bit sketchy. Normally the 120 volt circuit for the controller is switched. The switches used are of the pushbutton type.
Q:Photocontrol on a outside light wiring help?
no offence and no help but WHY did you not take a note of the connections as others have been told to do,in reality it makes no difference what colour of wiring goes where it is what the wire does that is important in other words if you swap the brown and blue at a light it will still work can you not remember what the connections were at onset of job.Best plan of action when dealing with electrics is if you do not know what to do do not do it

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range