Product Description:

Description Of CMAX Pump use 75KW Inverter Frequency

CMAX Pump use 75KW Inverter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse

 

Features Of CMAX Pump use 75KW Inverter Frequency

1).Adopts 16 bit microprocessor, sine wave PWM control

2).Automatic torque ascension and automatic sliding compensation function

3).Output frequency 0.1-400 Hz

4).8 period of speed setting and 7 period can be running the program

5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment

6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration

7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA

8).The built-in serial communication interface RS-485(baud rate can reach 38400)

9).Save energy running and automatic voltage stabilizing section function (AVR)

10).Adjustable V/F curve Acceleration and automatic and deceleration function

11).Simple vector control and built-in PID control, and the simple positioning function

12).Sleep/wake up function and zero velocity keep function

 

Structure Of CMAX Pump use 75KW Inverter Frequency

CMAX Pump use 75KW Inverter Frequency

Application Of CMAX Pump use 75KW Inverter Frequency

★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

★Plastic: extruder, hauling machine, decorating machine, etc.

★Pharmacy: mixer, roaster, etc.

★Woodworking: engraving machine, sander, veneer peeling lathe, etc.

★Papermaking: single type papermaking machine, etc.

★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

★Printing: cloth-washing machine, dye vat, etc.

★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

★Fan and pump: kinds of fans, blowers and pumps

CMAX Pump use 75KW Inverter Frequency

 

Performance Of CMAX Pump use 75KW Inverter Frequency

Item Specification
Input Rated voltage T4 series: Three phase 380v, ±15%
Frequency  S/T2 series: Three/single phase 220V, ±15%
50/60Hz  ±5%
Output Voltage T4 series: Three phase 0-380V
Frequency S/T2 series: Three phase 0~220v
0-400Hz
Overload ability 150% rated current for 30s; 180% rated current for 1s;
Dissipation Cooling type  Forced Cooling
Temperature protection  Heatsink temperature >85℃ trip protection against overheat
Fan control Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work
Control Control mode Open-loop vector control, V/F control
Performance Start torque Open-loop vector control: 0.5Hz 180%; 
VF control: 0.5Hz 150%
Speed range Open-loop vector control:1:150; 
VF control:1:100
Speed control precision Open-loop vector control: ±0.2%; 
VF control:±0.5%
Function Channel of operation command Keyboard control,terminal control,communication control
Start mode Direct start, DC injection braking before start, speed tracking before start
DC injection braking Start DC injection braking, stop DC injection braking
Dynamic braking Built-in braking unit
Frequency source choice Keyboard digital frequency setting, analog AVI setting
PID control setting, telecommunications setting
Frequency resolution Keypad setting:0.01Hz; Analog setting: 0.1%
Carrier frequency 1Khz~12Khz,
Acc/Dec time 0.1~6000.0s or 0.01~600.00s
Signal Analog input AVI:0~10V
ACI:4~20mA 
Keyboard potentiometer input: 0~10V
Analog output AFM:0~10V or 0~20mA, Select through JP1 jumper
Digital input A total of 28 kinds of function could be selected from S0 ~S5.
Digital output 1 channel open collector output(MO1-MCM)
1 channel relay output( TA-TC normally open, TB-TC normally closed;
Communication Port Communication protocol Based on RS485 hardware, support standard MODBUS protocol. 
Display Functions Four digital tube display Can monitor the operation state of frequency inverter flexibly and conveniently.
Installation                                 Humidity Less than 90%RH
condensation
Vibration Less than0.6G
Elevation 0~1000m, reduce the rated specification 10% when lift 1000m for each. 
Storage temperature -20~60℃          
Structure Defend degree IP20

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Do you need to rectify before switching?
Need to rectify. The inverter is actually an inverter, which first turns the alternating current into direct current, then switches the DC power with the electronic components, changes to alternating current, and the general-purpose inverter is equipped with a thyristor and an adjustable frequency The frequency is adjustable in a certain range, and it is used to control the number of revolutions of the motor, so that the number of revolutions can be adjusted within a certain range.The frequency converter is widely used in the speed regulation of AC motor. Technology development direction, with the development of power electronics technology, AC frequency conversion technology from theory to practice gradually mature. Inverter not only smooth speed, large range, high efficiency, start current is small, smooth operation, and energy saving effect is obvious. Therefore, the exchange frequency control has gradually replaced the traditional traditional slip speed, variable speed control, DC speed control system, more and more widely used in metallurgy, textile, printing and dyeing, smoke machine production lines and buildings, Water supply and other fields. Generally divided into rectifier circuit, flat wave circuit, control circuit, inverter circuit, and so on several major parts.
Q:Laptop power adapter problem
First, that is called the transformer, not called the charger, not with you bite the word, but you according to the charger to Taobao search, basically one hundred percent are not found.
Q:HP laptop power adapter how to open
HP notebook power adapter for the full size of the design, you can follow the following steps to dismantle: 1, notebook computer power adapter for the injection molding package or with a strong adhesive glue, without any screws, so generally only with violence to crack. However, as long as the method properly, after the dismantling of the power adapter can be restored to the original, do not carefully observe almost no traces of open. 2, the power adapter on the side of the side of the white paper, with an electric knife edge along the power adapter between the gap between the cover, and then hit the electric knife with a hammer, so that the electric knife from the adapter between the upper and lower cover go with. In the different positions of the gap between the upper and lower covers of the adapter, use the tip of the electric knife to be scratched along the gap. When the upper and lower covers are first split, the depth of the tool is deep and then the upper and lower covers of the adapter are separated. 3, then open the shell of the power adapter, you can see the adapter circuit outside the package with a copper shield, with a knife to cut the shielding tape on the tape, and then use the soldering iron shield and the internal circuit board connected to the two Solder joints, you can remove the shield. 4, between the shield and the circuit board is also separated by a layer of thick plastic film, and then cut off the knife after the United States, you can see the circuit board "Lushan true"
Q:What is the laptop adapter
3, classification: according to the use of points (AC, such as home, office use AC are called AC; DC, such as the car, the aircraft are used DC are called DC); by the output voltage current (12V series, ASUS more commonly used, such as ASUS 12V3A; 15V series, TOSHIBA more commonly used, such as TOSHIBA 15V3A, 15V4A, 15V5A; 16V series, SONY, IBM more commonly used, such as SONY 16V4A, IBM 16V4.5A; Series, HP, such as HP 18.5V3.5A; 19V series, such as ACER 19V3.42A, TOSHIBA 19V3.42A; 19.5V series, such as DELL 19.5V3.34A, SONY 19.5V4.1A; 20V series, such as DELL 203.5A , LENOVO 20V3.25A; 24V series, such as APPLE 24V1.875A; 9.5V-24V series, such as Acharger ALS-185A35C).
Q:What is the frequency of `30 points
frequency conversion By changing the AC frequency of the way to achieve AC power control technology is called frequency conversion technology
Q:If it is 8-pole variable frequency motor, enter the motor nameplate parameters in the inverter input for the 4 pole can?
According to the number of revolutions N = 60 * f (frequency) / p (pole pairs) can calculate the motor is a few poles. If the motor is 8 pole is not recommended in the inverter set to 4. will certainly affect the control accuracy.
Q:Is the laptop power adapter AC and DC?
Notebook power adapter is not AC and DC. Power adapter is a small portable electronic equipment and electrical and electronic power supply conversion equipment, generally by the shell, power transformers and rectifier circuit, the working power for the exchange (China AC standard AC 220V), according to its output Types can be divided into AC (AC) output type and DC (DC) output type. General notebook power adapter are DC output, is the exchange of DC conversion equipment.
Q:What is the laptop power adapter? Is it the battery?
so that the book can be normal operation, or else you think the notebook is 220V Is the voltage at work?
Q:How to disassemble the notebook power adapter
HP laptop power adapter for the whole design of small sealed, you can follow the following steps to dismantle: 1, laptop power adapter for the injection molding package or with a strong adhesive glue, without any screws, so generally only with violence Cracked. However, as long as the method properly, after the dismantling of the power adapter can be restored to the original, do not carefully observe almost no traces of open.
Q:Speed of 3000 r / min three-phase motor how to change its speed
Only the frequency converter to achieve the purpose of speed, because the rated voltage and frequency, the three-phase motor speed is determined by the motor within the pole pairs of pole number, but the frequency down, the speed decreases, plus a frequency converter, Can achieve the purpose of stepless speed regulation. The speed is calculated as: speed = (50 Hz * 60 seconds) / (number of poles / 2), the result is synchronous speed, the general asynchronous motor slightly lower than the synchronous speed. There is a change for the electromagnetic speed of the motor, but also to achieve the purpose of stepless speed regulation. If you have a fixed number of revolutions, you can consider buying a reducer and motor integrated, such as cycloid reducer, can also be installed between the motor and equipment reducer to achieve the purpose of deceleration.
We are a professional inverter manufacturer integrating R&D, production and sales. With an experienced R&D and production team and sophisticated production lines, our company has become a domestic first-class inverter manufacturer by virtue of advanced technology, excellent quality, scientific management and perfect service

1. Manufacturer Overview

Location Zibo, China
Year Established 2004
Annual Output Value Below US$1 Million
Main Markets Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia
Company Certifications CE;ISO

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Qingdao
Export Percentage 1% - 10%
No.of Employees in Trade Department 500-999 People
Language Spoken: English; Chinese
b)Factory Information  
Factory Size: Above 50,000 square meters
No. of Production Lines Above 8
Contract Manufacturing
Product Price Range High; Average