Product Description:



Design
Horizontal, high-pressure barrel-type pump with radial impellers,  single- and double-entry, multistage, with flanges / weld end nozzles to DIN and ANSI.                                        
Applications
Handling of feed water and condensate in power stations and industrial  facilities, generation of pressurized water for bark peeling machines and descaling equipment.


 

Overview of technical data

Type of installation                                                                         Long- coupled                    
Type of bearing                                                                         Plain bearings                    
Drive frequency                                                                         50 Hz / 60 Hz                    
Maximum speed of rotation                                                                         6. 750                         1/min                    
Maximum flow rate                                                                         1. 278                         m³/h                    
Maximum discharge-side pressure                                                                         400                         bar                    
No. of impeller entries                                                                         Single / Double entry                    
Casing material                                                                         Carbon steel; Chrome steel                    
Suction characteristics                                                                         Non- priming                    
Drive voltage                                                                         Low voltage, high voltage                    
eClass assignment                                                                         36410000; 36410101;36410100                    
Pull-out design                                                                         Yes                    
Other impeller types                                                                         Closed / Radial                    
Barrel casing                                                                         Yes                    
Pump set location                                                                         Dry installed                    
Type of suction casing                                                                         Annular casing                    
Max. permissible fluid temperature                                                                         200                         °C                    
Type of discharge casing                                                                         Annular casing                    
Type of first impeller                                                                         Single entry                    
Main applications                                                                         Energy; Industry and process engineering                    
Type of installation                                                                         Stationary                    
Type of connection                                                                         Flange, weld ends                    
Type of lubrication                                                                         Grease / Oil / Pressurized oil lubrication                    
Type of drive                                                                         Electric motor, turbine                    
Installation position                                                                         Horizontal                    
Maximum suction pressure                                                                         30                         bar                    
Type of coupling                                                                         Geared variable speed coupling; Gear;Variable speed coupling;Direct                    
Shaft seal type                                                                         Mechanical seal                    
Maximum head                                                                         4. 000,00                         m                    
Maximum rated pressure (discharge)                                                                         PN160; PN250; PN320; PN400                    
Type of stage casing                                                                         Stage casing with diffuser                    
Nozzle position                                                                         Variable                    
Casing partition                                                                         Radially split

Design
Horizontal, high-pressure barrel-type pump with radial impellers,                                                            single- and double-entry, multistage, with flanges / weld end nozzles to DIN and ANSI.                                        
Applications
Handling of feed water and condensate in power stations and industrial                                                       facilities, generation of pressurized water for bark peeling machines and descaling equipment.

 


Overview of technical data

Type of installation                                                                         Long- coupled                    
Type of bearing                                                                         Plain bearings                    
Drive frequency                                                                         50 Hz / 60 Hz                    
Maximum speed of rotation                                                                         6. 750                         1/min                    
Maximum flow rate                                                                         1. 278                         m³/h                    
Maximum discharge-side pressure                                                                         400                         bar                    
No. of impeller entries                                                                         Single / Double entry                    
Casing material                                                                         Carbon steel; Chrome steel                    
Suction characteristics                                                                         Non- priming                    
Drive voltage                                                                         Low voltage, high voltage                    
eClass assignment                                                                         36410000; 36410101;36410100                    
Pull-out design                                                                         Yes                    
Other impeller types                                                                         Closed / Radial                    
Barrel casing                                                                         Yes                    
Pump set location                                                                         Dry installed                    
Type of suction casing                                                                         Annular casing                    
Max. permissible fluid temperature                                                                         200                         °C                    
Type of discharge casing                                                                         Annular casing                    
Type of first impeller                                                                         Single entry                    
Main applications                                                                         Energy; Industry and process engineering                    
Type of installation                                                                         Stationary                    
Type of connection                                                                         Flange, weld ends                    
Type of lubrication                                                                         Grease / Oil / Pressurized oil lubrication                    
Type of drive                                                                         Electric motor, turbine                    
Installation position                                                                         Horizontal                    
Maximum suction pressure                                                                         30                         bar                    
Type of coupling                                                                         Geared variable speed coupling; Gear;Variable speed coupling;Direct                    
Shaft seal type                                                                         Mechanical seal                    
Maximum head                                                                         4. 000,00                         m                    
Maximum rated pressure (discharge)                                                                         PN160; PN250; PN320; PN400                    
Type of stage casing                                                                         Stage casing with diffuser                    
Nozzle position                                                                         Variable                    
Casing partition                                                                         Radially split

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Please tell me how to use the multimeter to measure those aspects when the working circuit of construction machinery is out of order
Construction machinery movement, the executing agencies have cylinder action (hydraulic), motor and so on. Control parts are mostly weak current, drive parts and actuators are strong electricity (such as motor). When work is out of order. Generally check the power supply, the boot after the drive part of the power.
Q:Who builds expanded metal machinery?
Why don't you try typing expanded metal machinery on yahoo.
Q:Do old-fashioned TV sets contain lenses in any part of their machinery?
By old-fashioned are you referring to the cathode ray tube? If so it does not use lenses in reference to being able to focus the picture. Websearch cathode ray tub how it works and you'll get a ton of links and illustrations.
Q:Building and construction machinery?
If you purchase new equipment the new equipment will come with a warranty.You would have to take an expert mechanic with you when you look at used equipment.You would also have to know your district's laws.Some crane types might be illegal in your district.If someone tries to sell you an illegal machine you would have to take the appropriate legal measures.
Q:Where can I buy ammunition making machinery?
You're going to need to do more than pool money with friends to set up an ammunition factory. You'll need a building, several tens of thousands of dollars, and a lot of permits from federal, state, and local government. Even if you pulled off the setup, you would not be able to purchase raw materials in sufficient quantities to be able to make it cost-effective.
Q:What is the definition of computer science given by the Association of Computing Machinery?
Computer Science Definition
Q:How to write the summer practice report of construction machinery?
< > lasted nearly a month of the end of the internship, the internship, the first line to really reach the machinery manufacturing industry, understand the development condition of our country manufacturing industry is also rough further understanding of the development trend of mechanical manufacturing. In the new century, science and technology will develop faster, faster and more closely the integration in various fields, and the development direction of all this will greatly expand the mechanical manufacturing industry.
Q:machinery used for making apple and various juices and its machinery cost?
I just searched for industrial juicer which also led to commercial juicers. One that came up was the Uniworld (UJC-750) that does 50 gallons an hour for around $700. I didn't look that deep into the links because it's not for me, but I'd guess you can find even bigger equipment in some of those places.
Q:Registration process of a construction machinery maintenance plant in Tangshan? What information should be prepared and which departments should be handled?
Sign the rental contract, but also to the tax bureau to buy stamp tax, annual rental rate of 1/1000 of the purchase, such as your annual rent is 10 thousand yuan, tax 10 yuan would buy, attached to the rent contract home, followed by those who need to use the rent contract in place, need to copy the contract a post stamp tax.
Q:What is the difference between auxiliary machinery and ancilliary machineries?
Auxiliary would be like a pump or power generator, ancilliary would be more like drill press in the mechanics shop, one is needed to service the other, or another example would be the automatic potato peeler in the mess would be ancilliary

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range