Chemical Pump for Hot Temperature Food Oil

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

                   Chemical Pump for Hot Temperature Food Oil

1.Structure of Chemical Pump Description

Chemical Pumpis used in transporting high temperature liquid without solid particles.The temperature is not higher than 370 °C.This pump is proper in machinery manufacturing, food processing, medicine making and the circling system for oil supplying of the hot oil boiler, the circling system of the heating installation.

 

2.Main Features of the Chemical Pump

•Reached JB/JQ20104-1998 standards
•Oil temperature can reach to 200degre. 
•SS304 material 
•Good quality

3.Chemical Pump images

Chemical Pump for Hot Temperature Food Oil

 

4.Chemical Pump Specification

 

Chemical Pump for Hot Temperature Food Oil 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What's the difference between a concrete pump and a concrete pump truck?
Concrete pump and concrete pump truck are concrete conveying machinery, use the same, but the former need to transport and car towing need additional support pipeline, the locomotive body and arm extends freely, without pipeline, hundreds of thousands of millions of the former, the latter
Q:What is the series of pumps? What's the difference between a unipolar and a multistage?
You're talking about a centrifugal pump. His series says the number of slices of the impeller (excluding the wheel, that is, the wheel)
Q:Brief description of centrifugal pump on / off operation
Two, centrifugal pump start(1) the pump entrance valve fully open, start motor, outlet valve fully closed, fully check operation of pump.(2) when the pump outlet pressure is higher than the operation pressure, the outlet valve is gradually opened to control the flow and pressure of the pump.(3) check whether the motor current is within the rated value, such as the pump in the rated flow operation, and the motor overload should stop the pump inspection.
Q:What is a vacuum pump for?
Aquaculture, screen printing machine, photographic plate machine, injection molding machine, automatic feeding machine, paper transport...
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
(1) the pellet dose in the safety standard of the infusion pump refers to the amount of liquid that is transported to the patient in a short period of time(two) pill dose limit is mainly to control the risk of accidental pill dosage. Especially after the mandatory requirements of pipe blockage in the elastic pipe storage liquid limit amount of agglomeration and the limitation of these methods to release pill dose.
Q:What are the constant pressure pumps?
CatalogBooster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principlefunctionMechanical installationMechanical selection of booster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principle
Q:What kind of motor does the hydraulic pump need?
First count the flow: Q=dn L / minD displacement / revN RPM / minThen calculate the actual power: N=QP/ (60K) kwQ flow L / minP MPa MPaK total efficiency (usually 0.85)
Q:Know flow and lift how to calculate the pump power?
The pump power (kw) ={9.61* flow (cubic meters per second) * head (m)}/.Where ETA is device efficiency, including mechanical, electrical loss and other factors, generally between 55%~80%. The smaller the pump, the lower the efficiency.
Q:Why do we need to stop the pump?
And the pump at the start, if the valve opening pump, then the pump outlet pressure (head) is very small, so the pump flow will be great, the pump power is very large, causing the start-up current is very large. In addition, the starting current of the motor itself is also very large. These two factors add up to the possibility of overloading the motor, resulting in failure to start or even burn the motor.
Q:What is the nominal pressure of the hydraulic pump and hydraulic motor?
Rated flow refers to the flow under the rated speed and rated pressure input to the motor.Due to leakage loss, the actual flow of the input motor must be greater than its theoretical flow. Actual flow of motor (i.e. inlet flow) leakage flow = theoretical flow of the motor.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range