Cheaper Price Electrical Wire/Cable in China

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
50000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Place of Origin:

Zhejiang, China (Mainland)

Brand Name:

cnbm

Model Number:

VV YJV VV22 YJV22 VV32 YJV32 VV62 YJV62 VV72 YJV72 YJLW02 YJLW03 KVV

Insulation Material:

PVC or XLPE

Type:

Low,Medium and High Voltage

Application:

s electric power distribution networks or industrial installations

Conductor Material:

Copper or Aluminium

Jacket:

PVC or PE

Filler:

Non-hygroscopic Polypropylene(PP)

Binder Tape:

Non-woven fabric

Metallic Armour 1:

Galvanized Stainless Steel Tape Armour(STA)

Metallic Armour 2:

Galvanized Stainless Steel Wire Armour(SWA)

Metallic Armour 3:

Non-magnetic Steel Tape Armour(only for single core)

Metallic Armour 4:

Aluminium Wire



Packaging & Delivery

Packaging Details:wooden drum; iron-wooden drum or steel drum
Delivery Detail:Depending on the quantity

Specifications

2015 new product electric power cable 
1 Conductor:Copper or Aluminium 
2 Insulation:PVC or XLPE 
3 Voltage:Low/Medium/High Vol

2015 new product electric power  cable  

Technical Parameters of our Power Cable 

1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890

2). Detailed description or construction:

    * Conductor: compacted or uncompacted copper or aluminium

    * Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)

    * Filler: Polypropylene filament with lapped binding tape

    * Binder: Binding tape

    * Inner sheath: Polyvinyl chloride (PVC)

    * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)

    *Sheath: Polyvinyl chloride (PVC)

3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:

    U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV

4). Voltage:

     0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV

    In the voltage designation of cables U0/U(Um):

        * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

        * U is the rated power frequency voltage between conductors for which the cable is designed;

        * Um is the maximum value of the "highest system voltage" for which the equipment maybe used.

5). Application:

     For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.

6). Marking: According to the customers' requirements

Cheaper Price  Electrical Wire/Cable in China

Cheaper Price  Electrical Wire/Cable in China

Cheaper Price  Electrical Wire/Cable in China

Cheaper Price  Electrical Wire/Cable in China

Cheaper Price  Electrical Wire/Cable in China

Cheaper Price  Electrical Wire/Cable in China

Cheaper Price  Electrical Wire/Cable in China

FAQ

·         Can we make an OEM order?

o    We can offer or supply goods as customers' requirements.

·         How can I get some samples? Free or not?

o    We can send some normal samples, absolutely free.

·         How does your factory do regarding quality control?

o    "Quality is priority." We always attach great importance to quality controlling from the very beginning to the very end. Our factory has gained ISO9001 , SGS authentication, CE for Europe, etc.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What does the cable (YJV-5 * 6) mean?
ZR-YJV22-4 * 16 is ZR armored flame retardant power cable, YJV22 copper core PVC insulated steel tape armored PVC sheathed power cable, 4 * 16 is 4 core 16 (mm2) section.
Q:What is the difference between VV22 and VV62?
Cross-linked power cable heating the main reason there are . the choice of continuous allowable current is less than the load of the maximum continuous current power cable; . the power cable in the implementation of the cable for cold contact, the use of crimping pliers die too large, leading to copper . the air switch input and output and cable copper nose connection, the choice of non-standard flat gasket or no spring gasket; . the air switch input and output side of the cable and cable core crimp is not solid and reliable; When the cable is connected to a strand, the air switch bolts are not tightened. . high-power UPS running, the filter cabinet is not put, n harmonic effects of cable overload, neutral overload, serious lead to cable breakdown, and a fire hazard. . the power cable along the building facade iron cabinet box laying, the surrounding environment is not ventilated, poor heat dissipation. Select the power cable should consider the following factors: . the rated voltage of the cable is greater than or equal to the rated power supply system power supply system; . the cable can continue to allow the current to be equal to or greater than the maximum load current load; . Power supply system short-circuit stability requirements; . according to the length of the cable to determine whether the voltage drop to meet the requirements; . the end of the line minimum short-circuit current should be able to protect the device reliable action. . a high degree of breakdown strength; . low dielectric loss; . a very high insulation resistance; . excellent resistance to discharge performance; . with a certain degree of flexibility and mechanical strength; . long-term stability of insulation.
Q:110 voice patch panel directly to the telephone line can be connected to it
sure. Take the ground pipe is to be from the floor under the brick. But the late completion of the drawing to be accurate, so that the next time to repair the line can not find the location. Want to answer to help you.
Q:A sub-eight splitter, behind the link ONU equipment, which also need to add fiber patch panels, or can be directly connected?
Cabinets Half Week + Line (Horizontal + Vertical) + End Range Cabinets Half Week Long or Longer to Equipment Reserve + Quota Total Length * 2.5%
Q:Where the computer can be a bare chassis. Which hardware inside the framework
It is best not to use this, because you have no way to test the signal line. There are special 10 line 8 line terminal telephone switch patch panel
Q:1omoons / days sensitive quad-core network set-top boxes can be used on old-fashioned televisions.
Pipe protection cable to wear metal hose, metal hose and galvanized pipe to use metal lock connection, the connection can not pull the light pull on the line. If there is no metal hose or no metal lock, in the pipe when the pipe toward the cable to the appropriate bending, preferably in the mouth of the cushion cable skin, and then use the electrical adhesive tape sticky, sticky. After the nozzle cut with a polisher smooth grinding, the provincial scratch cable.
Q:What is the length of the wire that affects voltage and electricity
When the cable is laid on the multi-layer bracket, the cables are arranged from top to bottom, the first layer is the high voltage cable, followed by the low voltage power cable. The control cable is placed on the lower part of the power cable. At the bottom of the instrument cable, when the low voltage power cable With the instrument cable in the same layer of laying, should be added partition isolation. Computer communication coaxial cable, full length are required to shield the use of closed trunking.
Q:Wire and cable manufacturing process (to be detailed)?
Copper core per square of the safe current (continuous use) for the 2.5A, intermittent use of 4A, according to the power count 550W-880W.
Q:Copper core power cable laying cable sets what fixed
BTS is 2G base station, a wireless network consists of N BTS and several BSC, each BTS need to access the BSC through the transmission network. 2G base station transmission interface is mostly 2M interface. SDH (Synchronous Digital System), is a technical system developed by ITU, is a transmission technology. SDH line side (that is, out of the cable) is 155M, 622M, 2.5G, 10G optical interface. Branch side (then business network equipment, including base stations) are more than 2M, FE, GE also has 155M optical interface. DDF and ODF are patch panels, DDF digital patch panels, ODF fiber patch panels. SDH line side of the ODF frame, is received on the outgoing cable, DDF frame service network equipment, in the base station is then BTS. Set the patch panel is mainly for easy maintenance, you can label on the patch panel, each interface business type is very clear. The communication system diagram in the base station is this: BTS - DDF - SDH - ODF - another bureau.
Q:Wire inside the two lines, red and black, black line is the line of fire or zero line ah?
If you buried the VGA line core has more than 7 (set the exclusion of the moxibustion smoked smoked ship to remove the shield), you can. VGA head is 5 to 10 feet welded together to do the public, red, green, blue shielded wire twisted together to receive the public ground: ..3 feet connected red, green, blue core; ; 14 white lines; outer shield pressure to the shell. (At least two) at both ends to pick out the audio line (left and right channels), shield to do the public, to access the audio 3.5 straight plug. If only one rich, on the channel to listen to listen to mona channel it

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range