Ceramic Fiber Mat Thermal Resistance

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

ST Type: 1260 Celsius;
HP Type: 1260 Celsius;
HAA Type: 1360 Celsius;
HZ Type:1430 Celsius;
COM Type: 1100 Celsius.

Characteristics:

Low thermal conductivity & low heat storage

Excellent thermal stability & thermal shock resistance.

Excellent erosion resistance

Excessent heat insulation,fire proofing and processing function

                       

Technical Parameters:

Item  Code

COM

ST

HP

HAA

HZ

Specification Tem(Celsius)

1100

1260

1260

1360

1430

Working Teem(Celsius)

<1000

1050

1100

1200

1350

Color

white

white

white

white

white

Dcnsity(kg/m3)

96
128

96
128

96
128

128
160

128
160

Rate of liner(%)(24h,Density 128kg/m3)

-4
(1000C)

-3
(1000C)

-3
(1100C)

-3
(1250C)

-3
(1350C)

Rate of thermal conductivity(w/m.k) (Density128kg/m3)

0.09(400C)
0.176(800C)

0.09(400C)
0.176(800C)

0.09(400C)
0.176(800C)
0.22(1000C)

0.132(600C)
0.22(1000C)

0.76(600C)
0.22(1000C)

Tensile strength(Mpa)
(Density128kg/m3)

0.08-0.12

0.08-0.12

0.08-0.12

0.08-0.12

0.08-0.12

Chemical composition
(%)

AL2O3

44

46

47--49

52-55

39-40

AL203+SIO2

96

97

99

99

-

AL2O3+SIO2+Zro2

-

-

-

-

99

Zro2

-

-

-

-

15-17

Fe2O3

<1.2

<1.0

0.2

0.2

0.2

Na2O+K2O

≤0.5

≤0.5

0.2

0.2

0.2

Size(mm)

Specification7200*610*10-50mm; OEM OFFERED

   

Why choose us:                                                                                                                                1, Manufacture price (8 years manufacture and export experiences)                                            

2, Good made in-house, so to control stable quality & on-time delivery.

3, Formed the Full Products Range

4, Factory close to sea port to save cost

5, ISO 9001:2008 Quality Management system & Company's integrated working system

6, Two Sales Offices: In both headquarter & Guangzhou to assure convenient services for customers.




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:what is the fireproofing material of engine room? who knows it ?
1. The new type fire retardant coating in fire retardant coating, the expanded vermiculite, expanded perlite heat insulation material and cenosphere adiabatic powder, etc. These inorganic component, is a major part of the thick coating type of fireproof coating, and they also are the major factor affecting the level of performance of fireproof coatings. The fireproofing thermal insulation properties of fireproof coating, is mainly determined by the fire back surface temperature of this factor, but also related to the fire endurance. If it reaches the same temperature for a longer time, it shows that it's fireproof thermal insulation is better, and the fire endurance therefore is higher. 2. The new fireproof board new fireproof board now is welcomed by the people and the important factor is its environmental protection, and with the increasing high-rise buildings, the fire protection requirements and strength requirements are also rising, it is a big challenge for the performance and standard of the fireproof board.. Now fireproof board is mainly used siliceous material or calcareous materials, and then mixed with the fiber material, lightweight aggregate, adhesives and chemical additives, it is not only be fireproofing, but also improve their thermal insulation performance, and light weight, good carrying capacity, good durability, no aging problem, more importantly, it is good in environmental protection.
Q:What materials is silicious thermal insulation board made of?
Refractories that contain more than 93% of the monox are acidic refractory materials which include ordinary silica brick, high-density and high-purity silica brick, silica brick that contains chromium, fused quartz products, unburned brick and siliceous ramming materials. It has good softening temperature under a fixed load and can resist corrosion of acid slag, but will have chemical reaction with alkaline slag. Silicious refractory of industrial value mainly is crystalline quartz, such as α and β quartz, tridymite and cristobalite.
Q:what is the specs of thermal insulation refractory slab ?
thermal insulation refractory slab features wear proof, heat resistance, impact resistance, acid or alkali resistance, smoke resiatnce, fire proofing,fungi proofing, mould proof,anti-static. fireproof panel is generally used for countertops, tabletops, walls, cabinets, office furniture, wall hung cupboard. Common Specifications: 2135mm × 915mm, 2440mm × 915mm, 2440mm × 1220mm, thickness 0.6-1.2mm.
Q:who knows the uses of refratories?
Of course, the role of the refractory material is fireproof, generally used in large buildings. It can reduce casualties and economic losses caused by the fire. it also can be used on the chemical instruments. ! !
Q:I wanna ask you, which level is b1 fireproof and thermal inuslation matertial ??
I soppose you mean rubber and plastic! Only rubber and plastic has b1b2 level. Level b1 is the fireproofing level b1, because the rubber and plastic does not belong to the fireproofing material. It only has fire retardant. The wholesale of all kinds of thermal insulation material and construction need to look at the name, hope you adopt.
Q:What's the organzational structure of refractory material?
Although hacing same chemical composition refractory material products also is mineral organizer. There are differences in the type of mineral phase, high refractoriness under load, quantity and crystalline state. The organizing minerals and microstructure are reflected by folding strength, high temperature pit definite density torsional strength, high-temperature torsional strength and product property. But, for example, wear or crack may cause damage. The performance index can reflect the internal structure of refractory: the nature of the thermal performance---linear expansion coeffcient. And the mineral composition of refractory material depends on the chemical composition and process conditions, the heat capacity and temperature conductivity. If the processing conditions are different, the influence of chemical action, and thermal conductivity: represents the nature of the mechanical properties - normal temperature, high temperature compression strength, high temperature creep performance and elastic modulus. Chemical compositions are the basic characteristics of refractory, representing the nature of the density---porosity, corrosion occurred refractory materials in high temperature use As a result, the composition and quantity directly determines the performance of refractory, true density: representing the forming of high temperature performance --- refractoriness, high temperature volume stability, so you can't analyze the effect on the product performance just from chemical composition. The performance of various refractory materials are different. It must be emphasized that macroscopic organization structure of refractory material is also an important factor that affects performance; reflecting complexity of penetration---air permeability, thermal shock resistance and slag resistance. The main component is the foundation of refractory characteristics.
Q:Can I use ordinary cement with the addition of sand, clay, and salt as refractory material to paste the stove?
You can add some animal hair, like bristles. After all, we don’t have so much hair. Remember not to use cement, because it will crack. Instead, make use of animal hair, lime, yellow mud and sand, after mixing up, and they would be firmer while in calcination.
Q:What is the interior fireproof thermal insulation material?
polystyrene foam board, glass fiber spraying, polyurethane foam, thermal insulation system of inorganic wall. Use "DY" inorganic active thermal insulation material, have small thermal conductivity, large heat storage coefficient, better strength and achieve better thermal insulation and energy-saving effect when used in wall . Wall should definitely not crack and hollow because of high temperature in summer. It doesn't crack and shed because it is influenced by stress during heat expansion and cold contraction in cold winter.
Q:Who knows how to divide the building fire grade and fire resistance grade?
I hope to help you building fireproof rank division is one of the most basic measure in building fire safety technical measures, Building's fireproof rank is divided into class one, two, three, four according to China's architectural design specification. Fire-resistant capability of the highest level is the strongest; Fire resistance of four level of the weakest. The fire resistance level of a building depends on the combustion performance and fire resistance of the building components that comprise the building. The so-called building component refers to a series of basic components, such as wall, foundation, beam, column, floor, stair, ceiling and so on. The judgment condition of the fire resistance There are three conditions for components' fire resistance limit to be reached, namely, the fire resistance limit of the building component: Loss of support and integrity; loss of time to fire the role of the time; as long as any of these three conditions is met, it will reach its limit of fire. Hope my answer will help you.
Q:What is the new fireproofing standard of external wall thermal insulation materials?
The new national standard "Fireproof  Specification of Building Design" (GB50016-2014) has been issued, it will be carried out from May 1, 2015. Compared with "Fireproof  Specification of Building Design" GB 50016-2006 and "fire safety rules of tall buildings design" GB 50045-95 (2005 edition), the major changes of new standard is the following: 1. It has combined with "Fireproof  Specification of Building Design" and "Fireproof  Specification of Tall Buildings Design", and has adjusted incompatible requirements between two standards, and has unified the classification of residential buildings in accordance with the building height; 2. It has increased two chapters including the fire-fighting rescue facilities and wooden structures, and has improved the requirements for fire fighting and rescue, and standardized the fireproofing requirements of wood construction; 3. Additional requirements for the fireproofing requirements of building external insulation system; 4. The fire-fighting equipment is written in a separate chapter and improve relevant contents; cancel the design requirements of fire water supply system and smoke control system, and they are regulated by the relevant national standards; 5. appropriate increase in the high-rise residential buildings and fireproofing technical requirements for high-rise civil building whose height is greater than 100m; 6. add the fireproofing requirements used by covered pedestrian during evacuation; adjust and add designers density of construction materials, furniture, lighting shops and exhibition hall; 7. add the fireproofing requirements of underground warehouses, logistics buildings, large combustible gas tank (zone), ammonia storage tanks, LNG storage tank, and adjust the fire separation distance of liquid oxygen tank; 8. improve the relevant requirements to prevent vertical or horizontal spread of building fire.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range