CDLK/CDLKF Non-selfpriming Designed Multi-stage Centrifugal Pumps

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
2000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Description
CDLK/CDLKF is non-self priming multi-stage centrifugal pump installed with standard motor.The motor shaft is directly connected with the pump shaft through
coupling.According to the requirement,the pump can be equipped with intelligent protector,which effectively protects pump from dry rotation,phase lack,overload etc.In order to meet the requirement of installation depth of the water tank or vessel,it is possible to install cavity body for changing length of the pump.Length for different number of stages is shown in the dimensions & weight table and the table of products supplying scope. 

 

2. Application

Electric spark 
Lathe 
Grinding machine 
Processing center 
Cooling devices 
Industrial clearing equipment 
Filtering system 

3. Performance range
Capacity: Q up to 55 m3/h 
Head: H up to 305m 
Temperature: T up to 120degreeCelsius 
Speed: N 2900/3500rpm 
Power: P up to 45kw 

4. Standard material
Stainless steel 304 or Stainless steel 316 
The pump head and suction & discharge head can be made of cast iron on request too. 

5. FAQ

1>.  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2>.  Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3>.  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

4>Can your pumps mount Eff.1 motors

Currently, only on request though this will shortly be a CNBM standard.

5>Are your pumps protected against dry running?

No, unprotected centrifugal pumps are not generally designed for dry running. It is important to give us or your dealer as much information as possible about the system in which the pump is used. Inlet pressure, the type of liquid to be pumped, together with relative density, viscosity and temperature, for example, are required in order to allow CNBM to recommend the right pump with the right gaskets for a long operating lifetime.

6>How can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

CDLK/CDLKF Non-selfpriming Designed Multi-stage Centrifugal Pumps

CDLK/CDLKF Non-selfpriming Designed Multi-stage Centrifugal Pumps




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Is the centrifugal pump large or small?
Centrifugal pump, the smaller the better the cavitation.1, centrifugal pump cavitation less, anti cavitation performance is better, the pump cavitation is called the necessary cavitation margin or pump inlet dynamic pressure drop, the smaller the better. Generally speaking, the pump cavitation is the need for cavitation, the pump inlet pipe said effective cavitation margin, that is, the device cavitation margin. For a given pump, at a given speed and flow rate required NPSH is called pump necessary NPSH, also called NPSH, is required to achieve the performance parameters of the pump cavitation, the internal flow and the centrifugal pump is composed of pump head itself, its physical meaning is that liquid drop in pump inlet pressure part degree, is to guarantee the pump cavitation does not occur, with surplus energy exceeds the vaporization pressure head at the inlet of the pump unit weight of liquid. The cavitation must be independent of the device parameters. It is only related to the parameters of the inlet of the pump. These parameters are determined by the geometric parameters at a given speed and flow.
Q:How to install, operate and maintain the pipeline booster pump?
When the pump leaks, check it immediately to prevent leakage. If it leaks with the motor connection, replace the mechanical seal. Check that the power is connected. Is the supply voltage consistent with the operating voltage of the pump?. If the above a and B are normal, please remove the pump, open the pump cover, remove the foreign body in the pump, and then pump the lid on, and then tighten it to normal.No water pump, pump installed in the tap water pipeline, such as tap water level in the pump impeller on the plane (horizontal installation) or center line (vertical) below, you should turn off the power supply, to tap water level rise more than the impeller plane or the center line, connected to the power supply, to avoid mechanical damage (automatic no need to turn off the electric type). When the pump used in pumping wells, please check whether the water inlet pipe leak; pump cavity storage is not enough, should be filled with water, whether the suction process is too high, proper adjustment. Check whether the inlet and outlet diameter is too small or blocked. Automatic type after a period of time, there may be automatic failure phenomenon, mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging, can be re used.
Q:What does electromechanical vector pump mean?
It is a close set of mechanical and microelectronic technology. It adopts dual control center mode to control, and has a new water pump with logic control center and IPC control center.
Q:Why adjust the centrifugal pump outlet valve can adjust the flow?
This method can be used to regulate flow. The advantage is that it is simple and easy to use and the disadvantage is that the throttle consumes energy
Q:Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines?
Submersible pump is best in the water, if dry pumping will cause burns.
Q:60 type concrete pump performance?
HBT60.13.90S performance parametersParameter name unit HBT60.13.90SMaximum theoretical concrete conveying capacity m3/h 69/43Maximum pump outlet pressure Mpa 13/7
Q:What are the ways of hydraulic pumps?
There are several ways:Direct flow mode, such as external gear pump;Port plate, such as vane pump, axial piston pump, etc.;
Q:What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
Suction is allowed to pump the vacuum from the distance from the inlet, which is part of the field installation.The manufacturer of cavitation allowance is closely related to the design and process of pump. Estimation formula: cavitation allowance =10.33 meters - allow suction of -0.5 meters (safety).
Q:What does "anti pump" mean in pump operation?
The pump again is the pump, the theory is the plugging problem can be solved, but if you are against the pump after pump has been plugging serious, and pump has been unable to solve the plugging problem, finally the worst solution is a split pipe, if the situation under enormous pressure will only exacerbate the plugging
Q:Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
What is straight pump and non direct pump? Direct coupled pump shaft and the motor shaft is directly coupled with the coupling and non direct coupled pump: pump shaft and motor shaft through the belt pulley, V-belt connection or other forms of transmission. What is the difference in the structure: the direct coupled pump has the advantages of compact structure, simple installation, but the relatively small power; non direct coupled pump: pump and motor is independent, the two transfer torque through the belt, the structure is relatively large, complex installation, general power is relatively large.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range